47
High Voltage Board
Component
Test
Point
Reading
Refrigerator/Con-
densate Fans
E1-E11
24 VDC
Evaporator Fans
E2-E11
115 VAC
L1
E3-E11
115 VAC
Compressor / Con-
denser Fan
E4-E11
115 VAC
Defrost Terminator
(closed)
E5-E11
0 VAC
Defrost Terminator
(open)
E5-E11
115 VAC
Defrost Heater
E6-E11
115 VAC
Ref door switch (top
right light)
E7-E11
115 VAC
Freezer door switch
(left light)
E8-E11
115 VAC
Neutral In
E9-E11
N/A
Line In
E10-E11 115 VAC
Ground
E11
N/A
Neutral In (lights)
E12-E11 N/A
Neutral Out (lights)
E13-E11 115 VAC
Aux Heater (Dis-
penser units only)
E14-E11 115 VAC
E11 Ground
E1 Refrigerator/
Condensate Fans
E4 Compressor
E3 Line In–120 VAC
E2 Evaporator Fan
E7 Refrigerator Door
Switch
E8 Freezer Door Switch
E9 Neutral
L1 Line In - 120 VAC
E5 Defrost Terminator
E6 Defrost Heater
E12 Neutral in
E13 Light Relay
E14
E14 Aux Heater
High Voltage Board
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!