VIKING

Model:

XXXXXXX

xxxxxx

S/N:

REN 0.8A:

XXXXXXXX

V

iking Electronics, Inc.    (715)  386-8861

1531 Industrial St., Hudson, WI  54016

P/N:

DEV

:

Complies with FCC Part 15 and 68 Reg. No: US:AH3TE08A22264

LED3

LED1

LED2

LED4

LED5

LED6

LED7

C

C

C

C

C

C

C

J11-

1

2

3

J10-

1

2

3

J9-

1

2

3

J8-

1

2

3

J7-

1

2

3

12

3

on

4

5

VIKING

©

MODEL C-2000B 

VIKING

ELECTRONICS

HUDSON, WI  54016

ADVANCED DOOR/GATE AND
ENTRY PHONE CONTROLLER

1     2     3     4     5     6     7

8 9 1 0 11 12 13

15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

PWR 13.8 V

A

C

EARTH GND

ENTR

Y

 PHONE 1

DOOR STRIKE 1

ENTR

Y

 PHONE 2

DOOR STRIKE 2

ENTR

Y

 PHONE 3

DOOR STRIKE 3

ENTR

Y

 PHONE 4

DOOR STRIKE 4

DOORBELL

 SWITCH /

AUX. INPUT

AUX. CONT

ACT

OUTPUT

PHONE LINE

INPUT

LINE OUT

T

O

 PHONES

ANALOG ST

A

TION

INPUT

VIKING

©

DLE-200B

RES

RINGDOWN

BUSY

1

2

VIKING

©

Programmable

Tone Dialer

MODEL:  K-1900-5

Quick Programming Guide

1.  Call the phone connected to the dialer.
2.  Answer phone.  Enter 

*

 & security code.

     (Factory set to 845464)  Write your
     security code below:

3.  Enter your spped dial number & #00.
Note: For additional programming see
          K-1900-5 Technical Practice.

Viking Electronics, Inc.

Hudson, WI  54016

LINE IN                      PHONE

Red

(Ring)

Green

(Tip)

** Earth
Ground

(optional)

(Ring

connector

included)

Rear View of the
E-65 Circuit Board
Mounting Plate

-or-

* Gel-Filled

Butt Connectors

(included)

E-65 is not

polarity sensitive

Viking C-200, C-250, C-500 or C-2000B 

Entry Phone Controller (not included)

*** Optional Viking

K-1900-5 Dialer or

K-1900-30 Multi-

Number Dialer

(not included)

**** C.O. Line

or  Analog 

PABX/KSU Station 

(programmed for 

ringdown)

Viking DLE-200B

Two Way Ringdown

Circuit (not included)

To dedicated phone, unused trunk/

line input of a phone system, or

Viking C-1000B Doorbox Controller

*** Note: 

Talk battery must be a minimum of 28V DC when using the speaker phone with a Viking 

K-1900-5

Dialer (

DOD# 317

) or 

K-1900-30

Multi-Number Dialer (

DOD# 300

).

** Note:

To increase surge protection, loosen the PCB mounting screw labeled           (as shown above) and fasten a wire with ring terminal (included) from the mount-

ing screw to Earth Ground (grounding rod, water pipe, etc.) After fastening ring terminal to PCB mounting screw, bend terminal up to avoid interference with single
gang box.

* Note:  

The gel-filled (water-tight) butt connectors (3M Scotchlok UR2) are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of

0.082 inches. Do not  strip wires prior to terminating.

**** Note: 

When installing a line powered phone on a low voltage and/or low loop current phone system extension, a Viking 

TBB-1B

Talk Battery Booster may

be required, see 

DOD# 632

.

E. Wiring the E-65 Phone Board

IMPORTANT:

Electronic devices are susceptible to lightning and power station elec-

trical surges from both the AC outlet and the telephone line.  It is recommended that a
surge protector be installed to protect against such surges. 

!

Circuit Board 

Mounting Plate

(included)

1/4" Thick Foam 

Faceplate Gasket

(included)

Facplate

(included)

(4) 6-32 x 1.25" Long 

5/64" Hexdrive 

Flathead Screws 

(included)

"Old Work" Double Gang Rough-In 

Box with minimum dimensions of: 

3.65"W x 2.84"H x 2.25"D. (Carlon 

BH234R box shown, not included)

Optional VE-5x5 Surface Mount Box 

with Black Satin Powder Paint Finish, 

not included (DOD# 424) WARNING: 

Do NOT use a wet location box.

2.25”

5.14”

5.22”

3.25”

3.63”

3.63”

-OR-

(2) Junction Box to 

Double Gang Adapter 

Plates and (4) 5/64 Hex 

Drive Flat Head Screws 

(included with the E-65)

*2.25"

Deep

Min.

** LED

Light Pipe
(included)

(5) 3-Wire Gel-Filled

Butt Connectors

(included)

     Green

Red

Wires from

Phone Board

Wires from

Camera

     Red

   Black

Yellow

CAT5E

Cable

W/BL

Blue

Orange

 W/O

         Green

W/G

Wing Brackets

C. Surface Mounting

D. Mounting the Faceplate

A Viking model 

VE-5x5

can be used to surface mount an 

E-65

to a wall or post. Recommended mounting height to bot-

tom of 

VE-5x5

is 50” - 54”. Drill a small wire exit hole in wall. Pull wire through and seal hole around wire with putty or

caulking. Route wire into the 

VE-5x5

box, securely screw it to wall or post and seal hole in box around wire with putty

or caulking. 

Note: 

Conduit may also be used when surface mounting wire, but should not enter through the top of the

VE-5x5

. When routing wiring from above, a drip loop is required. 

WARNING:

Do 

NOT

use a typical “wet location box”

as not all styles seal properly with the 

E-65

faceplate.

After the Rough-In box or 

VE-5x5

is securely mounted, caulking between the box and rough opening is completed (if

required), wires are connected, and camera is tilted and rotated to the desired position (as shown in section 

G

).

Remove paper liner from face plate gasket and place it on back side of face plate aligning with push button hole. Push
the 1-1/4" 6-32 screws through faceplate holes and small holes in gasket, the faceplate gasket should retain the
screws. Position the circuit board mounting plate over screws. Align screws with double gang box bosses and tighten
face plate until gasket is fully collapsed and the push button is protruding through the clearance hole in the face plate.
Included 1/4" thick gasket will provide an adequate seal for most siding surfaces; however for rough surfaces (ie: brick,
stucco, etc.) additional caulking may be required. 

4

* CAUTION:

Excessive wire length and/or using a

rough-in box with inadequate depth can apply force
to the circuit board causing physical damage.

** Important:

Push LED light pipe into faceplate hole, then place faceplate

upside down on a clean flat surface and push down on back side of plate
until light pipe is fully seated and straight. 

WARNING:

Inserting the light pipe

more than one time can cause a loose fit.

Summary of Contents for E-65-SS

Page 1: ...t camera lens hex drive mounting screws Weather Resistant Features Mylar speaker faceplate gasket mic and speaker gasket internally sealed IP67 push button switch sealed camera lens potted camera circ...

Page 2: ...03 is a REN of 0 3 For earlier products the REN is separately shown on the label The plug used to connect this equipment to the premises wiring and telephone network must comply with the applicable F...

Page 3: ...all applications caulk around the box filling any gaps between the box and the rough opening Apply caulk to any holes in the box around wires etc F Fe ea at tu ur re es s O Ov ve er rv vi ie ew w Face...

Page 4: ...l surges from both the AC outlet and the telephone line It is recommended that a surge protector be installed to protect against such surges Circuit Board Mounting Plate included 1 4 Thick Foam Facepl...

Page 5: ...o prevent the edge of the faceplate from being viewed in the video image do not rotate the cam era beyond 30 degrees or tilt beyond 20 degrees Vertical Tilt Adjustment 20 degrees maximum Horizontal Ro...

Page 6: ...in the ON position if the E 65 detects more than 5 seconds of continued dial tone the unit will automatically disconnect If the E 65 is installed on a continuously noisy line it may detect the noise a...

Page 7: ...11111 5 minutes Silence time out for disconnect 10 90 seconds 10 disabled factory set to 1111 40 secs Talk listen delay VOX switching speed 0 1 0 9 seconds factory set to 111 0 3 secs Forced hang up...

Page 8: ...xiliary output is also available Earth Ground optional Optional Doorbell Switch not included see Programming section L on page 5 Optional Postal Lock not included See DIP Switch Programming Programmin...

Reviews: