© 2010 Viking Preferred Service
60
Smoke Eliminator
To access smoke eliminator:
1.
Open oven door.
2.
Remove broil element
(see Broil Element
Disassembly, page 57).
3.
Remove screws securing broil baffle and
remove baffle.
4.
Remove screws securing smoke eliminator to
oven cavity.
5.
Repair or replace smoke eliminator.
6.
Reverse procedure to reinstall.
Rack Support
To access rack support:
1.
Remove oven door
(see Door Removal,
page
54).
2.
Remove screws and rack supports from each
side of oven cavity.
3.
Reverse procedure to reinstall.
Service Diagnostics and Procedures–Disassembly
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit before servicing.
Wires removed during disassembly must be replaced on proper terminals to insure correct earth ground and
polarization. After servicing, reconnect electrical power.
Smoke Eliminator
Screw
Screw
Broil Baffle
Screw
Screw
Screw
Screw
Rack Support