Technical data
Flush volume 0.8 / 2 / 3 / 4 l (at 3
bar)
Detailed settings via app
(optional)
Hygienic rinse on / off
Detailed settings via app
(optional)
Stadium mode on / off
Detailed settings via app
(optional)
Base sensitivity low / normal
Also via app
Minimum usage duration 9 / 7 / 5
/ 3 sec
Also via app
Hybrid mode on / off and
intervals 1 / 3 / 6 / 12 / 24 / 48
hour
Also via app
Reset to factory settings
Also via app
Setting functions:
(Factory setting bold)
Cleaning/block mode (on / off)
Only via app
Protection class of
electronics
IP 64
Dust-tight, protection
from water spray from
all directions
Sensor function
Detection of urine flow in the
urinal
Sensor principle
HF Sensor 5.8 GHz
Switching power supply unit
•
Primary: 100-240V, +/- 10%,
50 - 60 Hz
•
Secondary: 12V DC, 1A
Power supply (variants)
Battery 6 x 1.5V alkaline (type
AA / LR6)
Service life of battery
approx. 3 years / 200,000 flushes