PUSH FOR
VIKING
©
HELP
MODEL E-1600A-TP
EMERGENCY
PHONE
CONNECTED
CALL
"Call Connected" LED
Push for "Help" Button ("Info" Button
available on model E-1600A-TP2-EWP)
Marine grade 316 stainless steel faceplate
and push button switch (sealed per IP67)
Grade 2 Braille Label
(6) 0.250 diameter counter sunk 82° x 0.410
diameter holes for flathead #10 x 24
tamper-proof screws (not included)
7.750
4.00
2.75
9.50
10.250
0.875
11.75
5.125
Typ
0.75
4.50
2.125
2.75
0.75
Minimum Cutout
5.125
S1
1
2
ON
3
11
10
9
8
7
6
5
4
3
2
1
Rear View of the
E-1600A-TP-EWP Phone Panel
Ring Connector
(included)
* Earth Ground
(optional)
1600A Emergency
Phone Board
LDB-3 Control
Module
** Gel-Filled Butt
Connectors (included)
Note: Polarity Sensitive!
(-) Black with
White stripe
120V AC
(+) Red with
Black stripe
(+) Black
Red (+)
Black (-)
Green with Yellow stripe
Red with Yellow stripe
Auxiliary
Contact Output
Blue
Blue
Incoming
Analog Phone
Line
Disable Feature
(see Programming section F)
Purple
Orange
Yellow
N.C.
COM.
N.O.
12V DC
Adapter
Included
(-) Black with
White stripe
Positions 3 and 4 come factory
wired directly to the 1600A
Emergency Phone Board
Red
Green
*** Drip
Loop
*** Drip Loop
S1
1
2
ON
3
11
10
9
8
7
6
5
4
3
2
1
Switched 12VDC (350mA
maximum) Output
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
A. Wiring
IMPORTANT:
Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended
that a surge protector be installed to protect against such surges.
!
(+) Black
(-) Black with
White Stripe
Step 1.
Step 2.
Step 3.
IMPORTANT:
Do
NOT
plug in the
adapter until after
Step 3
is completed.
Step 1.
Cut off the barrel connector.
Step 2.
Seperate the wires.
Step 3.
Connect 12V adapter wires to power supply wires
on the
LDB-3
Control Module using the supplied
butt connectors and then plug in power supply.
Preparing the Power Supply
Connect power supply
wires to
LDB-3
module
power supply wires
B. Mounting
* Note:
To increase surge protection, loosen the PCB mounting screw labeled (as shown) and fasten a wire with ring connector (included) from the
mounting screw to Earth Ground (grounding rod, water pipe, etc.)
** Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inch-
es. Cut off bare wire ends prior to terminating.
*** Note:
When wires are routed from above, a “drip loop” is recommended to keep water away from the circuit board.
3