background image

7

Dimensions

6

Specifications

Note: 

Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and not certified by

CSA. Clearances to non-combustible materials must be approved by the authority having jurisdiction.
Minimum clearances from adjacent combustible construction:
  Below cooking surface (36” [91.4 cm] and below)

• Sides - 0”
•  Top grate support - 36” (91.4 cm)

Above cooking surface (above 36” [91.4 cm])

•  Sides - 6” (15.2 cm)
•  Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” 

(45.7 cm) above cooking surface

•  Wall cabinets directly above product must be a minimum of 42” (106.7 cm) above cooking surface
• Rear - 0” with 6  ” backguard or high shelf; 0” with island trim and non-combustible rear wall;
• 6” (15.2 cm) with island trim and combustible rear wall

Gas 30” W. Range

Description

RVGR

Overall width

29-7/8” (75.9 cm)

Overall height

To top of side trim - 35-7/8” (91.1 cm) min. 37” (94.0 cm) max.

Legs adjust - 1-1/8” (2.9 cm)

Overall depth
from rear

To front of side panel - 25” (63.5 cm) 

To front of door - 25-3/4” (65.4 cm)

To front of control panel - 27-1/8” (68.9 cm)

To end of knobs - 29” (73.7 cm)

Additions to Overall
Height

To top of island trim - add 0” (0.0 cm)

To top of backguard - add 6” (15.2 cm)

To top of high shelf - add 18-3/16” (46.2 cm)

Gas Requirements

Shipped standard for Natural gas, field convert with LP conversion kit included with each unit;

accepts standard residential 1/2” (1.3 cm) ID gas service line

Gas Manifold Pressure

Natural 5.0” W.C.P./ Liquid Propane L/P 10.0” W.C.P.

Electrical

Requirements

120VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 

3-prong plug attached to unit

Max Amp Usage

0.74 amps

Surface Burner Rating 
Natural/LP

Left front
Left rear
Center
Right rear
Right front

18,000 BTU Nat/15,800 BTU LP/Propane (5.3 kW Nat/4.8 kW LP/Propane)

8,000 BTU Nat/7,200 BTU LP/Propane (2.3 kW Nat/1.9 kW LP/Propane)
9,000 BTU Nat/8,300 BTU LP/Propane (2.7 kW Nat/2.4 kW LP/Propane)

12,000 BTU Nat/10,800 BTU LP/Propane (3.5 kW Nat/3.1 kW LP/Propane)
18,000 BTU Nat/15,800 BTU LP/Propane (5.0 kW Nat/4.5 kW LP/Propane)

Oven Interior Width

23” (58.4 cm)

Oven Interior Height

16-1/8” (40.9 cm)

Oven Interior Depth

Overall - 18-3/4” (47.6 cm)

AHAM - 15-3/8” (39.2 cm)

Oven Volume
Overall
AHAM

4.0 cu. ft.
3.3 cu. ft.

Approximate 
shipping weight 

410 lbs. 

(184.5 kg)

29-7/8”

(75.9 cm)

35-7/8”

(91.1 cm) min.

to

37”

(94

.0 cm) max.

RVGR

35-7/8”

(91.1 cm) min.

to

37”

(94 cm) max.

25-3/4”

 

(65.4 cm)

45”

 

(114.3 cm)

19-1/4”

(48.9 cm)

24”

 

(61.0 cm)

25”

 

(63.5 cm)

29”

 

(73.7 cm)

6”

(15.2 cm)

25”

 

(63.5 cm)

27-1/8”

 

(68.9 cm)

Note: 

Units shown with standard 6” backguard.

Summary of Contents for RVGR330

Page 1: ...t Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Website at vikingrange com F21185 EN 053113 Freestanding 30 Gas Self Clean Sealed...

Page 2: ...ich COULD result in minor personal injury or property damage All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions a...

Page 3: ...hich can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fu...

Page 4: ...im add 0 0 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 18 3 16 46 2 cm Gas Requirements Shipped standard for Natural gas field convert with LP conversion kit included with each uni...

Page 5: ...result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions provide for safe and ef...

Page 6: ...nal regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked with a mano...

Page 7: ...may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed a...

Page 8: ...ing hardware 3 Screw legs into couplings on all four corners Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit with met...

Page 9: ...ays check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company Leveling Adjustments Alignments cont Connecting Gas Electric WARNING TIPPING HAZARD To...

Page 10: ...m screws Door Replacement and Adjustment 1 2 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm 3 Burner heads and burner caps are packed in the cardboard top pack with the grates Align burner head on burner base Pl...

Page 11: ...allation instructions should remain with the unit for future reference Service Registration Performance Checklist A qualified installer should carry out the following checks Check top burner ignition...

Page 12: ...______________________________________________________________________________________________________ Notes ___________________________________________________________________________________________...

Reviews: