Viking F20518A Installation Manual Download Page 8

Installation

15

14

General Information

READ AND FOLLOW ALL WARNING
AND CAUTION INFORMATION WHEN
INSTALLING THIS APPLIANCE.

• All openings in the wall behind the

appliance or in the floor under the
appliance should be sealed.

• Keep appliance area clear and free from

combustible materials, gasoline and other
flammable vapors.

• Disconnect the electrical supply prior to

servicing or cleaning.

• When removing the appliance for cleaning

or service, disconnect AC power supply
and carefully remove the appliance by
pulling forward.

• Electrical requirements are listed in the

product specifications under the “Electrical
& Gas Requirements” section.

• Do not obstruct the flow of combustion and

ventilation air.

Moving, Handling, and Unpacking

Remove and discard all packing materials,
including cardboard and tape on the outside
and inside of the ovens.

Some stainless steel parts may have a plastic
protective wrap which must be peeled off.
The interior should be washed thoroughly
with hot, soapy water to remove film
residues and any dust or debris before being
used, then rinsed and wiped dry. Solutions
stronger than soap and water are rarely
needed.

Recommendations for Unpacking

• Products are shipped on pallets with foam

footings and corrugated inner-packing and
exterior hoods.

• Products are anchored to the pallet using

metal straps that are screwed to the
bottom of the product and the pallet.

DO NOT

remove protective packaging

until you are ready to perform the
installation.

• To remove the packaging, first remove the

staples located at the bottom perimeter of
the corrugated cover.

• Remove the corrugated cover by lifting it

off the product and remove the inner-
packing.

• Detach the product from the metal anchor

strip by removing the attachment screw.

• If installing a warming drawer beneath the

oven or a microwave above the oven, then
it is necessary to have a minimum of 2”
spacing between the oven and the
adjacent product for ventilation purposes.

• It is recommended that 3/4” or larger

material be utilized to create a support
platform for this appliance.

BE SURE

that support for this appliance is

perpendicular to the front facing of the
wall or cabinet before you perform the
installation.

• Use of a hydraulic lift is recommended for

the installation of double oven units.

• All openings in the wall behind the

appliance or in the floor under the
appliance should be sealed.

• Keep appliance area clear and free from

combustible materials, gasoline and other
flammable vapors.

WARNING: DO NOT

USE AN

EXTENSION CORD WITH THIS
APPLIANCE. SUCH USE MAY RESULT IN
FIRE, ELECTRICAL SHOCK OR OTHER
PERSONAL INJURY.

CAUTION

Avoid any damage to oven vents. The vents

need to be unobstructed and open to provide

proper airflow for optimal oven performance.

CAUTION

The cooling fan should be operating when

the unit is in operation. If you notice the

cooling fan is not operating or you observe

unusual or excessive noise coming from the

cooling fan, contact a Viking Authorized

Service Center before continuing operation.

Failure to do so can result in damage to the

oven or surrounding cabinets.

General Information

(cont.)

Recommendations for Moving

• The appliance is heavy – use extreme care

when handling!

NOTICE

DO NOT

use the handle or oven door to

lift the oven. Remove door before

installation to ensure that it is not used to

lift the unit.

DO NOT

lift or carry the door

by the handle.
Removing the door must be done by your

dealer, a qualified licensed plumber, or

certified gas installer.

• Only proper equipment should be used to

move products.

ALWAYS

take steps to protect flooring at

the installation location when moving
products.

Site Preparation

Note:

It is recommended that a thorough

site inspection be conducted PRIOR to
unpacking and moving this appliance.

WARNING: DO NOT

use the handle or

oven door to lift the oven. Remove door
before installation to ensure that it is not
used to lift the unit. Make sure pins are
inserted into hinges before removing door
to prevent personal injury to hands and/or
fingers.

Do not lift or carry the door by

the handle.

• Confirm available access to adequate

power – see electrical requirements.
–Single oven units require a 30 amp circuit
–Double oven units require a 50 amp

circuit

Summary of Contents for F20518A

Page 1: ...Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20518D EN 070209J Viking Installation Guide Professio...

Page 2: ...______________________________25 Final Preparation ___________________________________________________________________26 Performance Checklist _________________________________________________________...

Page 3: ...NING Moving hazard To avoid risk of severe personal injury this appliance requires two or more personnel while handling and moving Possible use of appliance moving devices is recommended WARNING The u...

Page 4: ...g attached to product Flexible cord connector must be 1 2 ID 1 3 cm Cord must be agency approved for use with household gas ovens Maximum amp usage 1 2 amps Infrared broil burner rating 18 000 BTU Nat...

Page 5: ...d natural or LP Propane gas LP must be specified after color code accepts standard residential 1 2 1 3 cm ID gas service line Gas manifold pressure Natural 5 0 W C P Liquid propane L P 10 0 W C P Elec...

Page 6: ...8 9 cm 17 43 2 cm min 30 76 2 cm Recommended 3 7 6 cm 3 1 2 8 9 cm 3 1 2 8 9 cm 3 1 2 8 9 cm Gas inlet location Gas inlet location Gas inlet location 1 1 7 8 3 0 2 c m Gas inlet location Gas inlet loc...

Page 7: ...lways check for gas leaks with a soapy water solution or other acceptable method DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS Clearance Dimensions 12 Note Door handle of oven should be 36 91 4 cm above...

Page 8: ...to create a support platform for this appliance BE SURE that support for this appliance is perpendicular to the front facing of the wall or cabinet before you perform the installation Use of a hydrau...

Page 9: ...ock hazard To avoid the risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Elect...

Page 10: ...adjustment screw clockwise up or counterclockwise down Close door Door Replacement Adjustment 30 W 18 1 2 Remove racks Unscrew pallet screws from side of oven 3 4 Lift oven into position Push oven str...

Page 11: ...ectrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest...

Page 12: ...ex tubing through 2 hole and attach to the male connector Replace access panel Push lower oven straight into cabinet Note Purchase necessary gas kit IKD VGSO 22 1 2 3 4 5 6 Final Installation 36 W Sin...

Page 13: ...0 Connect gas line and check for leaks 11 12 Final Installation 36 W Double cont Remove all knobs push buttons bezels and lower access panel side trim and control panel Remove control box disconnectin...

Page 14: ...ter Off On Indicator light Interior Oven Light Control Temperature Control Oven Function Selector Oven Function Selector Oven Light Button VGSO100 VGSO166 Service Codes VGSO166 The Time Temperature di...

Page 15: ...____________ Serial number _____________________________________________________________________________________ Date of purchase ______________________________________________________________________...

Page 16: ...31 30...

Reviews: