background image

12

G.  Viking IP Phone Relays

For Viking IP phone applications
requiring an extra level of security,
the 

RC-4A

can function as a remote

relay, with the 

RC-4A

securely

mounted inside the building.  At the
bottom of the Settings page, click
on VoIP Relay.

The VoIP Relays page provides a real-time display of the Viking IP series phones currently available for connection
to the 

RC-4A

.  For each phone, the device name, MAC address and network IP address are shown.  To enable

a phone to connect to the 

RC-4A

, click on its checkbox.  The Security Code box, which was greyed out, is now

white.  Enter the phone’s security code. Repeat this procedure for any other phones that are to be connected  to
the 

RC-4A

.  When you click on Apply, the 

RC-4A

attempts to connect to the phone or phones that have been

enabled.  This process typically takes 5 to 10 seconds but may take up to a minute.  When the connection has
been made, the status indicator changes to Connected.  Up to eight phones can be connected to one 

RC-4A

.

If a Viking IP phone is on a different subnet than the 

RC-4A

, it can be set up to control the 

RC-4A

using the

Manual Entries at the bottom of the page.  Click on Add Manual Entry, check the box, enter the phone’s IP address
and security code and click on Apply.  Additional manual entries are possible as long as the total of connected
phones does not exceed eight.

In operation, the phones control the 

RC-4A

remotely.  For example, if a visitor is to be let in, the user inside the

building dials a door strike command and an encrypted command string is sent across the network to the 

RC-4A

,

telling it which relay to close and how long to keep it closed.  For more information, see the product manual for
the Viking IP phone being used.

Note: 

The connection status only indicates that the phone and 

RC-4A

are communicating over the network. It

does not indicate functionality. The phones will connect, but will not be able to activate the relay if the security
code is wrong. The phone must be configured in the Viking VoIP Programming software and operation should be
verified with a phone call.

Summary of Contents for RC-4A

Page 1: ...1 to 99 seconds can be activated Terminal strip connections for all four sensor inputs Notification by email or text message of sensor input state change Can be used as a secure remote relay for Viki...

Page 2: ...ecure but may not work with some browsers or smartphones Client A computer or device that makes use of a server As an example the client might request a particular file from the server DHCP Dynamic Ho...

Page 3: ...he MAC address printed on the unit s network jack or by looking at the device name Important If more than one RC 4A will be installed on the network each unit must be assigned its own unique device na...

Page 4: ...changed It s when the user is logged in as an Administrator that Dipswitch 2 makes a difference If Dipswitch 2 is OFF programming is permitted If Dipswitch 2 is ON programming is blocked even when th...

Page 5: ...dialog appears For User Name enter admin and for Password enter viking The main page appears Note that all four remote sensor inputs are shown Open and the relays are all Off The relays may be toggled...

Page 6: ...the On position When their times are up they will return to the Off position The RC 4A also provides a status indication for the four inputs on the input terminal block In the picture below Input 1 an...

Page 7: ...button is clicked Note that these times can be overridden by entering another value in the timed closures box on the main page and clicking Start The next time the main page is activated however the...

Page 8: ...o change Click on OK On the dialog that appears next check the box for Prevent this page from creating additional dialogs It should be noted that this method of operation is not secure and should only...

Page 9: ...ail notification of input events The RC 4A can be programmed to send an email if one of the inputs closes and also if it opens As described in Programming A Settings 2 Input Status Phrasing the input...

Page 10: ...r sms alltelwireless com AT T phonenumber txt att net Boost mobile phonenumber sms myboostmobile com Cricket Wireless phonenumber mms cricketwireless net MetroPCS phonenumber mymetropcs com Project Fi...

Page 11: ...timed closures are not permitted Action Programming Grid The lower part of the Remote page is a programming grid with inputs shown on the lines and relays in the columns Clicking on a button selects w...

Page 12: ...cted Up to eight phones can be connected to one RC 4A If a Viking IP phone is on a different subnet than the RC 4A it can be set up to control the RC 4A using the Manual Entries at the bottom of the p...

Page 13: ...tom of the settings page click on Create Link Select the relay and the action to perform and click on Create Link The link will appear just below the button and can be pasted into the address bar to p...

Page 14: ...Viking distributor If at any time during the warranty period the product is deemed defective or malfunctions return the product to Viking Electronics Inc 1531 Industrial Street Hudson WI 54016 Custome...

Reviews: