Vimar By-alarm 01728 Manual Download Page 5

Viale Vicenza, 14

36063 Marostica VI - Italy

www.vimar.com

49400927C0  02  1911

By-alarm

01728

The three LEDs will emit a fast blink and then go out; this indicates access to Menu 
1. Lastly, release the 

PROG

 button.

Selecting the desired menu 

To select the desired menu, briefly press the 

PROG

 button; each time it is pressed 

the LEDs change status, showing the related menu item as shown in the table 
below:

LEDs on 

Descriptions of the menu

R

G

V

Menu 1 

- IN and Tamper configuration

Menu 2

 - Pyroelectric configuration 1

Menu 3

 - Pyroelectric configuration 2

 

Menu 4

 - Channel configuration

Menu 5

 - Supervision and LEDs configuration

 

Menu 5 

- Transmission capacity configuration

Legend: 

R

=Red LED,

 

G

=Amber LED, 

V

=Green LED.

N.B.

 In the following contents the default configuration is indicated by 

*

.

The R and V LEDs display the selectable options and the G LED, activated/
deactivated with the TAMPER button, confirms the selected one.     

   

 Menu 1 

When 

all LEDs are off

 you are in Menu 1.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 - Using the 

TAMPER

 push-button to edit and the 

PROG

 push-button to scroll 

through the options, set the desired function as shown in the table below:

LEDs on 

Amber LED off

Amber LED on

R

V

IN: NC (normally closed)

*

 

IN: NO (normally open)

Tamper off

*

 

Tamper on

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

 Menu 2

When the 

amber LED is on 

you are in Menu 2.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 - Using the 

TAMPER

 push-button to edit and the 

PROG

 push-button to scroll 

through the options, set the desired function as shown in the table below:

LEDs on 

Amber LED off

Amber LED on

R

V

Pyroelectric off

*

 

Pyroelectric on

Blind Time: 4 min

*

 

Blind Time: 2 min

N.B.

: Blind Time is the period of suspension of pyroelectric detection so as to 

optimise energy saving. This period of suspension is activated when an alarm 
is detected and ends at the end of the programmed time.

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

 Menu 3

When the 

green LED is on 

you are in Menu 3.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 -  For this menu, only one of the functions must be active; using the 

PROG 

button, scroll through the options until you find the desired configuration and 
press the 

TAMPER

 button to confirm the choice that 

will be highlighted by the 

amber LED coming on

LEDs on 

Functions

R

V

1 pulse

*

 

2 Bipolar pulses

3 Bipolar pulses

4 Pulses of any polarity

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

 Menu 4

When the 

green and amber LEDs are on 

you are in Menu 4.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 -  For this menu, only one of the functions must be active; using the 

PROG 

button, scroll through the options until you find the desired configuration and 
press the 

TAMPER

 button to confirm the choice that 

will be highlighted by the 

amber LED coming on

LEDs on 

Functions

R

V

*

 

In IN: all on channel 1

Infrared: on channel 1
IN: on channel 2

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

 Menu 5

When the 

red LED is on 

you are in Menu 5.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 - Using the 

TAMPER

 push-button to edit and the 

PROG

 push-button to scroll 

through the options, set the desired function as shown in the table below:

LEDs on 

Amber LED off

Amber LED on

R

V

Supervision off

*

 Supervision on

Supervision interval 8 min

*

 

Supervision interval 20 min

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

 Menu 6

When the 

red and amber LEDs are on 

you are in Menu 6.

 - Press the 

SELECT

 push-button to enter the configuration; the three LEDs will 

blink 3 times to confirm the selection made.

 -  For this menu, only one of the functions must be active; using the 

PROG 

button, scroll through the options until you find the desired configuration and 
press the 

TAMPER

 button to confirm the choice that 

will be highlighted by the 

amber LED coming on

LEDs on 

Functions

R

V

Normal power

Medium power

Maximum power

- To save and return to the main menu, press the 

SELECT

 button; to save and exit 

configuration completely, briefly press the 

RESET

 button.

Summary of Contents for By-alarm 01728

Page 1: ...nni successiva a quella della sostituzione ATTENZIONE Pericolo d esplosione in caso di batteria sostituita con altra di tipo scorretto CONFIGURAZIONE DEL RIVELATORE La programmazione del dispositivo prevede la configurazione di diversi parametri che riguardano il funzionamento del rivelatore dell ingresso filare di cui esso è dotato della supervisione e dei led E inoltre necessario definire come d...

Page 2: ...ed verde acceso indica che ci si trova sul Menù 3 Premere il pulsante SELECT per entrare in configurazione i tre led lampegge ranno per 3 volte a conferma delle selezione effettuata Per questo menù solo una delle funzioni deve essere attiva con il pulsante PROG scorrere le opzioni fino a trovare la configurazione desiderata e premere il pulsante TAMPER per confermare la scelta che verrà evidenziat...

Page 3: ...elettrico in vigore nel paese dove i prodotti sono installati Il rivelatore deve essere installato ad un altezza di 2 2 4 m dal pavimento CONFORMITA NORMATIVA Direttiva RED Norme EN 60950 1 EN 50130 4 EN 61000 6 3 EN 301 489 3 EN 300 220 2 EN 62479 Vimar SpA dichiara che l apparecchiatura radio è conforme alla direttiva 2014 53 UE Il testo completo della dichiarazione di conformità UE è disponibil...

Page 4: ...le uses 1 external contact Operating temperature 10 40 C Dimensions 110x60x46 mm CONNECTIONS FOR EXTERNAL CONTACT The terminal block shown below enables connecting external devices such as for instance an external magnetic contact IN input 1 of the external magnetic contact configurable as normally closed or open common negative input BATTERIES The detector is powered by a 3 V CR123 lithium batter...

Page 5: ...u are in Menu 3 Press the SELECT push button to enter the configuration the three LEDs will blink 3 times to confirm the selection made For this menu only one of the functions must be active using the PROG button scroll through the options until you find the desired configuration and press the TAMPER button to confirm the choice that will be highlighted by the amber LED coming on LEDs on Functions...

Page 6: ...d out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed The detector should be installed at a height of 2 2 4 m off the floor REGULATORY COMPLIANCE RED directive Standards EN 60950 1 EN 50130 4 EN 61000 6 3 EN 301 489 3 EN 300 220 2 EN 62479 Vimar SpA declares that the radio equipment...

Reviews: