To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Shut-off gas valve supplying gas to cooktop prior to removal and
disassembly.
WARNING
!
Disassembly
12
©2012 Viking Preferred Service
6. Disconnect igniter wires from both burners, you can now remove the burners still mounted to
the support bracket.
7. Turn sub-assembly upside down to remove the two bolts holding the burner base to the
support bracket.
Threaded bolts go through
support bracket into the
burner base mounting holes,
indicated by arrows.
8.
If you are replacing the burner base you will have to transfer the orfice spud, igniter and clip
to the new base, see appropriate sections to accomplish their removal.