OPERATION
When switched on for the first time (assigning ID of internal devices) the separator 949S allows the transit of 4- or 8-digit commands together with the voice lines
between internal and external in order to facilitate internal programming. Once all the internal IDs have been assigned, the separator or the various separators
inserted in the system must be programmed as the initial user and final user connected to them. Programmed in this way by sending a call which is within the
range (initial user - final user), the voice line relay of the separator is connected so as to allow the transit of both the call and the voice line towards the calling
panel. Note that the monitors equipped with an internal generator (series 6600) ring even if they are not within the range (initial user - final user) but as regards
the voice line they are not connected to the entrance panel. Once activated, the separator is reset either for another call or at the end of the call. The device
repeats all the digital commands that it receives from the two serial lines in the opposite serial line.
Table 3. Table summarising the functions
Reception from a downstream serial line (terminal 6), if Initial and Final User
DIGIBUS COMMAND
Description
Operation of the 949S
CALL_TARGA
CALL_TARGA_TLC
CALL_TARGA_INT
CALL_TARGA_T_I
CALL_AUTOACC_TARGA
CALL_AUTOACC_TARGA_TLC
Call from an Audio-Video Panel or Self-start
Within its own Range
RELAY ACTIVATION’
Outside its own Range
RELAY DEACTIVATION
Reset Command
RELAY DEACTIVATION
Ricezione da seriale a monte (morsetto 1),anche se non programmati Utente Iniziale e Finale
DIGIBUS COMMAND
Description
Operation of the 949S
ENTER_PRG
Enter programming of a (video)interphone
RELAY ACTIVATION’
MEM_PRG
Completed programming of a (video)interphone
RELAY DEACTIVATION
REC_NUMBER “*”
Reply of a (video)interphone to a call from the en-
trance panel
RELAY DEACTIVATION
“*” Command not yet operative
DESCRIPTION ART. 949S
Art. 949S is a separator accessory for use in DIGIBUS systems with both 4 and 8 digits to create:
• An electric protection on the power supply.
• A physical separation for the digital line (the commands are retransmitted) and the voice line (normally disconnected from the rest of the system) between
one group of interphones/monitors and the rest of the system.
Power supply: 13.5 VDC
Max. Absorbed Power: 0.5W
The separator is connected in the system between the entrance panel and the group of interphones/monitors to be “protected”. It is possible to install the sep-
arator art. 949S either on the wall or on a DIN rail. (see Fig.1).
This accessory is used only for internal devices with a decoder on board.
Table 1
LED - 1
LED - 2
CURRENT
GENERATOR
JUMPER
Terminal Description
5i
Input power supply of the (video)interphone riser
4
Earth Reference
1
Digital line to (video)interphones
6
Digital line from the (video)interphone riser
3
Voice line to (video)interphones
8
Voice line from the (video)interphone riser
5
Power supply to (video)interphones
Table 2
Pushbuttons - Led – Connectors
Pushbutton
S1
For programming
Pushbutton
S2
For programming
Led
LED-1
Led for debug and programming
Led
LED-2
Led for debug and programming
Jumper
GE
Current Generator Jumper
EN
The instruction manual is downloadable from the site
www.vimar.com
Fig. 1
EN