43. REX Input

Operation

A.  Keypad 

When a Keypad button is pressed, the 

K-1205-IP

immediately dials the pre-programmed telephone number stored in

the corresponding Phone Number Database Index location (1-#). The Call Status LED momentarily flashes during
dialing. In the event the line is busy or there is a ring-no-answer, the unit can be programmed to call a second roll over
number.

When the call is answered, relay activation commands can be entered or the # key can be used to force the phone to
hang-up.

After communication is established, enter the 1 or 2 digit relay activation command (factory set to “

,,

” for Relay 1 and

,

2” for Relay 2) to momentarily activate the entry phone (door strike) relay. Two beeps    will be heard confirming that

the relay has been activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones

11

” or “

21

” to continuously activate relay 1 or relay 2 respectively. A double beep will indicate that the relay is latched

on. When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones “

10

” or “

20

” to deactivate

relay 1 or relay 2 respectively. A single beep will indicate the relay is latched off. The relays can be toggled by entering

1#

” and “

2#

” for relays 1 and 2.

The 

K-1205-IP

has one Request for Exit (REX) trigger input. The REX switch must have a momentary, normally open

contact. When the 

K-1205-IP

detects a contact closure on the REX trigger input it performs one of the following actions,

based on the Relay Mode settings for each relay (see section 22):

Relay 1 "Door Strike", relay 2 other:

Relay 1 will be activated for the programmed Relay 1 Activation Time.

Relay 1 other, relay 2 "Door Strike": 

Relay 2 will be activated for the programmed Relay 2 Activation Time.

Relay 1 "Door Strike", relay 2 "Door Strike":

If the Relay Activation Delay is disabled, Relay 2 will be activated for

the programmed Relay 2 Activation Time. If Relay Activation Delay is not disabled, Relay 2 will be activated for the
programmed Relay 2 Activation Time, then after the Relay Activation Delay time has passed, Relay 1 will be activated
for the programmed Relay 1 Activation Time. This is useful in two door vestibule applications where Relay 1 is used to
unlock the outside door, and Relay 2 is used to unlock the inside door.

Note: 

For security reasons this input is disabled when the relay is set to “External”.

Clicking on the “Clear Unit settings”  button in programming will reset all of the Programming Features back to their
factory default settings.  

Note: 

This    command will not change or reset your IP settings.

40. Clear Unit Settings

42. Diagnostics

Clicking on the “Clear IP Settings” will reset all of the IP settings back to their factory default settings. This also clears
paging Group settings and Addresses.  

Note: 

This will not effect any speaker or paging settings.

41. Clear IP Settings 

The Diagnostics section in the Viking IP Programming can be used to test the functionality of the two relays, read
current relay status, perform mic/spkr diagnostics, or to display information on the last card or fob detected by the card
reader.

Summary of Contents for K-1205-IP Series

Page 1: ...terproof scratch resistant lens and 12 buttons for single push auto dialing of a tenant s phone number or business extension When the K 1205 IP phone is connected to an apartment or business tenant a...

Page 2: ...to www vikingelectronics com and enter 944 in the search box 2 Click Application Note DOD 944 to open and download the PDF Scan the QR code below to open and download the Viking VoIP SIP System Compat...

Page 3: ...address also called a hardware address or physical address is a unique address assigned to a device at the factory It resides in the device s memory and is used by routers to send network traffic to...

Page 4: ...ded or program as a output to connect to the card reader input of an Access Control System Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire...

Page 5: ...al St Hudson WI 54016 DEV RoHS J6 Q171570 8 2W J6 MAC 18E80FXXXXXX asdesaxtff Note Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable Longer cable runs can be used if a pass...

Page 6: ...nt the directory lens to the front of the K 1205 IP using the included Allen wrench Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the nam...

Page 7: ...TUS LED Optional Viking model RC 4A Secure Remote Relay Controller see page 7 DOD 582 Extends range of cable keeps 1 Gbps network speed for other equipment on network IBM compatible personal computer...

Page 8: ...you to trouble shoot the failure B Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the net...

Page 9: ...ettings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for...

Page 10: ...ld the key on keypad then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold key until you hear 2 beeps approximately 6 seconds Continue to hold key until you hear 4 more beeps approximately 6...

Page 11: ...must be set to Door Strike 22 18 In Band Audio Call Progress Enabled Disabled factory set to Enabled 23 18 In Band Audio Detect Sensitivity 1 9 1 minimum 9 maximum factory set to 5 power cycle unit a...

Page 12: ...field blank 1 Unit Name Up to a 31 character unit name can be assigned to the K 1205 IP Series Phone being programmed When registered to a SIP server in the event that registration is lost you can pro...

Page 13: ...he PC and are not uploaded The Index Number is the single digit number visitors enter on the K 1205 IP s keypad for the unit to call the tenant 3 seconds after the number is entered the unit will then...

Page 14: ...ion which door gate was opened or closed entry code index and phone number index with tenant name The Event Log can store up to 4 095 events Events are stored in a first in first out format When the m...

Page 15: ...ty Card entries but also log any errors incorrect codes or non valid card reads Keyless Entry Code and Proximity Card logging can also be set to Live Logging With Live logging selected and the K 1205...

Page 16: ...er is sent over the Weigand output along with the facility code selected Since Wiegand data limits the entry code to 65535 maximum plus entry codes higher than 65535 are not sent over the Wiegand outp...

Page 17: ...r strike relay is activated After the called party enters the correct relay activation command the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound rel...

Page 18: ...utomatically decrease When background noise decreases the mic gain will automatically increase The Auto mode is useful in applications where the background noise level can change drastically such as a...

Page 19: ...dialing 9 from the connected phone If enabled and a busy is detected the K 1205 IP phone will dial the Roll Over speed dial number Factory Setting Enabled Note If the busy signal is interrupted with...

Page 20: ...d like to update firmware An alternative method of updating can be done by clicking the IP firmware Update IP button You can then browse to the folder that contains the PIP file for updating the unit...

Page 21: ...ne of the following actions based on the Relay Mode settings for each relay see section 22 Relay 1 Door Strike relay 2 other Relay 1 will be activated for the programmed Relay 1 Activation Time Relay...

Page 22: ...mber can be programmed to activate relay 1 and or 2 in four different relay modes Momentary Latch Un Latch and Toggle To use a proximity card the tenant simply presents a preprogrammed proximity card...

Page 23: ...netic Lock 120V AC Door near Entry Phone 3 1 IN1 C IN2 IN3 C IN4 2 3 4 5 6 Relay 1 Output Contacts 5A 30VDC 250VAC max Connect to Doorstrike Mag Lock Gate Controller etc Relay 3 Output Contacts 5A 30V...

Page 24: ...The use of magnets to mount the VE Series enclosure to a metal surface can affect the operation of the enclosed product Caution Handsfree phones are not suitable for noisy applications see Important...

Page 25: ...r strikes and gates when a remote relay is required for security reasons It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs Two RC 4...

Page 26: ...the dispatcher the reason for the call Perform such tests in off peak hours such as early morning or late evenings PART 15 LIMITATIONS This equipment has been tested and found to comply with the limi...

Reviews: