background image

Specifications

8

Designer Electric Cooktops

Description

DETU200-4B

DETU260-5B

Overall width

30-3/4” (78.1 cm)

36-3/4” (93.3 cm)

Overall height (from top of
cooktop to bottom of conduit)

4-1/4” (10.8 cm)

Overall depth from rear

21” (53.3 cm)

Cutout width

28-3/4” (72.9 cm) min. to

29” (73.7 cm) max.

34” (86.4 cm) min. to

34-9/16” (87.8 cm) max.

Cutout height

3-1/8” (7.9 cm)

Cutout depth

19-1/4” (49.0 cm) min. to

19-5/8” (49.8 cm)

Electrical requirements

3-wire, 240-208/120VAC/60Hz;

40 amp connection. Unit is equipped with

No. 10 ground wire in conduit. Should be fused

separately.

3-wire, 240-208/120VAC/60Hz;

60 amp connection. Unit is equipped with

No. 10 ground wire in conduit. Should be fused

separately.

Maximum amp usage

240V—35.0 amps (8.4 kw)
208V—30.3 amps (6.3 kw)

240V—45.0 amps (10.8 kw)

208V—40.0 amps (8.3 kw)

Surface element rating

Left front

Bridge

Left rear

Center

Right front

Right rear

240V

208V

1,800 watts

1,350 watts

800 watts

600 watts

1,800 watts

1,350 watts

1,500 watts

1,125 watts

N/A

N/A

2,500/1,600/800 watts 1,875/1,200/600 watts

240V

208V

1,800 watts

1,350 watts

800 watts

600 watts

1,800 watts

1,350 watts

2,500/1,600/800 watts 1,875/1,200/600 watts

1,500 watts

1,125 watts

2,100 watts

1,575 watts

Approximate
shipping weight

35 lb. (13.1 kg)

60 lb. (27.2 kg)

Summary of Contents for Designer DETU200

Page 1: ...Viking Installation Guide Designer Built In Electric Cooktops...

Page 2: ...__________________9 Clearance Dimensions Wood Composite or Steel Overlay ______________________________11 Electrical Requirements _____________________________________________________________12 Genera...

Page 3: ...ational Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 Installers should leave these instructions w...

Page 4: ...n This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle DO NOT cut or remove the grou...

Page 5: ...G It is the customer s responsibility to contact a qualified electrical installer To assure that the electrical installation is Adequate and in conformity with national electrical code ANSI NFPA 70 la...

Page 6: ...Dimensions 6 21 53 3 cm 30 3 4 78 1 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 28 71 1 cm 18 9 16 47 2 cm 12 30 5 cm 3 1 4 8 3 cm Power conduit 30 Electric Cooktop Note Dimension includes screw head...

Page 7: ...Dimensions 7 21 53 3 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 36 3 4 93 4 cm 33 3 8 84 7 cm 18 9 16 47 2 cm 3 1 4 8 3 cm Power conduit 12 30 5 cm 36 Electric Cooktop Note Dimension includes screw head...

Page 8: ...uld be fused separately 3 wire 240 208 120VAC 60Hz 60 amp connection Unit is equipped with No 10 ground wire in conduit Should be fused separately Maximum amp usage 240V 35 0 amps 8 4 kw 208V 30 3 amp...

Page 9: ...9 16 87 2 cm max B 19 1 4 49 0 cm min to 19 5 8 49 8 cm max Cutout Dimensions Note Refer to the downdraft installation instructions Downdraft Dimensions DETU200 w DIPR100 DETU260 w DIPR160 A 28 3 4 73...

Page 10: ...e vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wa...

Page 11: ...1 4 cm Wall Installation Island Installation Clearance Dimensions Wood Composite or Steel Overlay The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This wou...

Page 12: ...ation Batter march Park Quincy Massachusetts 02269 A three wire single phase 240 Volt 60 cycle electrical system properly circuit protected to meet Local Codes of NFPA No 70 must be provided Unit must...

Page 13: ...nch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire gray or white colored wire proceed as follows 1 If local codes permit connect the...

Page 14: ...s All wall coverings countertop and cabinets around the cooktop should withstand heat up to 200 F 90 C Keep appliance free from combustible materials gasoline and other flammable vapors Installation P...

Page 15: ...ds beyond the outermost flange of the cooktop All corners should be covered with tape IMPORTANT 1 2 Optional Gasket Turn the cooktop upside down and place on the packaged foam top Note Make sure there...

Page 16: ...to the corresponding leads in the junction box Electrical Connection Final Installation 3 wire 1a Neutral Green Black Red Connect the red and black leads from the unit conduit to the corresponding le...

Page 17: ...to remove these film residues and any installation dust or debris before being used for food preparation A qualified installer should carry out the following checks h Check top surface elements 1 Glow...

Page 18: ...ou will need it if service is ever required Model number ____________________________________________________________________________________ Serial number ____________________________________________...

Page 19: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 20: ...king Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20700 EN 10070...

Reviews: