Viking RAD-AMP User Manual Download Page 4

D. Programming Examples

Programming the RAD-AMP to...

1.

...be in the Line Extender mode

2.

...set the PABX outside line number to 9

3.

...set “Priority 2” access code to 345678

4.

...disable “Priority 1” access code

5.

...set the call timer to  20 minutes

Enter Digits

1

9 #44
345678 #46
#45
40 #48

1. Line Extender Mode

Telecommuting Extender Quick Programming Features

Set the 

RAD-AMP

to Line Extender mode (see section 

A

) .......................................

Set the 

RAD-AMP

to Call Diverter mode (see section 

B

)  ........................................

Set the 

RAD-AMP

to Telecommuting Extender mode  .............................................

Security code (6 digits 0-9) (factory set to 845464)  ..................................................
Priority 1 access code (enter 6 digits, no digits disables) (factory disabled)  .............
“Priority 2” access code (enter 6 digits, no digits disables) (factory disabled)  ..........
PABX outside line number (enter 1 digit, no digit disables) (factory set to 9)  ............
First remote phone number (1-32 digits each)  .........................................................
Second remote phone number (1-32 digits each)  ....................................................
Third remote phone number (1-32 digits each)  ........................................................
Fourth remote phone number (1-32 digits each)  ......................................................
Fifth remote phone number (1-32 digits each)  .........................................................
Sixth remote phone number (1-32 digits each)  ........................................................
Seventh remote phone number (1-32 digits each)  ...................................................
Eighth remote phone number (1-32 digits each)  ......................................................
Ninth remote phone number (1-32 digits each)  ........................................................
To enter a “

” in the remote phone number  ..............................................................

To enter a “#” in the remote phone number  ..............................................................
Supervised call forwarding (factory enabled)  ...........................................................
Un-supervised call forwarding  .................................................................................
To enter a 1 second pause in the remote phone number  .........................................
Maximum call timer (enter 2 digits*, no digits disables - factory disabled) .................
Ring delay (1-9) (factory set to 1)  .............................................................................
Alert tones On (call progress beeps) (factory enabled)  ............................................
Alert tones Off  ..........................................................................................................
Enable dial tone detection (for installations without CPC or busy signal)  .................
Disable dial tone detection (factory setting)  .............................................................
Exit programming and disconnect  ...........................................................................
Set all programming features to factory settings  ......................................................

* Note: 

Call timer digits specified as follows: 00 = 15 seconds, 01-99 = .5 - 49.5 minutes in .5 minute increments.

1

2

3

6 digits
6 digits
6 digits
1 digit
1-32 digits
1-32 digits
1-32 digits
1-32 digits
1-32 digits
1-32 digits
1-32 digits
1-32 digits
1-32 digits

✱ ✱

#

4

7

8

2 digits
1 digit

9

0

5

6

# 7
###

#47
#45
#46
#44
#01
#02
#03
#04
#05
#06
#07
#08
#09

# 48
# 49

Enter Digits

then
then
then
then
then
then
then
then
then
then
then
then
then

then
then

- then - Enter Memory Location

Programming the RAD-AMP to...

1.

...be in the Call Diverter mode

2.

...set the call diverter number to 1-715-386-8861 (up to 32 digits)

3.

...dial 9 (for outside line), pause 1 second, then dial 386-8861

Enter Digits

2

17153868861 #00

8 3868861 #00

2. Call Diverter Mode

Programming the RAD-AMP to...

1.

...be in the Telecommuting Extender mode

2.

...set the first remote number to 1-715-386-8861

3.

...set the PABX outside line number to 9

4.

...set “Priority 1” access code to 123456

5.

...clear the “Priority 2” access code

Enter Digits

3

17153868861 #01
9 #44
123456 #45
#46

3. Telecommuting Extender Mode

C. Telecommuting Extender Mode

(Remote Employee)

To access programming in the “Telecommuting Extender” mode, call into the 

LINE IN

port. After the 

RAD-AMP

answers, enter a 

followed by the security code, factory set to V-I-K-I-N-G (

845464

). The 

RAD-AMP

will beep twice indicating that programming has

been accessed.  It is recommended that the factory security code be changed.  While programming, if 20 seconds elapses between
Touch Tones, the 

RAD-AMP

will disconnect.  All valid Touch Tone programming sequences are acknowledged with a double beep.

A triple beep indicates that a mistake has been made.  

Note:

If a “Priority 2” access code is used, program the “PABX outside line

number” with the Touch Tone required to access a C.O. line from a PABX extension.

4

Summary of Contents for RAD-AMP

Page 1: ...loyees or locations As a line extender the RAD AMP provides authorized users remote access to PABX Centrex or Electronic Key system features As a call diverter the RAD AMP provides call forwarding from one location to another After detecting an inbound call the RAD AMP accesses a second phone line dials a preprogrammed Touch Tone number and then bridges the two lines As a Telecommuting extender th...

Page 2: ... areas or allowing remote employees to use company lines for toll calls Call Diverter The mode of operation in which the RAD AMP forwards a call to a pre programmed phone number Telecommuting Extender The mode of operation in which the RAD AMP forwards calls to one of nine pre programmed numbers as well as providing remote access to an analog PABX KSU station or C O line including all features ava...

Page 3: ...ation section D Maximum call timer enter 2 digits no digits disables factory disabled Ring delay 1 9 factory set to 1 Alert tones On call progress beeps factory enabled Alert tones Off Enable dial tone detection for installations without CPC or busy signal Disable dial tone detection factory setting Exit programming and disconnect Set all programming features to factory settings Note Call timer di...

Page 4: ...tory setting Exit programming and disconnect Set all programming features to factory settings Note Call timer digits specified as follows 00 15 seconds 01 99 5 49 5 minutes in 5 minute increments 1 2 3 6 digits 6 digits 6 digits 1 digit 1 32 digits 1 32 digits 1 32 digits 1 32 digits 1 32 digits 1 32 digits 1 32 digits 1 32 digits 1 32 digits 4 7 8 2 digits 1 digit 9 0 5 6 7 47 45 46 44 01 02 03 0...

Page 5: ...he RAD AMP allows an employee to work from a remote location by pro viding most PABX features to be utilized from their home or cell phone All programming features including mode of operation access codes security codes call timers alert tones and phone numbers are programmable from a standard Touch Tone phone see Programming The RAD AMP provides a remote night mode contact input which can be conn...

Page 6: ...hang up When a valid access code has been entered the RAD AMP will double beep and bridge the lines together providing access to the opposite line port Anybody that calls into the RAD AMP and successfully dials the Priority 1 access code has unlimited access to the extended line 3 Priority 2 limited Access This mode is specific to PABX applications When a Priority 2 access code has been programmed...

Page 7: ...e employee can Log In by programming one of the nine pre pro grammed phone numbers as the forwarding number see section 1 3 Remote PABX KSU Feature Use 2 Supervised and Unsupervised Forwarding b Unsupervised Forwarding The remote employee calls into the LINE IN port of the RAD AMP hears a single beep tone and dials 0 A logged out employee will appear as a busy PABX KSU station Unsupervised forward...

Page 8: ...t can also provide bridging to a second central office line With two levels of access and programmable toll restriction the RAD 1 provides the security required to help prevent phone sys tem and toll abuse The RAD 1 answers on the first ring and disconnects on CPC time out or by dial ing 7 The 600 ohm LINE OUT port provides loop closure for audio access to sys tem features or an external device Fo...

Reviews: