67
Turbine Station Configuration Guide
A100K11194
Dak Released
-
If enabled, the station will send an SNMP trap when a DAK is released.
Relay Activated
-
If enabled, the station will send an SNMP trap when a relay is activated.
Relay Deactivated
-
If enabled, the station will send an SNMP trap when a relay is deactivated.
Button Hanging
-
If enabled, the station will send an SNMP trap when a button is hanging.
Sound Test Failed
-
If enabled, the station will send an SNMP trap when a sound test has failed.
Sound Test Error
-
If enabled, the station will send an SNMP trap when there is a sound test error.
Sound Test Success
-
If enabled, the station will send an SNMP trap when a sound test is successful.
Input Button Pressed
-
If enabled, the station will send an SNMP trap when an input is activated.
Input Button Released
-
If enabled, the station will send an SNMP trap when an input is deactivated.
Software Fault
-
If enabled, the station will send an SNMP trap when software daemon has stopped working.
8.2 Network Access Control
IEEE 802.1X is an IEEE Standard for Port-based Network Access Control (PNAC). It provides an
authentication mechanism to devices wishing to attach to a LAN, either establishing a point-to-point
connection or preventing it if authentication fails.
802.1X Network Access Control is configured from the IP station web interface.
● Select
Advanced Network
>
802.1X
The radio-button list lets the user choose the authentication method to configure.
Summary of Contents for ECPIR-3P
Page 1: ...TECHNICAL MANUAL Turbine IP Intercoms TCIS TCIV TFIE TFIX TMIS ECPIR 3P A100K11194 PRE 14 0029...
Page 22: ...22 A100K11194 Turbine Station Configuration Guide 3 6 Turbine Relay Module TA 10...
Page 77: ...77 Turbine Station Configuration Guide A100K11194 A 6 Front Board Front A 7 Front Board Rear...