4

Features Overview

MAC Address Label: 

The MAC 

address is a unique 12 digit number 
used by routers to send network 
traffic to the correct IP address.

Side View 

Reset Switch: 

See page 9, section D and E.

Front View 

Front View 

PoE LAN Port 10/100, PoE Class 3 (<13 Watts): 

Connect  to  your  LAN  via  RJ45  plug  and  CAT5  or 
greater twisted pair wire.

Yellow Network Status LED: 

Lights steady to indicate 

power and data link. Blinks to indicate network activity.

Green Unit Status LED

40AE

Speaker
Out 

30AE

25AE

35AE

Drive up to (6) Analog Speakers

(Viking Models shown, not included, see DOD 497 and 498)

300AE

Volume Control

30AE

See 

MANAGING POWER LOSS

 section on page 2 of Product Manual.

Red Call/Status LED:

  Flashes 

during dialing, then lights steady 
when answered.

MAC:

18E80FXXXXXX

asdesaxtff

RED

BLACK

Summary of Contents for PSA-IP

Page 1: ...P Level Amplifier 6 Watt class D Connections 1 RJ45 10 100 Base T 4 Butt Connectors The PSA IP Speaker Adapter enables you to quickly convert any 8 Ohm 25V or 70V analog paging speaker into a SIP endpoint paging speaker After the quick conversion the speaker can then be used for standard one way SIP endpoint paging or multicast paging The compact chassis of the PSA IP can be mounted magnetically t...

Page 2: ... wire run lengths Note 2 Using half the recommended distance or half as many speakers per run will keep the volume lost limited to 3db Note 3 Doubling up the wires will allow double the length or reduce the amount of volume loss Note 4 Heavier gauge wire fewer speakers per run and shorter runs will all minimize volume loss 16 18 20 22 24 1 2 3 4 5 2 000 1 250 800 500 315 1 000 625 400 250 155 665 ...

Page 3: ...otocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer or device that fulfills requests from a client This could involve the server sending a particular file requested by the client Session Initiation Protocol SIP Is a signaling communications protocol wide...

Page 4: ...5 plug and CAT5 or greater twisted pair wire Yellow Network Status LED Lights steady to indicate power and data link Blinks to indicate network activity Green Unit Status LED 40AE Speaker Out 30AE 25AE 35AE Drive up to 6 Analog Speakers Viking Models shown not included see DOD 497 and 498 300AE Volume Control 30AE See MANAGING POWER LOSS section on page 2 of Product Manual Red Call Status LED Flas...

Page 5: ...eiling tile with speaker suspended ceiling or remove speaker from drywall and disconnect the cable connected to the transformer input wires Step 2 Cut the transformer output wires leaving excess wire for the speaker wire connections Strip wire ends back 3 8 inch Step 3 Magnetically attach the PSA IP to the back of the speaker magnet Alternatively the PSA IP can be attached to the 70V transformer m...

Page 6: ...cable keeps 1 Gbps network speed for other equipment on network Available LAN with PoE class 3 13 Watts Ethernet cable CAT5 minimum 1 MB minimum free hard drive space for installation 16MB of free physical RAM Download and install the programming software 1 Go to www vikingelectronics com and enter PSA IP in the search box 2 Click PSA IP in the search results 3 Scroll down the page to Downloads cl...

Page 7: ...show you each PSA IP speaker that is connected to that LAN Select the unit with the same MAC address shown on the label located next to the Ethernet connector on the PSA IP speaker Step 3 Click on the connect button A default PSA IP has no username or password programmed the security code is set to 845464 and when configured this way you are instantly connected to the PSA IP If the PSA IP has been...

Page 8: ...lecting an integer 1 to PSA 94 in ID for all packets Step 4 Set the Priority Code Point PCP value for all not SIP and RTP packets in the PCP for all packets input 0 is default priorities are from low to high 0 1 2 3 4 5 6 7 Set the PCP for SIP packets 3 is default Set the PCP for RTP packets 5 is default C Configuring PSA IP VLAN Settings ...

Page 9: ...elease the button Step 4 You can now enter programming by following the steps in section A Programming Features Index DESCRIPTION Section Page Connect Disconnect A 7 VLAN Settings C 8 Unit Name 1 10 SIP Server 2 10 Peer to Peer Settings 3 10 Outbound Proxy 4 10 Authentication ID 5 10 Register Fails Re Resolve or Alternate Server 6 10 Security Code factory set to 845464 7 11 Access Code 1 6 digits ...

Page 10: ...r unit name can be assigned to the PSA IP being programmed Programming Features Enter the IP address or URL of your SIP server or service provider in this field The SIP server IP address is limited to 74 characters Note If an alternate SIP server IP address is programmed the IP address for the SIP server and alternate SIP server will be limited to 31 characters Note If outbound proxy is not requir...

Page 11: ...ctory Setting Standard shown above 9 Pre Page Tone When enabled a short beep will be heard prior to SIP or Multicast paging audio The volume of the Pre Page Alert Tone will match the volume setting of the SIP or Multicast page Factory Setting Enabled 10 Multicast Page Type The Access Code is primarily used along with the Auto Answer Secure Inbound Call Mode to force inbound SIP page callers to dia...

Page 12: ...e SIP Page Priority Level can be set to Polycom or None See the following tables for the order of priorities with each setting As shown Polycom Group 25 multicast is the highest priority The priority options allow you to determine the priorities for Polycom Groups 1 through 24 multicast signals and SIP paging Factory Setting Polycom 11 SIP Page Priority over Multicast Page Paging Priorities SIP Pa...

Page 13: ...o limit to how many speakers can be in a given paging zone Each multicast group is defined by a multicast address and port number Each multicast group is assigned a priority allowing simultaneously arriving pages to be serviced based on importance Polycom Polycom IP phones send multicast audio to a specific IP address and port A total of 25 groups can be used with group 25 generally reserved for a...

Page 14: ...rmine how SIP calls are handled NOTE For timed Night Ringing the unit must be synced with a time server If the Night Ringing feature is enabled in the software you will be asked to use Viking Time Server when changes are applied The address will be entered by the software automatically 15 Time Zone Settings Daylight Savings Time When using the Night Ring Timed Operation the PSA IP must be synced w...

Page 15: ...2 strobe light etc Ring Flash Mode When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400 ms on off cadence while the ringing extension is called This mode is useful for activating a Viking LPL 1 Remote Visual Indicator etc The one or two digit code stored in the Ext Relay Command is the touch tone command that the person being called must enter on their phone in o...

Page 16: ... One option is to generate a loud ring sound through the speaker The PSA IP can also auto answer a SIP call to transmit a page or control the relay The secure options for auto answer require the callers to dial the access code in order to transmit a page or activate the optional RC 4A relays Factory Setting Auto Answer Disabled Inbound SIP calls are not allowed For more security use the Auto Answe...

Page 17: ...he PSA IP If the PSA IP has been programmed with a username and password a pop up window will ask for the username followed by the password If the unit s security code has been changed from default 845464 it will then prompt for the correct security code If the username and password are unknown they can only be erased by resetting all network parameters to default with the reset button see section...

Page 18: ...e Clear Speaker Settings button in programming will reset all of the Programming Features back to their factory default settings NOTE This command will not change or reset your IP settings 34 Clear Speaker Settings Clicking on the Clear IP Settings will reset all of the IP settings back to their factory default settings This also clears paging Group settings and Addresses NOTE This will not affect...

Page 19: ...ge Type to Polycom Standard Multicast Paging Factory Setting Up to 10 multicast paging groups can be programmed into each unit and each group is assigned a priority level allowing simultaneous arriving multicast pages to be handled based on importance Low priority groups are often used for low priority streams like background music and high priority groups are used for high priority streams such a...

Page 20: ...SIP call when the Inbound Call Mode is set to auto answer After the unit auto answers the call one beep will be heard if Pre Page Alert Tone is enabled If the Access Code has been disabled you can now enter the Operation Commands listed below If an Access Code has been programmed enter the Access Code digits Once the correct code has been entered two beeps will be heard and you can now enter the O...

Page 21: ... Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc 2 Gel Filled Butt Connectors included Doorstrike Magnetic Lock 120V AC Door near Speaker 4 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30VDC 250VAC max PSA IP PSA IP PSA IP PSA IP For applications requi...

Page 22: ...ht during paging For more info see DOD 503 40 IP IP Speaker for SIP Endpoint Paging SIP Multicast Paging Adapter PA IP 30AE and 35AE Ceiling Speakers White metal grill Flush mount in office ceilings Mounting hardware included Excellent frequency response The 35AE includes a volume control 25AE Paging Horn Adjustable base for easy mounting and directional adjustment Compact design for discreet moun...

Page 23: ... The PA 15 interfaces with virtually any telephone system to provide 15 Watts of paging power enough to drive fifteen 8 Ohm paging horns or speakers This small and light weight chassis design is possible by utilizing new amplifier technology that is 300 less inefficient than old designs competitors use High efficiency means much less heat disipation smaller size higher reliability and lower cost T...

Page 24: ...ND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH If trouble is experienced with the PSA IP Speaker for repair or warranty information please contact Viking Electronics Inc 1531 Industrial Street Hudson WI 54016 715 386 8666 WHEN PROGRAMMING EMERGENCY NUMBERS AND OR MAKING TEST CALLS TO EMERGENCY NUMBERS Remain on the line and briefl...