Viking VBCV4238 Installation Instructions Manual Download Page 3

5

PREPARING FOR HOOD INSTALLATION

Plan where the ductwork will be located.  See pages 9-12 for rough-in dimensions.  Install proper-sized duct work, and
roof or wall cap for the type of blower you are using. Adjust your measurements for various heights of ceilings, soffits,
cabinets, or ranges/rangetops.

Roof Cap

7” Round

Duct

Roof Cap

10” Round

Duct

12” Duct Cover
or Soffit

300 or 600 CFM Single Blower

Interior-Power - Typical Ductwork

1200 CFM Single Blower

Interior-Power - Typical Ductwork

Exterior Blower

10” Round

Duct

12” Duct

Cover

or Soffit

12”
(30.5 cm)

900, 1200, or 1500 CFM

Exterior-Power - Typical Ductwork

12”
(30.5 cm)

ELECTRICAL SUPPLY

Run 120 VAC electrical power cable from service panel to installation location.  See “Basic Specifications” on page 3
for the maximum amp requirements.

Top Mounting
Holes

Wood Strip 
(provided locally- 1

1/2”

x

3

/

4”

)

Slot for Wood Strip

Rear Mounting

Holes

1

1

/

2”

(3.8 cm)

3

/

4”

(1.9 cm)

1

13

/

16”

(4.6 cm)

INSTALLING HOOD CANOPY (Indoor/Outdoor VWH Models Only)

Center the wood strip (provided locally - see drawing for dimensions) and attach to wall. Using the slot located on the
backside of the canopy, place the hood onto the wood strip. Secure the hood to strip with mounting screws provided.
Make sure that the wood strip mounting screws are driven into the framing and not just the drywall. Use additional
mounting screws (and wall anchors if necessary) in the other holes.

NOTE:  BECAUSE OF
THE WEIGHT OF THE
HOOD - MAKE SURE
THAT THE WOOD STRIP
MOUNTING SCREWS
ARE DRIVEN INTO THE
FRAMING AND NOT
JUST THE DRYWALL.  IT
MAY BE NECESSARY TO
DRILL ADDITIONAL
HOLES IN THE CANOPY
FOR PROPER
ALIGNMENT.

HEIGHT OF INDOOR HOOD

The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop.  This would
typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor.   The bottom of the
hood should never be more than 72” (182.9 cm) above the floor or more than 36” (91.4 cm) above the countertop.
These dimensions provide for safe and efficient operation of the hood.

24” or 27”

(61.0 cm or 68.6 cm)

36”

(91.4 cm)

30”

(76.2 cm)

ISLAND INSTALLATION

WALL INSTALLATION

36”

(91.4 cm)

30” (76.2 cm) Min.
36” (91.4 cm) Max.

Countertop

30” (76.2 cm) Min.
36” (91.4 cm) Max.

18” (45.7 cm)

18” (45.7 cm)

66” - 72”

(167.6 cm - 

182.9 cm)

66” - 72”

(167.6 cm - 

182.9 cm)

HEIGHT OF OUTDOOR HOOD

The bottom of the hood should be 30”
(76.2 cm) to 36” (91.4 cm) above the grill
surface.  The hood should be installed 4-
1/2” (11.4 cm) plus the distance between
the back trim and surface from the back
wall.  (NOTE:  There is a 3” minimum
clearance from the back trim to non-
combustible surfaces and a 24” minimum
to combustible surfaces.)  This will require
building the hood out from the wall. Any
combustible material used for this purpose
must be covered with locally supplied
stainless steel.  It is also recommended a
backsplash be used with outdoor
installations.

18” 

(45.7 cm)

Canopy

Soffit

DIM “X”

plus 4-1/2” (11.4 cm)

30” (76.2 cm) min.
36” (91.4 cm) max.

DIM “X”

-Min. 3” (7.6 cm) to

non-combustible surface

-Min. 24” (61.0 cm) to
combustible surface

27” 

(68.6 cm)

Countertop

4

Summary of Contents for VBCV4238

Page 1: ... Guide Built In 18 H Hoods Indoor and Outdoor Models Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com ...

Page 2: ...ch as possible The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Check with a qualified and trained installer or local codes for makeup air requirement if any This hood is for residential installation only and is not designed for installation over a commercial product Make sure power is off at the main circuit break...

Page 3: ...HT OF THE HOOD MAKE SURE THAT THE WOOD STRIP MOUNTING SCREWS ARE DRIVEN INTO THE FRAMING AND NOT JUST THE DRYWALL IT MAY BE NECESSARY TO DRILL ADDITIONAL HOLES IN THE CANOPY FOR PROPER ALIGNMENT HEIGHT OF INDOOR HOOD The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the...

Page 4: ...ug in Receptacles are located behind and above control panel INSTALLING HOOD CANOPY VBCV VICV Custom Ventilator Kits Only A B 30 W 27 7 16 69 7 cm 21 7 16 54 5 cm 36 W 33 7 16 84 9 cm 21 7 16 54 5 cm 42 W 39 7 16 100 2 cm 21 7 16 54 5 cm 48 W 45 7 16 115 4 cm 21 7 16 54 5 cm 54 W 51 7 16 130 7 cm 21 7 16 54 5 cm 60 W 57 7 16 145 9 cm 21 7 16 54 5 cm 66 W 63 7 16 161 1 cm 21 7 16 54 5 cm Custom Hoo...

Page 5: ...ilator side ways to lift into canopy then rotate into mounting position 3 Engage tab on ventilator with slot in rough in plate AND engage slot in ventilator with barrel nut on threaded stud 4 Push ventilator towards the back of hood to fully engage 5 Use a long flat head screwdriver to tighten the barrel nut securely 6 Plug the ventilator power cord into the receptacle located on the topside of th...

Page 6: ...r Kit 900CFM also see instructions supplied with ventilator kit 1 Locate the blower on the rear slope of the roof Place it in a location to minimize duct run The location should be free of obstacles T V leads electrical lines etc Bear in mind if the blower top is level with the roof peak it will not be seen from the street Keep this approximate location in mind as you work from within the attic 2 ...

Page 7: ...LATOR Exterior Power Ventilator also see instructions supplied with ventilator kit 1 Locate the blower on the rear slope of the roof Place it in a location to minimize duct run The location should be free of obstacles T V leads electrical lines etc Bear in mind if the blower top is level with the roof peak it will not be seen from the street Keep this approximate location in mind as you work from ...

Page 8: ...24 30 36 42 W Models 4 5 8 11 7 cm B 5 8 1 6 cm B 12 30 5 cm Cutout for 10 25 4 cm duct 7 17 8 cm dia Duct Location Note Dotted Line represents cutout 120 V FOR 300 600 or 1200 CFM INTERIOR VENTILATOR INSTALLATION 24 61 0 cm or 27 68 6 cm 18 45 7 cm 1 1 2 3 81 cm 7 8 2 22 cm 9 22 9 cm Transition VIV1200 Only 9 3 4 24 8 cm 14 EXTERIOR VENTILATOR DIMENSIONS 10 Dia 203 4 52 7 cm 241 2 62 2 cm 43 4 12...

Page 9: ...71 8 cm 14 1 8 35 9 cm 36 W Models 34 1 4 87 0 cm 17 1 8 43 5 cm 42 W Models 40 1 4 102 2 cm 20 1 8 51 1 cm 5 8 1 6 cm 5 8 1 6 cm 16 A B 24 W Models 23 7 8 60 6 cm 11 15 16 30 3 cm 30 W Models 29 7 8 75 9 cm 14 15 16 37 9 cm 36 W Models 35 7 8 91 1 cm 17 15 16 45 6 cm 42 W Models 41 7 8 106 4 cm 20 15 16 18 2 cm 48 W Models 47 7 8 121 6cm 23 15 16 60 8 cm 54 W Models 53 7 8 136 8 cm 26 15 16 68 4 ...

Page 10: ... cm 9 1 2 24 1 cm 18 1 2 50 cm Cutout for 10 25 4 cm dia 10 25 4 cm dia Duct Location 120 V Note Dotted Line represents cutout 18 48 54 60 66 W Models 1200 or 1500 CFM EXTERIOR VENTILATOR INSTALLATION 30 36 42 48 54 60 66 W Models 1200 CFM INTERIOR VENTILATOR INSTALLATION Note Dotted Line represents cutout C D 30 W Models 28 1 4 71 8 cm 14 1 8 35 9 cm 36 W Models 34 1 4 87 0 cm 17 1 8 43 5 cm 42 W...

Page 11: ...ls 1 2 5 cm 5 8 1 6 cm 5 8 1 6 cm 11 16 1 7 cm 1 1 2 3 8 cm 1 1 2 3 8 cm 27 7 16 69 7 cm including screw heads 28 7 16 72 2 cm 27 7 16 69 7 cm including screw heads 28 7 16 72 2 cm 9 22 7 cm 6 15 2 cm 17 1 4 43 8 cm 11 1 2 29 2 cm EXTERNAL POWER INTERNAL POWER 5 8 1 6 cm 5 8 1 6 cm B B 9 3 8 23 8 cm 9 5 8 24 4 cm 1 3 16 3 0 cm A A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm 18 3 4 ...

Page 12: ...23 22 ...

Reviews: