flowSCREW 4w
packages
Copyright Vincotech
Handling Instruction
03
rem. sect. 5.2; mod. at sect. 5.1 29.09.2014
Gyimóthy Zs.
Gyetvai T.
FSWB-M-*-HI
Page
11 /
18
02
remove section 6.2
14.05.2014
Gyimóthy Zs.
Gyetvai T.
01
20.02.2014
Gyimóthy Zs.
Gyetvai T.
Ver.
Alteration
Date
Des. / Mod.
Appr.
7 Screw specification for fastening main terminals to bus bars
M6 screw: The threaded hole's depth in the module is 12 mm max. from the main
terminal's topside. (See the outline drawing for detailed dimensions.)
Mounting torque: 2.5 Nm < Ma < 5 Nm
Flat washer: ISO 7092 (DIN 433)
Spring washer: DIN127 or DIN 128
8 flowSCREW 4w modules in parallel mode
8.1 Mounting the M4 hex nut-holder for side connection
Push in the M4 hex nut-holders from the side of the module and clip the mounting clips into the
PCB cutouts (see
Figure 10
). The shape of the cutout may vary for different PCB thicknesses.
M4 hex nut: The hole's depth in the holder is 8 mm max. from the module's topside. (See the
outline drawing for detailed dimensions.)
Figure 9: Mounting an M4 hex nut holder