8
TAB: 7559
EN
Installation
Important:
The device should be installed at a height of
approximately 160 cm off the floor, taking care not to expose it
to direct sources of light so as to avoid annoying glare on the
surface of the LCD screen
Note
: Fig. 1 shows the recommended installation distances,
unless otherwise specified by current regulations.
1. Secure the plate to the wall, with metal bracket, in box:
circular 2M (Vimar V71701), 3M (Vimar V71303, V71703)
vertical and square British standard.
2. Wire the terminal block (Fig. 4).
3. Terminate the video signal (Fig. 4)
4. Install the video entryphone as follows: position the video
entryphone on the plate keeping it slightly raised. While
keeping the front panel pressed, apply a light downward
pressure until it clicks into place.
5. Should you need to remove the monitor you need to apply
a light pressure on the lever (Fig. 3) and raise it (from
the bottom upwards) so as to release the monitor from
the chassis.
Fig. 1
1,20m
1,60 / 1,65m
> 10 cm
Fig. 3
Fig. 2