Viking E-65-SS Technical Manual Download Page 7

This feature selects the length of time that calls will remain connected without voice activity.  Programmable in incre-
ments of 10 seconds up to a maximum of 90 seconds.  To disable the silence time out, program ten ones in the “

Time

value location.  Use the chart at the right.  * 

Note:

The factory default is 40 seconds.

D. Accessing the Programming Mode

Step 1. 

Move DIP switch 1 to the 

ON

position (sets unit to answer incoming calls - see section 

C

).

Step 2.

Move DIP switch 3 to 

ON

(incoming calls automatically enter the programming mode - see section 

C

).

Step 3.   

From a Touch Tone phone call the line attached to the 

E-65

.

Step 4. 

When the 

E-65

answers, 2 beeps will be heard and you will automatically enter the programming mode.

Step 5. 

When finished programming, enter “

0000

” to exit programming and move DIP switch 3 back to 

OFF

(see section 

C

).

The 

E-65

can be programmed from any Touch Tone phone using a telephone line, Viking model 

C-200, C-250, C-500

or

C-2000B

Entry Phone Controller, analog PABX/KSU station or a Viking model 

DLE-200B

Line Simulator.

This feature selects the maximum length of time that calls can be con-
nected. Programmable in increments of 1 minute up to a maximum of
9 minutes. To disable the call length time out, program ten ones in the

Time

” value location.  With the call length disabled, the 

E-65 

phone

must rely on CPC, busy, silence or return dial tone to hang-up.  Use
the chart at the right.

Note:

The factory default is 5 minutes.

Time

Value

1

11

111

1111

11111

111111

1111111

11111111

111111111

10 or more

Call Length

Time Out

1 min
2 min
3 min
4 min

5 min*

6 min
7 min
8 min
9 min

Disabled

E. Quick Programming Features

Call length time out (1-9 minutes), 10 = disabled (factory set to 11111 = 5 minutes) .......................................
Silence time out for disconnect (10-90 seconds), 10 = disabled (factory set to 1111 = 40 secs) .....................
Talk/listen delay (VOX switching speed) 0.1 - 0.9 seconds (factory set to 111 = 0.3 secs) .............................
Forced hang-up command (used to exit programming and hang up the 

E-65

) ..............................................

0
00
000
0000

111...
111...
111...

Select

Feature

beep
beep
beep

3 beeps

Wait for
Beep(s)

Enter

Time Value

beep beep
beep beep
beep beep

Wait for

2 Beeps

F. Programming Beeps

If a valid “

Feature

” is entered, a single beep will be heard and you will have 20 seconds to enter a “

Time

” value. If an

invalid “

Feature

” (five or more zeros) or forced hang-up command (four zeros) is entered, 3 beeps will be heard and

the 

E-65

will hang up.  If a valid “

Time

” is entered 2 beeps will be heard and you will have 20 seconds to enter your

next “

Feature

”. If an invalid “

Talk/Listen Delay Time

” is entered (10 or more ones), 3 beeps will be heard and you will

have 20 seconds to enter your next “

Feature

”. 

G. Call Length Time Out

H. Silence Time Out

Silence

Time Out

10 sec
20 sec
30 sec

40 sec*

50 sec
60 sec
70 sec
80 sec
90 sec

Disabled

Talk/Listen

Delay

.1 sec
.2 sec

.3 sec*

.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec

Error

This feature selects switching time between talk and listen modes (VOX switching time).  Use the chart above.  

Note: 

The factory default is .3 seconds.

I. Talk/Listen Delay (VOX Switching Speed)

See

Table A

in section

G

Table A

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

When the push button is pressed, the 

E-65

phone goes off-hook, much like a standard speaker phone.  In the event that

the line is busy, the 

E-65

will hang-up.  The 

E-65

will also automatically hang up on CPC, silence, busy signal, return to dial

tone or time out. If programmed to auto-answer (DIP switch 1 

ON

), the 

E-65

will also answer any incoming call. 

The 

E-65

color video camera operates completely independently of the 

E-65

phone board. With power supplied to the cam-

era, it will continuously output a video signal.

7

Summary of Contents for E-65-SS

Page 1: ...t camera lens hex drive mounting screws Weather Resistant Features Mylar speaker faceplate gasket mic and speaker gasket internally sealed IP67 push button switch sealed camera lens potted camera circ...

Page 2: ...03 is a REN of 0 3 For earlier products the REN is separately shown on the label The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable F...

Page 3: ...all applications caulk around the box filling any gaps between the box and the rough opening Apply caulk to any holes in the box around wires etc F Fe ea at tu ur re es s O Ov ve er rv vi ie ew w Face...

Page 4: ...l surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect against such surges Circuit Board Mounting Plate included 1 4 Thick Foam Facepl...

Page 5: ...o prevent the edge of the faceplate from being viewed in the video image do not rotate the cam era beyond 30 degrees or tilt beyond 20 degrees Vertical Tilt Adjustment 20 degrees maximum Horizontal Ro...

Page 6: ...in the ON position if the E 65 detects more than 5 seconds of continued dial tone the unit will automatically disconnect If the E 65 is installed on a continuously noisy line it may detect the noise a...

Page 7: ...11111 5 minutes Silence time out for disconnect 10 90 seconds 10 disabled factory set to 1111 40 secs Talk listen delay VOX switching speed 0 1 0 9 seconds factory set to 111 0 3 secs Forced hang up...

Page 8: ...xiliary output is also available Earth Ground optional Optional Doorbell Switch not included see Programming section L on page 5 Optional Postal Lock not included See DIP Switch Programming Programmin...