Electronic Function Description
WARNING
To avoid electrical shock which can cause severe personal injury or death, disconnect power
to refrigerator using power switch before servicing. Wires removed during disassembly must
be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect power using power switch
Refrigeration and Defrost Component Checks Made at High Voltage Board
Low voltage board input
W1 to D11
approximately -25VDC
E10 to E9 (Neutral) or ground
approximately 120VDC
Compressor/condenser fan motor
“ON” = E4 to E9 (Neutral) or ground
approximately 120VDC
“OFF” = E4 to E9 (Neutral) or ground
Compressor/condenser fan motor
“CLOSED” = R7 to ground
approximately -11VDC
relay
“OPEN” = R7 to ground
approximately -25VDC
Evaporator fan motor relay
“CLOSED” = R8 to ground
approximately -11VDC
“OPEN” = R8 to ground
approximately -25VDC
Evaporator fan motor
“ON” =E2 (Neutral) or ground
approximately 120VDC
“OFF” = E2 (Neutral) or ground
0VDC
Defrost heater
“ON” = E6 to E9 (Neutral) or ground
approximately 120VDC
“OFF” = E6 to E9 (Neutral) or ground
0VDC
Defrost heater relay
“CLOSED” = R9 to ground
approximately -11VDC
“ OPEN” = R9 to ground
approximately -25VDC
Defrost terminator
“CLOSED” =E5 to E9 (Neutral) ground approximately 120VDC
“OPEN” = E5 to E9 (Neutral) or ground
0VDC
DC fan output voltage from
“ON’ = E1 to ground
approximately -25VDC
high voltage board to fresh food fan
“OFF” = E1 to ground
0VDC
or condensate evaporator fan
DC fan input voltage
“ON” =R10 to ground
approximately -11VDC
signal to high voltage board from
“OFF” = R10 to ground
approximately -25VDC
low voltage board for fresh food
fan and for condensate evaporator
Filament voltage at pin 11 and 12 = less than 5VDC