Viking K-1705-3 Technical Practice Download Page 6

B. Volume Adjustments

C. Auto-Answer Feature

(DIP Switch 7)

With DIP switch 

7

in the “

ON

” position (default), the 

K-1705-3

will automatically answer the line during the first incom-

ing ring.  This feature is useful for monitoring entrances.  In the “

OFF

” position, the 

K-1705-3

will not automatically

answer incoming calls.

Certain noisy locations (background traffic,
machinery or wind) may cause one way talk path
(only microphone audio is heard).  In this case,
the microphone volume may need to be
decreased as shown. 

D. Push Button Hang Up

(DIP Switch 8)

With DIP switch 

8

in the “

ON

” position (default), the 

“Call

” button alternately connects and disconnects calls.  In the

OFF

” position, the “

Call

” button is only used to connect and the 

K-1705-3

must rely on call progress (busy, return to

dial tone, silence time-out, or maximum call time) for an automatic disconnect.

With DIP switch 

4

in the “

OFF

” position (default), the VOX switching speed (delay time between talk and listen mode)

is set to fast (0.2 seconds).  In the “

ON

” position, it is set to slow (0.7 seconds).

E. VOX (Talk/Listen) Switching Speed

(DIP Switch 4)

The 

K-1705-3

will output 3 beeps and automatically hang-up after detecting any of the following: busy signal (standard

or fast/reorder), CPC (short break in line current when called party hangs up), return to dial tone, maximum call time
or silence time out.

F. Advanced Call Progress Detection

VIKING

Model:

K-1705-3

261102-1

Serial No:

REN: 1.0B

XXXXXXXX

Viking Electronics, Inc.    (715)  386-8861

1531 Industrial St., Hudson, WI  54016

P/N:

DEV:

Complies with FCC Part 15 and 68 Reg. No: AH3USA-32531-TE-E

RoHS

Microphone Volume

Speaker Volume

Off

Off

1. Microphone

To increase, decrease or turn off the speaker (for
monitoring purposes only), adjust the speaker
volume control as shown.

2. Speaker

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

When the push button is pressed, the 

K-1705-3

phone goes off-hook, much like a standard speaker phone.  The keypad

may then be used to dial any number.  In the event that the line is busy, the 

K-1705-3

will hang-up.  The 

K-1705-3

will also

automatically hang up on CPC, silence, busy signal, return to dial tone or time out. If programmed to auto-answer (DIP
switch 7 

ON

), the 

K-1705-3

will also answer any incoming call. 

The 

K-1705-3

color video camera operates completely independently of the 

K-1705-3

phone board. With power supplied

to the camera, it will continuously output a video signal.

6

Summary of Contents for K-1705-3

Page 1: ...ting hardware K 1705 3 EWP is designed to meet IP66 Ingress Protection Rating see DOD 859 for more information Available in 2 standard faceplate finishes 316 brushed stainless steel or oil rubbed bron...

Page 2: ...ompany For products approved after July 23 2001 the REN for this product is part of the product identifier that has the format US AAAEQ TXXXX The digits represented by are the REN without a decimal po...

Page 3: ...push again to disconnect Solid marine grade 316 stainless steel internally sealed per IP67 Call VIKING 1 2 ABC 3 DEF 4 GHI 5 JKL 6 MNO 7 PRS 8 TUV 9 WXY 0 OPER Color Video Camera Wide operating tempe...

Page 4: ...try System not included DOD 162 Note To increase surge protection loosen the PCB mount ing screw labeled as shown right and fasten a wire with spade terminal included from the mounting screw to Earth...

Page 5: ...sting the Camera The camera can be tilted and rotated to your desired position A portable service test monitor can be used to determine the correct viewing angle during installation Important To preve...

Page 6: ...1705 3 will output 3 beeps and automatically hang up after detecting any of the following busy signal standard or fast reorder CPC short break in line current when called party hangs up return to dia...

Page 7: ...rike Magnetic Lock Relay Contact Specifications 5A 30VDC 250VAC maximum or Normally Closed Relay Contact Normally Open Relay Contact Auxiliary Relay Trigger Input momentary contact closure from postal...

Page 8: ...K RED GRN WHT ENTRY 3 BLK RED GRN WHT ENTRY 4 C O LINE INPUT AUX LINE ENTRY PHONE 1 ENTRY PHONE 2 ENTRY PHONE 3 ENTRY PHONE 4 REX 1 REX 2 REX 3 REX 4 H L LOG BUS RS 232 PORT PROGRAM PHONE or 610m 2000...

Reviews: