Viking VBCV4238 Installation Instructions Manual Download Page 10

19

D

C

8 1/4” 

(20.9 cm)

1 1/16” (2.7 cm)

6 7/16”
(16.4cm)

5 15/16” (15.1cm)

3” (7.62 cm)

FOR 900 or 1200 CFM EXTERIOR

VENTILATOR INSTALLATION

36”, 42” W. Models

2 1/2”(6.35 cm)

D

18 3/4” (47.6 cm)

93/8”

(23.8 cm)

9 5/8”

(24.4 cm)

30”

(76.2 cm)

5/8” (1.6 cm)

4 5/8”

(11.7 cm)

9 1/8”

(23.2 cm)

FOR 600 CFM INTERIOR

VENTILATOR INSTALLATION

36”, 42” W. Models

C

120

V

120

V

*Note:  “Dotted Line” (........) represents cutout.

Cutout for 10” (25.4 cm) Duct 

7” (17.8 cm) dia.
Duct Location

9 3/4”(24.8 cm)

C

D

36” W. Models

35 7/8” (91.1 cm)

17 15/16” (45.56 cm)

42” W. Models

41 7/8” (106.4 cm)

20 15/16” (18.18 cm)

54” W. Models

53 7/8” (136.8 cm)

26 15/16” (68.42 cm)

66” W. Models

65 7/8” (167.3 cm)

32 15/16” (83.66 cm)

D

C

FOR 1200 or 1500 CFM EXTERIOR

VENTILATOR INSTALLATION

42”, 54”, 66” W. Models

FOR 1200 or 1500 CFM INTERIOR

VENTILATOR INSTALLATION

42”, 54”, 66” W. Models

9 3/4” (24.8 cm)

8 3/16”
(20.7 cm

)

3” (7.62 cm)

2 1/2”(6.35 cm)

6 5/8” (16.8 cm)

5 15/16”
(15.1cm)

D

C

183/4” (47.6 cm)

5/8” (1.6 cm)

9 3/8” 

(23.8 cm)

83/8”

(21.3 cm)

5 1/2”
(14 cm)

9 1/4” 

(23.5 cm)

9 1/2” 

(24.1 cm)

18 1/2”
(50 cm)

Cutout for 
10” (25.4 cm) dia.

10” 

(25.4 cm) dia.

Duct Location

120

V

*Note:  “Dotted Line” (........) represents cutout.

18

48”, 54”, 60”, 66” W. Models

1200 or 1500 CFM EXTERIOR VENTILATOR

INSTALLATION

30”, 36”, 42”, 48”, 54”, 60”, 66” W. Models

1200 CFM INTERIOR VENTILATOR INSTALLATION

*Note:  “Dotted Line” (........) represents cutout.

C

D

30” W. Models

28 1/4” (71.8 cm)

14 1/8” (35.9 cm)

36” W. Models

34 1/4” (87.0 cm)

17 1/8” (43.5 cm)

42” W. Models

40 1/4” (102.2 cm)

20 1/8” (51.1 cm)

48” W. Models

46 1/4” (117.5 cm)

23 1/8” (58.7 cm)

54” W. Models

52 1/4” (132.7 cm)

26 1/8” (66.4 cm)

60” W. Models

58 1/4” (148.0 cm)

29 1/8” (74.0 cm)

66” W. Models

64 1/4” (163.2 cm)

32 1/8” (81.6 cm)

D

8 1/4” 

(20.9 cm)

6” 

(15.2 cm)

5 1/2” (14.0 cm)

3” 

(7.6 cm)

2 1/2” (6.4 cm)

Cutout for 10” 
(25.4 cm) duct.

D

9 3/8”

(23.8 cm)

9 1/2”

(24.4 cm)

5 1/2”

(14.0 cm)

8 3/8”

(21.3 cm)

9 1/4”

(23.5 cm)

18 1/2”

(50.0 cm)

C

C

10” (25.4 cm)

dia. duct location

5/8” (1.6 cm)

5/8” (1.6 cm)

ISLAND HOOD DIMENSIONS (VIH Models)

FOR 900, 1200 or 1500 CFM EXTERIOR

VENTILATOR INSTALLATION

FOR 600 or 1200 CFM INTERIOR

VENTILATOR INSTALLATION

1” (2.54 cm)

1 1/2”
(3.81 cm)

6” (15.2 cm)

30” (76.2 cm)

30” (76.2 cm)

1 1/2” (3.81 cm)

7/8”
(2.22 cm)

18”

(45.7 cm)

12”

(30.5 cm)

9” 
(22.7 cm)

Transition
VIV1200 Only

Summary of Contents for VBCV4238

Page 1: ... Guide Built In 18 H Hoods Indoor and Outdoor Models Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com ...

Page 2: ...ch as possible The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Check with a qualified and trained installer or local codes for makeup air requirement if any This hood is for residential installation only and is not designed for installation over a commercial product Make sure power is off at the main circuit break...

Page 3: ...HT OF THE HOOD MAKE SURE THAT THE WOOD STRIP MOUNTING SCREWS ARE DRIVEN INTO THE FRAMING AND NOT JUST THE DRYWALL IT MAY BE NECESSARY TO DRILL ADDITIONAL HOLES IN THE CANOPY FOR PROPER ALIGNMENT HEIGHT OF INDOOR HOOD The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the...

Page 4: ...ug in Receptacles are located behind and above control panel INSTALLING HOOD CANOPY VBCV VICV Custom Ventilator Kits Only A B 30 W 27 7 16 69 7 cm 21 7 16 54 5 cm 36 W 33 7 16 84 9 cm 21 7 16 54 5 cm 42 W 39 7 16 100 2 cm 21 7 16 54 5 cm 48 W 45 7 16 115 4 cm 21 7 16 54 5 cm 54 W 51 7 16 130 7 cm 21 7 16 54 5 cm 60 W 57 7 16 145 9 cm 21 7 16 54 5 cm 66 W 63 7 16 161 1 cm 21 7 16 54 5 cm Custom Hoo...

Page 5: ...ilator side ways to lift into canopy then rotate into mounting position 3 Engage tab on ventilator with slot in rough in plate AND engage slot in ventilator with barrel nut on threaded stud 4 Push ventilator towards the back of hood to fully engage 5 Use a long flat head screwdriver to tighten the barrel nut securely 6 Plug the ventilator power cord into the receptacle located on the topside of th...

Page 6: ...r Kit 900CFM also see instructions supplied with ventilator kit 1 Locate the blower on the rear slope of the roof Place it in a location to minimize duct run The location should be free of obstacles T V leads electrical lines etc Bear in mind if the blower top is level with the roof peak it will not be seen from the street Keep this approximate location in mind as you work from within the attic 2 ...

Page 7: ...LATOR Exterior Power Ventilator also see instructions supplied with ventilator kit 1 Locate the blower on the rear slope of the roof Place it in a location to minimize duct run The location should be free of obstacles T V leads electrical lines etc Bear in mind if the blower top is level with the roof peak it will not be seen from the street Keep this approximate location in mind as you work from ...

Page 8: ...24 30 36 42 W Models 4 5 8 11 7 cm B 5 8 1 6 cm B 12 30 5 cm Cutout for 10 25 4 cm duct 7 17 8 cm dia Duct Location Note Dotted Line represents cutout 120 V FOR 300 600 or 1200 CFM INTERIOR VENTILATOR INSTALLATION 24 61 0 cm or 27 68 6 cm 18 45 7 cm 1 1 2 3 81 cm 7 8 2 22 cm 9 22 9 cm Transition VIV1200 Only 9 3 4 24 8 cm 14 EXTERIOR VENTILATOR DIMENSIONS 10 Dia 203 4 52 7 cm 241 2 62 2 cm 43 4 12...

Page 9: ...71 8 cm 14 1 8 35 9 cm 36 W Models 34 1 4 87 0 cm 17 1 8 43 5 cm 42 W Models 40 1 4 102 2 cm 20 1 8 51 1 cm 5 8 1 6 cm 5 8 1 6 cm 16 A B 24 W Models 23 7 8 60 6 cm 11 15 16 30 3 cm 30 W Models 29 7 8 75 9 cm 14 15 16 37 9 cm 36 W Models 35 7 8 91 1 cm 17 15 16 45 6 cm 42 W Models 41 7 8 106 4 cm 20 15 16 18 2 cm 48 W Models 47 7 8 121 6cm 23 15 16 60 8 cm 54 W Models 53 7 8 136 8 cm 26 15 16 68 4 ...

Page 10: ... cm 9 1 2 24 1 cm 18 1 2 50 cm Cutout for 10 25 4 cm dia 10 25 4 cm dia Duct Location 120 V Note Dotted Line represents cutout 18 48 54 60 66 W Models 1200 or 1500 CFM EXTERIOR VENTILATOR INSTALLATION 30 36 42 48 54 60 66 W Models 1200 CFM INTERIOR VENTILATOR INSTALLATION Note Dotted Line represents cutout C D 30 W Models 28 1 4 71 8 cm 14 1 8 35 9 cm 36 W Models 34 1 4 87 0 cm 17 1 8 43 5 cm 42 W...

Page 11: ...ls 1 2 5 cm 5 8 1 6 cm 5 8 1 6 cm 11 16 1 7 cm 1 1 2 3 8 cm 1 1 2 3 8 cm 27 7 16 69 7 cm including screw heads 28 7 16 72 2 cm 27 7 16 69 7 cm including screw heads 28 7 16 72 2 cm 9 22 7 cm 6 15 2 cm 17 1 4 43 8 cm 11 1 2 29 2 cm EXTERNAL POWER INTERNAL POWER 5 8 1 6 cm 5 8 1 6 cm B B 9 3 8 23 8 cm 9 5 8 24 4 cm 1 3 16 3 0 cm A A 8 1 4 21 0 cm 5 3 4 14 6 cm 6 15 2 cm 3 7 6 cm 2 1 2 6 4 cm 18 3 4 ...

Page 12: ...23 22 ...

Reviews: