Service Procedures
34
©2012 Viking Preferred Service
LOWER
HIGHER
REF
TEMP
MAX
FRZ
HIGHER
LOWER
LOWER
HIGHER
MAX
REF
FAST
COOL
HIGHER
LOWER
While in Mode B, press and
release "MAX FRZ" one time,
this will result in "MAX FRZ"
illuminating on the display along
with the current numeric value in hours that
MAX FRZ is set at. Factory default for this
adjustment is 6 hours. Range is 1 to 20 hours
in 1 hour increments.
The duration is adjusted using the
"HIGHER and LOWER" pads.
This value should be set at -8
o
F,
use "HIGHER or LOWER" pads to
adjust to this value.
Adjust Refrigerator Temperature Offset
Refrigerator temperature offset is a
predetermined value, based upon model of
refrigerator. This value can be set in Mode
B as a separate adjustment or can be set
automatically in Mode B when selecting
model code, where several control values
are set by eeprom. Table 1 on Page 42 lists
eeprom values set by model code.
Press and release "REF TEMP"
pad once, the "REFRIGERATOR"
indicator will illuminate and the
current refrigerator offset will be
displayed along with
o
F.
Adjust MAX FRZ duration
Adjust MAX REF duration
While in Mode B, press and
release "MAX REF" one time,
this will result in "MAX REF"
illuminating on the display along
with the current numeric value in hours that
MAX REF is set at. Factory default for this
adjustment is 4 hours. Range is 1 to 20 hours
in 1 hour increments.
The duration is adjusted using the
"HIGHER and LOWER" pads.
Adjust FAST COOL duration
While in Mode B, press and
release "FAST COOL" one time,
this will result in "FAST COOL"
illuminating on the display along
with the current numeric value in hours that
FAST COOL is set at. Factory default for this
adjustment is 2 hours. Range is 1 to 20 hours
in 1 hour increments.
The duration is adjusted using the
"HIGHER and LOWER" pads.