TECHNICAL DATA

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058

Telephone: 269-945-9501  Technical Services: 877-384-5464  Fax: 269-818-1680  Email: [email protected]

Page 4 of 6

Form No. F_052014  Rev 14.1

Approval Chart 1 (UL)

Micromatic

®

 Standard Response Upright Sprinkler VK100

 

Maximum 175 PSI (12 bar) WWP

Sprinkler 

Base Part 

Number

1

SIN

Thread Size

Nominal K-Factor Overall Length

Listings and Approvals

(Refer also to UL Design Criteria.)

NPT

BSP

U.S.

metric

2

Inches

mm

cULus

4

VdS

LPCB

               

Standard Orifice

12986

VK100 1/2”

15 mm

5.6

80.6

2-1/4”

57

A1, B3, C4, D2, E5

--

--

--

12993

VK100

--

20 mm

5.6

80.6

2-1/4”

57

A1, B3, C4, D2, E5

--

--

--

Approved Temperature Ratings

A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 

200 °F (93 °C), 286 °F (141 °C), and 360 °F (182 

°C)

B - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 

and 200 °F (93 °C)

C - 286 °F (141 °C)
D - 500 °F (260 °C)

7

E - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 

°C), 286 °F (141 °C),  360 °F (182 °C), and 500 °F 

(260 °C)

7

Approved Finishes

1 - Brass, Chrome, White Polyester

5,6

, and Black Polyester

5,6

2 - Brass and Chrome
3 - Wax-Coated Brass and Wax Over Polyester

5

4 - High Temperature 200 °F (93 °C) Wax Coating (corrosion resistant); maximum ambient tem-

perature allowed at ceiling = 150 °F (65 °C)

5 - ENT

5

Footnotes

Base part number is shown. For complete part number, refer to Viking’s current price schedule.

Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 

This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals.

Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada.

5

 cULus Listed as corrosion resistant.

6

 Other colors are available on request with the same Listings and Approvals as the standard colors.

7

 Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 

300 °F (149 °C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 °F (149 °C), 

the response time of the Ultra-High temperature rated sprinkler may be severely retarded.

DESIGN CRITERIA - UL 

(Also refer to Approval Chart 1.)

cULus Listing Requirements:

 

The Viking Micromatic

®

 Standard Response Upright Sprinkler VK100 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with 

the latest edition of NFPA 13 for standard spray sprinklers.

• Designed for use in Light, Ordinary, and Extra Hazard occupancies. 

• 

The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.

IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page 

SR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor-

dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS 

or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, 

whenever applicable. 

Summary of Contents for Micromatic VK100

Page 1: ...bar wwp Factory tested hydrostatically to 500 psi 34 5 bar Thread size 1 2 NPT 15 mm BSP Nominal K Factor 5 6 U S 80 6 metric Glass bulb fluid temperature rated to 65 F 55 C Overall Length 2 3 8 60 mm cULus Listing FM Approval and NFPA 13 installs require a minimum of 7 psi 0 5 bar The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi 0 35 bar Metric K factor measurement shown is ...

Page 2: ...1 B Twelve head capacity Part No 01725A available since 1971 4 INSTALLATION Refer to appropriate NFPA Installation Standards 5 OPERATION During fire conditions the heat sensitive liquid in the glass bulb expands causing the glass to shatter releasing the pip cap and sealing spring assembly Water flowing through the sprinkler orifice strikes the sprinkler deflector forming a uniform spray pattern t...

Page 3: ...86 F 141 C Dk Brown Wax5 Footnotes 1 The sprinkler temperature rating is stamped on the deflector 2 Based on NFPA 13 Other limits may apply depending on fire loading sprinkler location and other requirements of the Authority Having Jurisdiction Refer to specific installation standards 3 Sprinklers of Ultra High temperature rating are intended for use inside ovens dryers or similar enclosures with ...

Page 4: ...r shown by 10 0 3 This table shows the listings and approvals available at the time of printing Check with the manufacturer for any additional approvals 4 Listed by Underwriters Laboratories Inc for use in the U S and Canada 5 cULus Listed as corrosion resistant 6 Other colors are available on request with the same Listings and Approvals as the standard colors 7 Sprinklers of Ultra High temperatur...

Page 5: ...is table shows the listings and approvals available at the time of printing Check with the manufacturer for any additional approvals 4 Other colors are available on request with the same Approvals as the standard colors 5 Sprinklers of Ultra High temperature rating are intended for use inside ovens dryers or similar enclosures with normal operating temperatures above 300 F 149 C Where the ambient ...

Page 6: ...No F_052014 Rev 14 1 Figure 2 Wrench 13577W B for Wax Coated Sprinklers Wax Coated Upright Sprinkler Step 1 Carefully slide the wrench sideways around the deflector ensuring engage ment with the sprinklger wrench flats Sprinkler wrench 13577W B must be used for installing wax coated sprinklers A 1 2 ratchet is required not available from Viking Step 2 Carefully press the wrench downward and ensure...

Reviews: