![Viking VCBB360L Service Manual Download Page 54](http://html.mh-extra.com/html/viking/vcbb360l/vcbb360l_service-manual_1025453054.webp)
54
Ice Maker Troubleshooting Chart
Excessive Ice Production
Problem
Action
Shut-off arm not in actuator
Replace shut-off arm in actuator
Deformed Shut-off arm
Replace shut-off arm
Broken shut-off lever or
Replace module
lever bypassing vertical cam
Broken module actuator
Replace module
Hollow Ice Cubes
Low water fill volume
Adjust module screw, clear water path,
or replace water valve
Improper freezer air-flow
Direct air flow away from thermostat
Thermostat out of calibration
Replace thermostat
Apply
alumilasic
Flooding or Ice in Bucket or Freezer
Thermostat out of calibration
Replace thermostat
Apply
alumilastic
Jammed cube stalled in water-fill cycle
Remove cube
Determine reason for stall
Leaky water valve
Replace water valve
Excessive water fill volume
Replace water valve
Motor stalled in water-fill cycle
Replace module
(12:
ejector
position)
Contaminated module
Replace module
Refrigerator or ice maker not level
Level refrigerator or ice maker
Excessive water pressure
Decrease water pressure (20-120 psi) (1.4- 8.2bar)
Shorted and burned module shut-off
Replace module
switch and contacts
Broken locking tab on verticle cam
Replace module
(Stalled in water fill)
Fill-tube not properly positioned in
Reposition fill tube
fill
cup
Fill cup water opening blocked
Replace fill cup
Cubes fall over back of ice maker,
Replace fill cup
melting
in
freezer