background image

Viking Installation Guide

Designer Built-In

Electric Cooktops

Summary of Contents for Designer DETU200

Page 1: ...Viking Installation Guide Designer Built In Electric Cooktops...

Page 2: ...__________________9 Clearance Dimensions Wood Composite or Steel Overlay ______________________________11 Electrical Requirements _____________________________________________________________12 Genera...

Page 3: ...ational Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Rd Cleveland OH 44131 5575 Installers should leave these instructions w...

Page 4: ...n This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle DO NOT cut or remove the grou...

Page 5: ...G It is the customer s responsibility to contact a qualified electrical installer To assure that the electrical installation is Adequate and in conformity with national electrical code ANSI NFPA 70 la...

Page 6: ...Dimensions 6 21 53 3 cm 30 3 4 78 1 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 28 71 1 cm 18 9 16 47 2 cm 12 30 5 cm 3 1 4 8 3 cm Power conduit 30 Electric Cooktop Note Dimension includes screw head...

Page 7: ...Dimensions 7 21 53 3 cm 3 1 8 7 9 cm 4 1 4 10 8 cm 36 3 4 93 4 cm 33 3 8 84 7 cm 18 9 16 47 2 cm 3 1 4 8 3 cm Power conduit 12 30 5 cm 36 Electric Cooktop Note Dimension includes screw head...

Page 8: ...uld be fused separately 3 wire 240 208 120VAC 60Hz 60 amp connection Unit is equipped with No 10 ground wire in conduit Should be fused separately Maximum amp usage 240V 35 0 amps 8 4 kw 208V 30 3 amp...

Page 9: ...9 16 87 2 cm max B 19 1 4 49 0 cm min to 19 5 8 49 8 cm max Cutout Dimensions Note Refer to the downdraft installation instructions Downdraft Dimensions DETU200 w DIPR100 DETU260 w DIPR160 A 28 3 4 73...

Page 10: ...e vertical surfaces above 36 91 4 cm the maximum wall cabinet depth must be 13 33 0 cm and wall cabinets within this 6 15 2 cm side clearance must be 18 45 7 cm above the 36 91 4 cm high countertop Wa...

Page 11: ...1 4 cm Wall Installation Island Installation Clearance Dimensions Wood Composite or Steel Overlay The bottom of a standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This wou...

Page 12: ...ation Batter march Park Quincy Massachusetts 02269 A three wire single phase 240 Volt 60 cycle electrical system properly circuit protected to meet Local Codes of NFPA No 70 must be provided Unit must...

Page 13: ...nch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire gray or white colored wire proceed as follows 1 If local codes permit connect the...

Page 14: ...s All wall coverings countertop and cabinets around the cooktop should withstand heat up to 200 F 90 C Keep appliance free from combustible materials gasoline and other flammable vapors Installation P...

Page 15: ...ds beyond the outermost flange of the cooktop All corners should be covered with tape IMPORTANT 1 2 Optional Gasket Turn the cooktop upside down and place on the packaged foam top Note Make sure there...

Page 16: ...to the corresponding leads in the junction box Electrical Connection Final Installation 3 wire 1a Neutral Green Black Red Connect the red and black leads from the unit conduit to the corresponding le...

Page 17: ...to remove these film residues and any installation dust or debris before being used for food preparation A qualified installer should carry out the following checks h Check top surface elements 1 Glow...

Page 18: ...ou will need it if service is ever required Model number ____________________________________________________________________________________ Serial number ____________________________________________...

Page 19: ...________________________________________________________________________________________________________ _______________________________________________________________________________________________...

Page 20: ...king Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20700 EN 10070...