Viking FGIM515 Installation Manual Download Page 15

15

Gravity Drain Pump Model drain installation

1. Place the ice machine in front of the installation opening. Adjust leveling legs to the approximate height.
2. Remove the front service access panel and the upper back panel (if necessary).

Note:

If you are connecting a gravity drain model and the drain opening has been located in the floor under the base

pan according to the pre install specifications, follow steps 3 through 5 to drain the unit through the base. If not,
proceed to step 6b.

3. Remove the clamp and barbed elbow and take off the plastic cover in the base pan below the drain hose.
4. Connect a straight 5/8” barbed connector to the drain hose, securing with the clamp removed in step 4.
5. Cut an 8” piece of 5/8” ID X 7/8” OD tygon (clear plastic) tubing. Slide one end of the tube onto the outlet of the

barbed connector and secure with a clamp. Leave the other end of the tube lying on the floor of the base pan until
the unit is positioned over the floor drain.

6. Route the drain tube. Either a) Insert the drain tube through the base pan into the floor drain or b) Route the drain

tube through the left hole in the lower back panel and connect to barbed elbow and secure with a clamp.

7. Reinstall the upper back panel (if removed in step 2).
8. Reinstall the service access panel. Level the unit.

Back View, Gravity Drain Model

Water Inlet
Tube (field
supplied)

Drain Hose

Barbed Elbow

Drain Hose,
Route to
building drain

CAUTION

Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing
must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code.

Summary of Contents for FGIM515

Page 1: ...15 W Undercounter Freestanding Ice Machine Installation FGIM515 CFGIM515 FPIM515 CFPIM515...

Page 2: ...___________________________________________________9 Installation Overview_______________________________________________________________________________________10 Accessory Door Panel________________...

Page 3: ...ended Rated for Class A 5 mA 1 mA trip current as per UL 943 standard In good condition and free from any loose fitting gaskets if applicable in outdoor situations Protected from moisture water steam...

Page 4: ...on units are still dangerous even if they will sit for just a few days IMPORTANT Now that you have a new ice machine it is extremely important that you dispose of your old appliance in a way that mini...

Page 5: ...e 90 0 115 0 37 3 4 95 9 cm 2 1 2 6 4 cm 22 3 4 57 8 cm 20 3 8 51 6 cm Dimensions FGIM FPIM w Professional door panel Door Swing 19 1 4 48 9 cm 22 3 4 57 8 cm 25 1 4 64 1 cm 33 7 8 86 0 cm min to 34 7...

Page 6: ...8 86 0 cm min to 34 7 8 88 6 cm max 14 7 8 37 8 cm 14 7 8 37 8 cm 14 7 8 37 8 cm 30 5 16 77 0 cm 14 3 4 37 5 cm 3 7 8 9 8 cm Floor drain access hole 90 0 37 3 4 95 9 cm 22 3 4 57 8 cm 20 3 8 51 6 cm 9...

Page 7: ...epth 24 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 6 3 wire cord attached to product Maximum amp usage 5 0 amps Inlet water requirement 1 4 OD copper tubing inlet waterline 20...

Page 8: ...CAL LOCATION Drain Flexible tubing 3 8 ID pump model included 5 8 ID x 7 8 OD gravity model not included Potable water inlet 1 4 compression fitting 3 1 4 8 3 cm 2 1 2 6 4 cm 1 1 2 3 8 cm 3 3 4 9 5 cm...

Page 9: ...hate feeders RO Water This machine can be supplied with Reverse Osmosis water but the water conductivity must be no less than 10 microSiemens cm A reverse osmosis system should include post treatment...

Page 10: ...n for later use 2 If the door panel is stainless steel remove any plastic covering the stainless steel panel 3 Place the panel onto the outside of the door and secure it to the door using two machine...

Page 11: ...of panel will be flush with top of door Measure hole locations from the top of the panel 9 Drill pilot holes for wood screws Use drill stop to prevent drilling through the panel 10 Mount panel to doo...

Page 12: ...12 DOOR PANEL ATTACHMENT Gasket Accessory Door Panel Cover Machine Screw Use Upper Hole at the Top Use Lower Hole at the Bottom Hole Plug...

Page 13: ...some situations the door can open too far and damage adjacent cabinets To prevent that insert a stop into the provided hole in the top and bottom hinges Drive the pin into the hole until the head is a...

Page 14: ...a compression fitting on the tubing and connect to the inlet of the solenoid fitting is located in cloth bag behind access panel DRAINS There are two types of ice machine models one that drains by gra...

Page 15: ...clear plastic tubing Slide one end of the tube onto the outlet of the barbed connector and secure with a clamp Leave the other end of the tube lying on the floor of the base pan until the unit is pos...

Page 16: ...n on drain pump equipped machines the drain pump should start and water should pump out Check for leaks 7 Replace the service access panel and insert access panel button cover supplied 8 Level the uni...

Page 17: ...below You will need it if service is ever required The model and serial number for your ice machine are located upper left interior compartment Model Number ____________________________________Serial...

Page 18: ...18...

Page 19: ...19...

Page 20: ...6 01 040116 Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com in the US or brigade ca...

Reviews: