7
Note:
Take care to write down all the IDs assigned to the interfaces 01729 because later on, when configuring
via the keypad or By-alarm Manager software, you will have to associate the same value. Depending on the ID
assigned and the selection for the 8 or 16 radio Inputs, the control panel will assign 8 or 16 zones according to
the numbering that depends on the presence of other interfaces 01729 and input expansion modules 01709-
01704 and the IDs assigned to them.
If the zones supported by the By-alarm control panel are exceeded (24 for 01700 and to 64 for 01703), the
inputs, even if configured, are ignored.
6. Supervision
The supervision mechanism is based on periodically sending data packets from each single device to the radio
interface.
Since the data packet sent from the device also contains a unique identification code, each single transmission is
also interpreted as a survival message.
For obvious reasons, the remote controls are not subject to supervision.
6.1 How to program Supervision
a. Set the
DIP-switches 2
and
3
to
ON
and the display will show
SU
(supervision).
b. Press the
SELECT
button to display the state of supervision.
c. Press the
PROG
button to deactivate -
NO-
or activate
-yes-
supervision.
d. At the end, set the
DIP-switches 2
and
3
back to
OFF
.
6.2 Supervision operation
After the phase of installing the devices, the radio interface starts supervision control.
After each transmission, the device starts a timer lasting 8 or 20 minutes (the duration varies according to the
programming done on the device); when this time elapses, the device sends a survival message and expects
a confirmation message from the radio interface.
If the radio interface does not receive the expected message, the control panel signals the situation of failing
to send the Supervision communication for that device.
By-alarm
Supervision