General Information

Water Supply Requirements

Use only 1/4” (6 mm) copper tubing for
water line. Do Not install copper tubing in
area where temperatures drop below
35˚ F (1.7˚ C). Before attaching copper
tubing to the unit, flush at least 2 quarts
(1.9 L) of water through the copper tubing
and into a bucket to remove any particles
in the water line.

• Viking Range Corporation is not

responsible for property damage due to
improper installation or water
connection.

• Connect 1/4” (6 mm) flexible copper tubing

to household plumbing in compliance with
local codes and ordinances.

• Length of copper tubing must reach from

water supply connection to the unit
connection with an additional length to
facilitate moving the unit out of enclosure
for cleaning or service. Tubing should be
soft instead of rigid and ends should be
free of burrs.

• Copper tubing route must be above 35˚ F

(1.7˚ C) to prevent water line from freezing.

• Do not use plastic water lines from the

household plumbing to the water inlet
valve connection on the refrigeration
unit.

• Do not use the self-piercing feature of a

saddle valve.

The hole made by the

piercing lance is too small for the water
flow rate required by the ice maker.

• If saddle valve is not used, place a

separate shut-off valve in an easily
accessible location between water supply
and the unit. Do not locate shut-off valve
behind the unit.

• The installation of Viking units with a

reverse osmosis system is acceptable

as long as the water pressure remains
within the allowable PSI as stated below.

It is important to note that with many
reverse osmosis systems, the pressure
starts off high, but then it decreases as the
water level of the reverse osmosis storage
area drops. This must be considered when
checking the water pressure coming into
the unit.

• Connect a vertical or horizontal 1/2” (1.2 cm)

to 1-1/4” (3.2 cm) COLD water line near
water area.

• Run water line through the floor, back, or

side wall. Tubing should lay flat on floor
underneath the unit. Clamp tubing to wall
or floor.

• Water pressure must be greater than 20 psi

and less than 120 psi on non-dispensers
and greater than 35 psi and less than 120
psi on dispensers.

35

Area Requirements

Verify the following:
• Unit can fit into residence and can be

moved around corners and through
doorways.

• Floors can support unit’s weight plus food

weight (approximately 1200 pounds [540 kg]
total).

• Rear wall is solid and is able to support

two horizontally mounted 2X4s (included)
bolted to two wall studs. The 2X4
board bolt heads must be flush with 2X4
to prevent obstruction.

• Remove anything attached to rear or side

walls that can obstruct unit installation.

• Cutout dimensions are accurate.

• Electrical outlet is in correct location.

• Water line is in correct location.

• Do not install a refrigeration unit near a

heat source, nor in a location where the
surrounding temperature will fall below
60º F (16º C).

Electrical Requirements

It is the customer’s responsibility to:
• Contact a qualified electrical installer.
• Assure that the electrical installation is

adequate and in conformance with the
National Electrical Code, ANSI/NFPA 70-
latest edition or Canadian Electrical Code
C22.1-1998 and C22.2 No. 0-M91 (or
latest edition), and all local codes and
ordinances. A 115 volt, 60-Hz, 15 amp,
fused, electrical supply is required. It is
required that a separate circuit serving only

this appliance be provided. This appliance
is equipped with a power supply cord
having a 3-prong grounding plug. To
minimize possible shock hazard, the cord
must be plugged into a mating 3-prong,
grounding-type wall receptacle.

Do not use an extension cord.

If codes permit a separate grounding wire to
be used, it is recommended that a qualified
electrician determine that the grounding
path is adequate.

DO NOT

ground to a gas pipe. Check with

a qualified electrician if you are not sure the
appliance is properly grounded.

DO NOT

have a fuse in the neutral or grounding
circuit.

Anti-Tip Requirements

The anti-tip boards should be fastened
into position prior to moving the unit into
the opening.

NOTE: Additional mounting boards may
be required if the unit does not touch
the back wall of the enclosure. To
prevent unit from tipping forward, it
must be secured in place with a solid
soffit or wood block.

34

General Information

C A U T I O N

Be sure to have a replacement cartridge available
when filter change is required.
•If water filtration system has been allowed to
freeze, replace filter cartridge.
•If system has not been used in several months, and
water has an unpleasant taste or odor, flush system
by dispensing 2-3 glasses of water. If unpleasant
taste or odor persists, change filter cartridge.

W A R N I N G

To avoid serious illness or death, do not use unit
where water is microbiologically unsafe or of
unknown quality without adequate disinfection
before or after the system. Systems certified for cyst
reduction may be used on disinfected water that
may contain filterable cysts. The contaminants or
other substances removed or reduced by this water
treatment system are not necessarily in you water.

Summary of Contents for Side-By-Side & Bottom-Mount Refrigerator/Freezer

Page 1: ... Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20414C 091207J Viking Installation Guide Side By Side Bottom Mount Refrigerator Freezer UL C UL ...

Page 2: ...fessional Integrated Side by Side Dimensions Specifications Professional 42 48 ________________________________ 4 Dimensions Specifications Professional Integrated 42 48 _______________________6 Cutout Dimensions 42 __________________________________________________________ 8 Anti Tip Dimensions 42 _________________________________________________________ 9 Cutout Dimensions 48 ___________________...

Page 3: ...inimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 425 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 243 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 652 lbs 293 4 kg 676 lbs 304 2 kg 48 Professional Side By Side Description VCSB483 VCSB483D Overall width 48 121 9 cm...

Page 4: ...tubing inlet waterline requirements minimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 411 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 244 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 625 lbs 293 4 kg 676 lbs 304 2 kg 48 Professional Integrated Side By Side Descri...

Page 5: ...f anti tip board 35 88 9 cm 3 1 2 8 9 cm 3 7 6 cm 35 88 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Professional Side By Side 9 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 41 1 2 105 4 cm min to 41 3 4 106 0 cm min 42 106 7 cm Professional Integrated models only 24 61 0 cm Electric Outlet Location Water Line En...

Page 6: ...d 41 104 1 cm 3 1 2 8 9 cm 3 7 6 cm 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Professional Side By Side 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 47 1 2 120 7 cm min to 47 3 4 121 2 cm max 48 121 9 cm Professional Integrated models only 24 61 0 cm Electric Outlet Location Water Line Entry Area 6...

Page 7: ...Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 9 amps Inlet water 1 4 copper tubing inlet waterline minimum 20 psi requirements maximum 120 psi Overall interior dimensions Refrigerator 15 2 cu ft 431 Liters Freezer 5 1 cu ft 145 Liters Total capacity 20 3 cu ft 576 Liters Approximate shipping weight 565 lbs 254 3 kg 36 Professional Integr...

Page 8: ...oard 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 5 3 8 cm Anti Tip Dimensions Professional Bottom Mount 15 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 35 1 2 90 2 cm min to 35 3 4 90 8 cm max 36 91 5 cm Professional Integrated model only 24 61 0 cm Electric Outlet Location Water Line Entry Are...

Page 9: ... cm Space if 24 standard cabinet depth is used Door 24 61 0 cm Standard Cabinet Depth Wall 3 4 1 9 cm Full End Panel 2 1 2 6 4 cm Offset Partial Overlay Cabinet Door Cabinet Information Professional 16 Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the ro...

Page 10: ... 4 62 9 cm Wall 3 4 1 9 cm Full End Panel 3 4 1 9 cm If standard 25 63 5 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm If standard 25 63 5 cm standard cabinet depth is used Flush 25 63 5 cm Cabinet Depth Cabinet Door Cabinet Information Professional Integrated 18 Professional Integrated models fit flush in standard 24 61 0 cm deep cabinet opening...

Page 11: ... Requirements minimum 20 psi maximum 120 psi minimum 35 psi maximum 120 psi Overall interior dimensions Refrigerator 15 0 cu ft 425 liters 15 0 cu ft 425 liters Freezer 9 0 cu ft 255 liters 8 6 cu ft 243 liters Total capacity 24 0 cu ft 680 liters 23 6 cu ft 668 liters Approximate shipping weight 642 lbs 289 kg 665 lbs 299 3 kg 48 Designer Side By Side Description DDSB483 DDSB483D Overall width 48...

