Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49400481A0 03 1804
Eikon
20547
Arké
19547
Idea
16987
Plana
14547
Three rocker push buttons and actuator for 1 roller blind with 8 A relay
output, to complete with 1 or 2-module buttons – 3 modules.
Device to be used as three single buttons or one single and one double, depending
on the button.. It can be configured independently from the actuator too. It can be
pressed both at the top and at the bottom.
CHARACTERISTICS.
• Rated supply voltage: BUS 29 V
• Input: 25 mA
• Relay output
• Controllable loads at 120-230 V~:
- resistive loads: 8 A (20.000 cycles)
- motors cos ø 0.6: 3,5 A (100.000 cycles)
• Button: double or single
• Terminals:
- TP bus
- relay contacts (C, 2, 1)
• Possible functions:
- ON/OFF switch
- roller shutter control
- dimmer control
- activation of 2 scenarios.
•
Consist with By-me flush and surface mounting control units, rel.2.0 and next
and By-me 2-module control units, rel. 2.0 and next
CONFIGURATION.
FOR THE OPERATIONS OF INSTALLATION AND CONFIGURATION, SEE THE
By-me SYSTEM INSTRUCTIONS MANUAL ATTACHED TO THE CONTROL UNIT.
Configuration must be done with the device without the key to be able to press the
central configuration button. The device can be used as three single buttons or one
double push-button and a single one.
• Functional blocks: 4 (3 buttons, 1 roller shutter actuator), each functional block can
belong to at most 4 groups.
• Selecting the functional block (configuration): during group creation, when the con-
trol unit requires pressing the device button:
- press the configuration button;
- if the device must be configured as three single push-buttons, within 3 s, press the
right-hand button to select the right functional unit, the middle button to select the
middle functional unit or the left-hand button to select the left functional unit; the red
LED illuminates. If none of the three buttons is pressed within approximately 3 s the
red LED will light up; in this case the functional block selected is the 4th, referring
to the actuator.
- if the device must be configured used as a double and a single push-button, pro-
ceed as follows:
• configure the left functional unit in the case in which you want a push-button with
two modules on the left of the device (left middle button) and then configure
the right functional unit (right button);
• configure the middle functional unit in the case in which you want a push-button
with two modules on the right of the device (middle right button) and then
configure the left functional unit (left button).
- with the red LED on, the control unit will configure the functional block; at the end
of this operation the red LED will go out.
When the device is not configured, the actuator is controlled by the left-hand button.
PARAMETERS.
• For the functional blocks related to tree two buttons it is possible to set the operating mode:
- ON/OFF button;
- dimmer control button;
- roller shutter control button;
- scenario control.
• Operation as a dimmer control button:
- pressing the key at the top for less than 0.5 s lights up the load with the dimming at
the saved point;
- pressing the key at the top for more than 0.5 s increases brightness until it is released;
- pressing the key at the bottom for more than 0.5 s decreases brightness until it is released;
- pressing the key at the bottom for less than 0.5 s switches off the load.
• Operation as a roller shutter control button:
- pressing the key at the top for more than 0.5 s opens the shutter completely; it stops
when fully open or when briefly pressing the key (either at the top or bottom);
- pressing the key at the bottom for more than 0.5 s closes the shutter completely;
it stops when fully closed or when briefly pressing the key (either at the top or bottom);
- use only roller shutters with a built-in limit switch.
• LED parameters:
- LED off;
- LED with normal operation (on if the associated actuator is ON);
- LED with reverse operation;
- LED always on for location in the dark;
- central LED with normal operation (Double button);
- central LED with reverse operation (Double button);
- central LED always on for location in the dark (Double button).
If the functional block belongs to more than one group, the “LED with normal
operation” and “LED with reverse operation” parameters are not available. In
these cases the control is confirmed by a LED status change for 3 s. If a double
key is used, it is necessary to set the central LED behaviour to make the status
visible. In this case, configure the left button if the double button is on the left of
the device or the middle button if the double button is on the right.
• Functional block 4, related to the roller shutter actuator:
- on delay on reception of a scenario command from 0 to 250 s in steps of 1 s;
- on delay on command from 0 to 250 s in steps of 1 s.
- off delay on command from 0 to 250 s in steps of 1 s;
• Default parameters: the two keys are enabled as a shutter control and LED in
normal operation; shutter actuator with null on and off delay. The buttons are set
as ON/OFF push-buttons.
SCENARIOS.
Each tilt button can be dedicated to activating one or two scenarios. The actuator
can belong to multiple scenarios and, for each one of them, save the status to retrieve
when activating the scenario. For further details see the control panel manual. The
saved status can only be either shutter fully open or fully closed.
INSTALLATION RULES.
• Installation should be carried out by qualified personnel in compliance with the
current regulations regarding the installation of electrical equipment in the country
where the products are installed.
• The feeding circuit of the relay output must be protected against overloads by a
device, fuse or automatic circuit breaker, with rated current not higher than 10 A.
For further instructions, please see the manual attached to the control panel.
CONFORMITY.
LV directive. EMC directive.
Standard EN 50428.
Terminals
bus TP
Configuration button
120-230
8
C
2
1
VISTA FRONTAL Y TRASERA.
Led
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the
product must not be included with other general waste at the end of its working life. The
user must take the worn product to a sorted waste center, or return it to the retailer when
purchasing a new one. Products for disposal can be consigned free of charge (without
any new purchase obligation) to retailers with a sales area of at least 400 m
2
, if they
measure less than 25 cm. An efficient sorted waste collection for the environmentally
friendly disposal of the used device, or its subsequent recycling, helps avoid the potential
negative effects on the environment and people’s health, and encourages the re-use and/
or recycling of the construction materials.