background image

Viale Vicenza, 14

36063 Marostica VI - Italy

www.vimar.com

49400573B0  02  1702

Eikon TACTIL

21119

Electronic control with N/O relay output 6 A 230 V~, can be activated locally or from different 
points with remote controls or N/O push buttons, programmable monostable or bistable 
operation, visible in darkness, power supply 230 V~ 50-60 Hz, to be completed with Eikon 
Tactil cover plate and label.

FEATURES.

• Rated supply voltage: 230 V~, 50/60 Hz
• Mains power draw: 10 mA, 230 V~ 
• Indicator lights with interchangeable symbols for identification in the dark
• Touch button recalibration: 1 minute
• Operating temperature: -5°C - +35°C 

CONTROLLABLE LOADS.

• Resistive loads 

: 6 A.

• Incandescent and halogen lamps 

: 1000 W.

• Ferromagnetic transformers 

: 1000 VA.

• Electronic transformers 

: 700 VA.

• Fluorescent and compact fluorescent lamps: 60 W.
• Motors  : 1.8 A cos   0.6.
• LED lamps: 60 W
If installing 2 or more switches in a single box, the loads controlled by each switch must be reduced 
so that their total does not exceed the values indicated above.

OPERATION.

• Front indicator lights: always on
• Controls:
- touch control on the front; lightly place a finger on the light on the front of the device to actuate 

the control.

- operation from several positions using remote control 21122 or N/O buttons (maximum range 100 

m); 

do not use buttons with integral indicator light

 

- if you select the button function, the load is only active while pressing the top button.
• The buzzer is always enabled when configuring.

N.B: In the event of a mains power failure the device's relay will always go onto NO.

Each time the cover plate is installed, wait at least 1 min. for it to be recalibrated. 

CONFIGURATION.

With the load/lamp switched off, press both buttons under the cover plate simultaneously. The top 
button will start blinking and enter configuration phase 1: 
- tap on the 

bottom

 

button

 to change the settings of the selected configuration

- tap on the 

blinking top button

 to save the selected phase and move on to the

next phase of configuration.

If no operations are performed within 15 s, the device will exit the configuration without saving the 
last phase.

CONFIGURATION

SETTING

PROCEDURE

Top button LED

Bottom button LED

PHASE 1
Change brightness

 

             

1 repeated blink

Always on

at the set brightness

Press the bottom button to 
change the brightness cycli-
cally (low, medium, high)

PHASE 2
Enable buzzer

2 repeated blinks

Buzzer off

Buzzer on 

Press the bottom button to 
switch the buzzer on/off

PHASE 3

Enable flashing LED 
with relay active to 
control load outside 
the door

3 repeated blinks

Blinking disabled

Blinking enabled

Press the bottom button to 
enable/disable the blinking 
function

PHASE 4
Enable 
button

4 repeated blinks

Button disabled

Button enabled

Press the bottom button to 
enable/disable the push-
button function

PHASE 5
Enable time 
switch

5 repeated blinks

Timing off

Timing on

Press the bottom button to 
enable/disable rocker button 
timing

PHASE 6
Change
timing

6 repeated blinks

Initially off

Start of timer 

(1s - 5 min)

Press the bottom button to 
start the timer; when the lower 
LED is on and the desired time 
has elapsed, 

press the top 

button to save the timing.  

  

LED on 

 

        

  LED blinking 

 

  LED off (default) 

  

 

 

 

FRONT AND REAR VIEW

LED

top

button

LED 

bottom

button



L

N

CONNECTIONS

N/O push-buttons

For all details on possible installation architectures, please refer to SI-Installation Diagrams for the 

relevant item code at www.vimar.com -> Products -> Product catalogue.

INSTALLATION

1. 

2.   

3. 

4.   

INSTRUCTIONS.

Connect the appliance as indicated in the "CONNECTIONS" illustration. The power circuits (L-N) 
should be protected against overloading by installing a device, fuse or circuit breaker, with rated 
current not exceeding 10 A.

INSTALLATION RULES.

Installation should be carried out in compliance with the current regulations regarding the instal-
lation of electrical systems in the country where the products are installed.   
• The device can be installed Eikon Tactil cover plates with 2, 3 and 4 modules; use the dedi-

cated blank module art. 21041 to close the unused modules. 

• When installing with a BS 5M cover plate (2+blank+2), thus on the mounting frame art. 20609, 

the device cannot be installed in the central module of the mounting frame; this module 
should be closed by using the blank module art. 21041 (for details, see

 SC-Card on www.

vimar.com -> Products -> Product Catalogue

 at the article code). 

• On the same cover plate used for art. 21119 it is not possible to install SELV Tactil devices 

(art. 21520, 21540, 21840, 21860).   

REGULATORY COMPLIANCE.

LV directive. EMC directive. 
Standard EN 60669-2-1.

Reviews: