background image

19

18

1

2

Measure the four corners in cutout area 

to verify if flooring is level. 

For uneven or sloped floors, level unit with metal shims

only, as the adjustment required may exceed

the thread available in the leg.

Move unit into opening.

Leveling/Adjustments/Alignment

Electrical Connection (4-wire)

(cont.)

Check that unit is level side to 

side and front to back. Side trim of the high corner

must be 3/8” (0.95 cm) above countertop.

If leveling is required, move unit out of opening.

Lift unit and prop on wood blocks.

4

Feed supply cord up through hole in bottom 

of range back.

1

2

5

1

2

6

Attach ground lead (green) 

with ground screw that was removed.

Attach line #1 (red) and line #2 (black) 

leads to outside terminal. Attach neutral wire (white) to

center terminal on terminal block.

1

3

7

1

2

8

Push supply cord toward terminal

block to relieve strain, reattach supply cord strain

relief bracket over supply cord.

Reattach access door.

3

3/8”

3/

8”

 

(0.95 cm)

(0.

95

 cm

)

3/8”

 

(0.95 cm)

4

5

6

1

2

1

1

1

Eyelet Connection

Bare Wire Connection

To make a bare wire connection, use holes on the left

side of the terminal block. To connect eyelet style

wires, use holes on right side of terminal.

Summary of Contents for RVDR330

Page 1: ...treet Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Website at vikingrange com F21189 EN 053113 Freestanding 30 Dual Fuel Self Clean Seal...

Page 2: ...tant Safety Instructions_____________________________________________________3 Dimensions __________________________________________________________________________________6 Specifications____________...

Page 3: ...h defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained in accordance to the instructi...

Page 4: ...ements Shipped standard for Natural gas field convert with LP conversion kit included with each unit Accepts standard residential 1 2 1 3 cm ID gas service line Gas Manifold Pressure Natural 5 0 W C P...

Page 5: ...This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions pro...

Page 6: ...with this manual before work begins Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation si...

Page 7: ...ing used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it...

Page 8: ...grounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING ELECTRICAL S...

Page 9: ...wire power supply cord kit rated for 40 amps 125 250 volts with closed loop terminals and marked for use with ranges Where local codes do not permit grounding through neutral use a 4 wire power supply...

Page 10: ...t unit and prop on wood blocks 4 Feed supply cord up through hole in bottom of range back 1 2 5 1 2 6 Attach ground lead green with ground screw that was removed Attach line 1 red and line 2 black lea...

Page 11: ...ICE MUST BE RE ENGAGED WARNING TIPPING HAZARD To reduce the risk of the appliance tipping it must be secured by a properly installed anti tip bracket s To make sure the bracket has been installed prop...

Page 12: ...ts section for proper installation information Connect gas and electrical Before placing appliance in operation always check for gas leaks This must be performed by your dealer a qualified licensed pl...

Page 13: ...le to unlock door Final Preparation All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abr...

Page 14: ...service is ever required Model number ____________________________________________________________________________________ Serial number ______________________________________________________________...

Reviews: