Diagnostics
Upper/Lower Diagnostics (cont.)
Cycle Selector
–
To test the selector functions, the value is a four-digit value. The first digit is the cycle ID, from
0 to 9. The remaining three digits are the raw AD value, divided by two. Rotate “SET KNOB” and compare
values shown below
.
Note:
Start test with the selector in the OFF position.
From OFF, rotate the “SET KNOB” switch either direction
and compare display readout to charts shown here. Readings
should be – 10%.
Note:
It takes several seconds for all 4 digits to come up
in the display. Turn the knob and then wait for 10 seconds to
let the display settle out.
Note:
To test the UPPER selector, you must be in the UPPER
test mode. The same is true for the LOWER selector.
S
etpoint
When SEtP is in display, press “MIN/SEC TIMER”. With the thermostat in the OFF position, OF should be in the
display. Rotating the temperature dial to any temperature should register in the display. This will test the
potentiometer values of the thermostat.
AD
–Raw setpoint AD (Analog to Digital) value.
SKIP THIS TEST
Upper Oven
ID
bake
1
485
Convection Bake
2
418
Tru Convection
3
351
Convection Roast
4
292
Convection Broil
5
234
Hi broil
6
176
Med broil
7
126
Low Broil
8
073
Self-Clean
9
019
Lower Oven
ID
bake
1
480
Convection Bake
2
420
Tru Convection
3
354
Convection Roast
4
299
Convection Broil
5
244
Hi broil
6
186
Med broil
7
132
Low Broil
8
072
Self-Clean
9
016
Press
MIN/SEC
TIMER
Press
MIN/SEC
TIMER