background image

3

MODEL SO-24A

VIKING

©

24 LINE

SERVICE OBSERVING UNIT

VIKING

ELECTRONICS

HUDSON, WI 54016

POWER

13.8 VAC

STATUS LED

1 2 3

OFF

MASTER
PROGRAM
RECORD CONTROL

RJ21X

LINE / STATION CONNECTIONS

TAPE RECORDER

CONNECTIONS

MULTI-UNIT

COMMUNICATIONS

ON

OFF

INPUT

OUTPUT

RECORD

CONTROL

OUT

AUDIO

OUT

MODEL SO-24A

VIKING

©

24 LINE

SERVICE OBSERVING UNIT

VIKING

ELECTRONICS

HUDSON, WI 54016

POWER

13.8 VAC

STATUS LED

1 2 3

OFF

MASTER
PROGRAM
RECORD CONTROL

RJ21X

LINE / STATION CONNECTIONS

TAPE RECORDER

CONNECTIONS

MULTI-UNIT

COMMUNICATIONS

ON

OFF

INPUT

OUTPUT

RECORD

CONTROL

OUT

AUDIO

OUT

Emerson # 66M1-50

Siemon # 66M150

Suttle # SE-66M1-50-C5

To 24 Monitored

Stations or Phones

C.O. Lines

RJ21X Male Jack

(not included)

or

24 Analog

PABX/KSU

Stations

13.8V AC

Adapter

(included)

Digital Recorder (not included)

Installed on Master Only

(3/32" cable included)

(1/8" cable included)

Unused

PABX/KSU
Trunk Port

Observing

Phone

13.8V AC

Adapter

(included)

RJ21X Male Jack

(not included)

Add up to 8 more SO-24A modules

for a total of 240 stations.

Master Module

ON

OFF

1

ON

OFF

1

DIP Switch 1

must be ON

Master Module

DIP Switch 1

must be OFF

Slave Module

RAD-AMP

Remote Access Device

(DOD# 415)

Remote

Observing

Bridge Clip the 24 Pairs

Bridge Clip the First 24 Pairs

or

Punch Down Terminal

Block with Split Center

(not included)

Emerson # 66M1-50

Siemon # 66M150

Suttle # SE-66M1-50-C5

C.O. Lines

24 Analog

PABX/KSU

Stations

Punch Down Terminal

Block with Split Center

(not included)

or

To 24 Monitored

Stations or Phones

AMPLIFIED REMOTE ACCESS DEVICE

VIKING

©

MODEL RAD-AMP

LINE IN

LINE OUT

OFF                    ON

Pins 25 & 50

Tip (V/S) and

Ring (S/V)

Pins 25 & 50 not used

on Slave modules

Note:  

Connect  

OUTPUT 

ports on slave modules to the 

INPUT 

ports of the superced-

ing 

SO-24A

’s, continuing from 

module to module to the 
Master module using the 
supplied modular cords.

Slave Module

IMPORTANT: 

 Each slave module MUST be 

programmed with its own unique set of dial up codes.

B.  Multi-Module Wiring

Summary of Contents for SO-24A

Page 1: ...a dedicated pair of wires be tween the handset and the SO 24A Monitor stations from an unused phone system line input or to a dedicated single line phone Add remote observing with a RAD AMP Re mote Ac...

Page 2: ...SO 24A W BL BL W W O O W W G G W W BN BN W W S S W R BL BL R R O O R R G G R R BN BN R R S S R BK BL BL BK BK O O BK BK GN GN BK BK BN BN BK BK S S BK Y BL BL Y Y O O Y Y G G Y Y BN BN Y Y S S Y V BL...

Page 3: ...X KSU Trunk Port Observing Phone 13 8V AC Adapter included RJ21X Male Jack not included Add up to 8 more SO 24A modules for a total of 240 stations Master Module ON OFF 1 ON OFF 1 DIP Switch 1 must be...

Page 4: ...ON or the only module in a single module system Slave Module s Any module s in addition to the Master module used to increase capacity DIP switch 1 OFF Installation A SO 24A system consists of at lea...

Page 5: ...in section B Enter digits 4 00 Important All SO 24A s in a system MUST be programmed with the same number of dial up code digits The SO 24A is factory set with the dial up codes for locations 1 24 fa...

Page 6: ...Set DIP switch 3 to ON see Programming section A and all monitored conversations will be recorded If a multi module system Master and Slaves is installed set DIP switch 3 on all modules to ON E Automa...

Page 7: ...66M150 Suttle SE 66M1 50 C5 C O Lines RJ21X Male Jack not included or 24 Analog PABX KSU Stations Supervisor 1 Module Bridge Clip the First 24 Pairs Only Punch Down Terminal Block with Split Center n...

Page 8: ...OR RELATED TO THE SALE OR USE OF THE PROD UCT SOLD HEREUNDER EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY WHETHER IN AN ACTION BASED ON CONTRACT TORT INCLUDING NEGLIGENCE OR STRICT LIABILITY OR ANY OT...

Reviews: