17
28. Mute Current / Next Alarm
With Alarm Tones Enabled a network failure alarm will be indicated by providing 3 beeps every 30 seconds. A network
failure indicates the unit is not registered to the SIP server or there is a communication failure with the gateway. The
three beeps can be muted by clicking on “Mute Current / Next Alarm”. The Status LED will continue to flash to assist
troubleshooting. The alarm beeps can also be permanently disabled, see 44. Permanent Alarm Mute.
Factory Setting:
Disabled
29. Permanent Alarm Mute
Alarm Tones are disabled by default. To enable alarm tones select “Alarm Tones Enabled”.
30. Programming Username and Password to Restrict Access to Programming
To increase security, a username and password can be programmed to limit access to the
PSA-IP
using Viking IP
Programming software. When no username and password are programmed and the security code is still set to default
(845464), the PC software will not require a username, password or security code when connecting to the
PSA-IP
. If
the
PSA-IP
has been programmed with a username and password, a pop up window will ask for the username followed
by the password. If the unit’s security code has been changed from default (845464), it will then prompt for the correct
security code.
If the username and password are unknown, they can only be erased by resetting all network parameters to default
with the reset button (see section E on page 9). If the username and password are known but you wish to erase them,
that can be accomplished by exporting the data from the
PSA-IP
(“Alarm / Firmware” tab of Viking IP Programming),
resetting all network parameters to default with the reset button (see section E on page 9) and then importing the data
back into the speaker.
27. Ring Cadence
The Ring Cadence can be programmed to one of four different cadences.
Factory Setting:
Normal Ring
Normal Ring
(single ring: 2 seconds ON, 4 seconds OFF)
Double Ring
(double ring: 1 second ON, 0.5 second OFF, 1 second ON, 3.5 seconds OFF)
Short-Short-Long
(triple ring: 0.5 second ON, 0.5 second OFF, 0.5 second ON, 0.5 second OFF, 1 second ON, 3 seconds OFF)
Short-Long-Short
(triple ring: 0.5 second ON, 0.5 second OFF, 1 second ON, 0.5 second OFF, 0.5 second ON, 3 seconds OFF)