Page 12: ...anti tip board 35 88 9 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Side By Side 23 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 42 106 7 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 42 106 7 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 4 27...

Page 13: ...ti tip board 41 104 1 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Side By Side 25 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 48 121 9 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 47 1 2 120 7 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 4...

Page 14: ...om rear To front edge of side trim 23 3 8 59 4 cm To front of top grille 24 61 0 cm To front of handle 26 66 0 cm Cutout width 36 91 5 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 9 amps Inlet water 1 4 copper tub...

Page 15: ...om of anti tip board 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions Designer Bottom Mount 29 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm min anti tip board opening height 36 91 5 cm 24 61 0 cm Electric Outlet Location Water Line Entry Area 36 91 5 cm 6 3 4 17 1 cm 7 5 8 19 4 cm 3 7 6 cm 5 8 1 6 cm 5 8 1 6 cm 10 1 2 26 7 cm 5 8 1 6 cm 10 3 ...

Page 16: ...1 0 cm Standard Cabinet Depth 24 3 4 62 9 cm Wall 3 4 1 9 cm Full End Panel 3 4 1 9 cm If standard 25 63 5 cm standard cabinet depth is used Flush Cabinet Door Door Wall 3 4 1 9 cm Full End Panel 1 2 5 cm If standard 25 63 5 cm standard cabinet depth is used Flush 25 63 5 cm Cabinet Depth Cabinet Door Cabinet Information Designer 30 Designer models fit flush in standard 24 61 0 cm deep cabinet ope...

Page 17: ...Integrated 33 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 61 0 cm 6 15 2 cm Optional kickplate Notch dimensions determined by cabinets 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 6 15 2 cm 22 1 4 61 0 cm Custom Side Panel Dimensions Professional 32 Depending on how high leveling feet are raised an...

Page 18: ...ounted 2X4s included bolted to two wall studs The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction Remove anything attached to rear or side walls that can obstruct unit installation Cutout dimensions are accurate Electrical outlet is in correct location Water line is in correct location Do not install a refrigeration unit near a heat source nor in a location where the surrounding...

Page 19: ...R HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or more people to move and install appliance Failure to do so can result in death or serious injury Unpacking Unit 1 Remove top and bottom strap 2 Remove top cap 3 Cut carton rear approximately 1 4 0 6 cm to 1 2 5 ...

Page 20: ...OTE DO NOT use plastic water lines 12 13 Flush water line by running two quarts of water into a bucket Turn water off Connect supply tube to water valve using a 1 2 wrench NOTE DO NOT overtighten 38 Remove four side screws and remove unit top Loosen the four hinge screws Adjust door Retighten four hinge screws Replace unit top Replace four side screws Attach one 2x4 to wall stud refer to dimension...

Page 21: ...or 120 position 40 Turn on water supply and check for leaks Lift unit off rollers to desired height and level unit using a 5 16 head wrench NOTE DO NOT use an electric device Overtightening can cause damage Attach positive secure self tapping bolts to 2x4 using a 22 extension Verify that drain pan is installed and aligned Align holes on both ends of louvered panels and insert screws Using a Philli...

Page 22: ...ation instructions parts and service availability and standard warranty are included with the product when shipped This drinking water system must be maintained according to manufacturer s instruction including replacement of filter cartridges Standard No 42 Aesthetic Effects Parameter USEPA Influent Influent Effluent Reduction Min Req McL Average Challenge Average Maximum Average Minimum Reductio...

Page 23: ...Install anti tip device s and verify unit is secure h Position unit in cutout level at desired height and secure unit h Plug in unit and verify operation h Connect water supply if applicable Verify icemaker fill tube is properly inserted Verify icemaker bail arm is down Verify dispenser operation if applicable h Align square door s h Verify drain pan is properly installed and no leaks on water con...

Page 24: ...ions Only authorized replacement parts may be used in performing service on the appliance Do not repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Record the following information indicated below You will need it if service is ever required The serial number and model number for your appliance ...

Reviews: