Viking SO-24A Product Manual Download Page 6

The 

SO-24A

provides balanced 40V talk battery with dial tone on the observing wire pair.  A manager or training

supervisor may access the 

SO-24A

observing port dial tone from an unused trunk input on any PABX/KSU or via

a dedicated Touch Tone phone. The 

SO-24A

may also be remotely accessed through the 

RAD-AMP

Remote Ac-

cess Devices, for more information on the 

RAD-AMP

, see 

DOD# 415

.

A.  Accessing the SO-24A

Once the observing port is accessed, dial any of the twenty-four to two hundred forty lines or stations by dialing
the two, three or four digit dial up code programmed to that station (see Installation chart).  Nothing can be heard
by the station being observed.  Another station may be selected by dialing a “

#

” followed by another two, three or

four digit dial up code.  You may also hang up and then re-access the observing port to dial another dial up code.

B.  Selecting a Line or Station

Though the 

SO-24A

monitors silently, a manager may enter the conversation to provide assistance at any time

by dialing a “

Q

.”  To prevent accidental interruptions, this feature may be disabled (see 

Programming

section 

E

).

C.  Talk Assist

A remotely controllable digital recorder may be started and stopped when interfaced with the 

SO-24A

using the

provided cables (see 

Installation

). To start the recorder, dial a Touch Tone “

9

.”  To stop the recorder, dial a Touch

Tone “

#

” or hang up.

D.  Manually Controlled Digital Recording

6

Applications

Set DIP switch 

3

to 

ON

(see 

Programming

section 

A

) and all monitored conversations will be recorded. If a multi-

module system (Master and Slaves) is installed, set DIP switch 

3

on all modules to 

ON

.

E.  Automatic Tape Recording

The status LED will turn off when a Touch Tone is present from the observing phone, and will wink once per second
while observing a station.

F.  Status LED

Description

Enter Digits

To select another line or station ...........................................................................................

+ new dial up code

To join conversation using talk assist feature .......................................................................

Q

To manually start recorder ....................................................................................................

9

To stop recorder ...................................................................................................................

or hang up

To discontinue observing ..................................................................................................... Hang up

G.  Quick Operation Guide

The 

SO-24A

may be used remotely by adding the 

RAD-AMP

to the monitoring output. 

Important:

When using

this combination, the 

SO-24A

dial up codes can 

NOT

begin with the number 7.  This is because “#7” is the hang-

up command for the 

RAD-AMP

.

A.  Remote Observing

MODEL SO-24A

VIKING

©

24 LINE

SERVICE OBSERVING UNIT

VIKING

ELECTRONICS

HUDSON, WI 54016

POWER

13.8 VAC

STATUS LED

1 2 3

OFF

MASTER
PROGRAM
RECORD CONTROL

RJ21X

LINE / STATION CONNECTIONS

TAPE RECORDER

CONNECTIONS

MULTI-UNIT

COMMUNICATIONS

ON

OFF

INPUT

OUTPUT

RECORD

CONTROL

OUT

AUDIO

OUT

RJ21X Male Jack

(not included)

13.8V AC

Adapter

(included)

RAD-AMP Remote

Access Device

Remote

Observing

Phone

C.O.
Line

LINE OUT

USE ONLY LISTED
CLASS 2 POWER
SOURCE 12V DC
500mA MAXIMUM

LINE IN

REMOTE
SWITCH

Emerson # 66M1-50

Siemon # 66M150

Suttle # SE-66M1-50-C5

To 24 Monitored

Stations or Phones

C.O. Lines

or

24 Analog

PABX/KSU

Stations

Bridge Clip the First 24 Pairs

Punch Down Terminal

Block with Split Center

(not included)

Pins 25 & 50 Tip (V/S)

and Ring (S/V)

Summary of Contents for SO-24A

Page 1: ...a dedicated pair of wires be tween the handset and the SO 24A Monitor stations from an unused phone system line input or to a dedicated single line phone Add remote observing with a RAD AMP Re mote Ac...

Page 2: ...SO 24A W BL BL W W O O W W G G W W BN BN W W S S W R BL BL R R O O R R G G R R BN BN R R S S R BK BL BL BK BK O O BK BK GN GN BK BK BN BN BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BN BN Y Y S S Y V BL...

Page 3: ...X KSU Trunk Port Observing Phone 13 8V AC Adapter included RJ21X Male Jack not included Add up to 8 more SO 24A modules for a total of 240 stations Master Module ON OFF 1 ON OFF 1 DIP Switch 1 must be...

Page 4: ...ON or the only module in a single module system Slave Module s Any module s in addition to the Master module used to increase capacity DIP switch 1 OFF Installation A SO 24A system consists of at lea...

Page 5: ...in section B Enter digits 4 00 Important All SO 24A s in a system MUST be programmed with the same number of dial up code digits The SO 24A is factory set with the dial up codes for locations 1 24 fa...

Page 6: ...Set DIP switch 3 to ON see Programming section A and all monitored conversations will be recorded If a multi module system Master and Slaves is installed set DIP switch 3 on all modules to ON E Automa...

Page 7: ...66M150 Suttle SE 66M1 50 C5 C O Lines RJ21X Male Jack not included or 24 Analog PABX KSU Stations Supervisor 1 Module Bridge Clip the First 24 Pairs Only Punch Down Terminal Block with Split Center n...

Page 8: ...OR RELATED TO THE SALE OR USE OF THE PROD UCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OT...

Reviews: