8
Component Specifications
Switch, refrigerator light
Type
SPST, NC
(Right opening door hinge)
Volt
125 / 250 VAC
Current 3
Amps
Switch,
power
Type
DPST
Volt
125 / 250 VAC
Current 15
Amps
Switch, freezer light, sealed
Type
SPST, NC
Volt
125 / 250 VAC
Current 5.0
Amps.
Switch,
showroom
Type
SPDT
Volt
125VAC
Current 6
Amps
Thermister
Check resistance across
Terminals. Bell curve
Resistance (see page 13)
@77
°
F 30,000
ohms
±
1% ohms
@45
°
F 68,000
ohms
±
2% ohms
Thermostat Volt
120VAC
Watt
1000
Watts
Current 10
Amps
Resistance
across
terminals
Above
55
°
F
±
6
°
F Open
Below
20
°
F
±
8
°
F Closed
Between
55
°
F
±
6
°
F
And
20
°
F
±
8
°
F
Will stay in current state (either
Open or closed) until either 55
°
F
±
6
°
F and 20
°
F
±
8
°
F is reached.
Valve,
water
Volt
120VAC,
60Hz.
Watt
20
Watts
Water pressure (inlet)
Max
120psi
Min
20psi
Fill
rate
140
±
10 CC’s at 7.5 seconds.