![Viking RDGSU2005BSB Service Manual Download Page 15](http://html1.mh-extra.com/html/viking/rdgsu2005bsb/rdgsu2005bsb_service-manual_1023874015.webp)
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Shut-off gas valve supplying gas to cooktop prior to removal and
disassembly.
WARNING
!
Disassembly
©2012 Viking Preferred Service
15
Gas valve removal
DANGER
!
Failure to fully engage the gas shut-off prior to the following procedures could result in injury, property
damage and possibly death.
1. Disconnect Power from cooktop.
2. Turn gas supply off going to cooktop, in
future steps you will be removing gas lines,
it is imperative that gas supply is turned all
the way off to prevent gas leaking out.
3. Remove Stainless steel top, see Page 9 for
procedure.
4. Remove Iris spark module, see Page 14.
5. Disconnect output gas line connection, see
photo below.
Disconnect line and pull away from
valve being careful not to damage line
or valve.
6. When gas line has been removed, the
next step is to remove the bolt underneath
the manifold that secures the valve to the
manifold.
Remove bolt, making sure
that rubber seal between bolt
head and manifold is retained
for re-installation
7. At this time pull gas valve straight up and
out of manifold, being careful to retain
the upper seal that goes between the gas
valve body and manifold, if valve is being
replaced a new seal will be included with
the new valve..
Upper seal
between
valve and
manifold
Lower seal
between
bolt and
manifold