PRODUCT MANUAL
Designed, Manufactured and Supported in the USA
C O M M U N I C A T I O N & S E C U R I T Y S O L U T I O N S
VIKING
Features
Applications
Information: 715-386-8861
www.vikingelectronics.com
CL Series
Wireless Analog / Digital
Clocks and Accessories
August 23, 2017
Specifications
Viking’s Wireless Clock System provides reliable, accurately synchronized clocks for your entire facility. Eliminating dedicated clock wiring can save you thousands of dollars on installation
and also allows for easy retrofitting of an existing installation. While most wireless systems are limited to the range of the transmitter, Viking’s system is not. Each clock acts as a Repeater
(transceiver), meaning the secondary clocks both receive and retransmit the signal, maximizing signal transmission distances. The system is comprised of a
CTG-2A
master clock, a
CL-
RFT
clock RF transmitter and Analog or Digital wireless slave clocks. Working on Viking’s 915-928MHz frequency hopping technology eliminates interference with other wireless products
and requires no FCC license, eliminating extraneous fees. The received signal remains strong even under the effects of noise, obstructions or long distances which tend to decrease the
signal to noise ratio. Installation is a cinch for our wireless clocks, just insert the batteries or connect power and hang them. That’s it.
Viking’s
CL Series
wireless clocks include automatic calibration, as well as diagnostics
that allow the user to view the signal strength, how long since the last time the clock
received a signal, a comprehensive analysis of the clock itself and remaining battery
life. The 12 and 16 inch wireless Analog clocks receive and retransmit an RF clock
sync signal every 4 hours (standard mode) or 12 hours (economy mode) allowing for
a battery life of 5 years or 8 years respectively. The 2.5 and 4 inch digital clocks are
powered by an included power adapter and receive and retransmit an RF clock sync
signal every minute. Viking also offers a complete line of accessories for the Analog or
Digital clocks such as: double mount housings, wire guards and surface mount housings
(for digital clocks only).
CTG-2A
Master Clock/Tone
Generator
(DOD# 464)
CL-RFT
Clock RF
Transmitter/
Repeater
CL-A12
12” Analog Clock
(surface mount
hardware included)
CL-A16
16” Analog Clock
(surface
mount hardware included)
CL-D2
Digital Clock with 2.5”
Numbers
(surface or
double mount housing
not included)
CL-D4
Digital Clock with 4”
Numbers
(surface or double
mount housing not included)
CL-DMA12/16
Double Mount Housing for
12”/16” Analog Clocks
(clocks not included)
CL-SMD2/4
Surface Mount
Housing for 2.5”/4”
Digital Clocks
(clock not included)
CL-WGA12/16
Wire Guard for
12”/16” Analog Clocks
CL-WGD4
Wire Guard for 2.5” or 4”
Digital Clocks
CL-DMD2/4
Double Mount
Housing for 2.5”/4”
Digital Clocks
(clocks not included)
CTG-2A Master Clock/ Tone Generator:
• See the complete
CTG-2A
Product Manual,
DOD# 464
CL-RFT Clock RF Data Transmitter/Repeater:
• Transmits the
CTG-2A
RS485 clock sync data wirelessly to the CL Series
wireless clocks
• Can be configured as a wireless repeater to extend RF transmit range
• Powerful transmission range: Up to 6500 ft in open space
• Compact, slim design makes it versatile for mounting
• Can wirelessly receive and transmit data
• LEDs for indication of transmission and/or receipt of RS485 signal
• Powerful 1 watt (30dBm) transmission
• Works with Viking’s 915 - 928 MHz frequency-hopping technology
• FCC Part 14 compliance (no license required)
CL-D2 and CL-D4 Digital Clocks:
• Built-in repeater receives and retransmits clock sync signal each minute
up to 500 ft in open space
• 915 – 928 MHz frequency-hopping technology
• Internal antenna
• Built-in diagnostic mode for easy maintenance
• Receives the RF Sync signal once a minute
• Immediate correction for time change
• 12 or 24 hour format
• Two (2) levels of adjustable brightness
• Loss of communication alert
• Available in red 2.5″ and 4″ displays
• Surface and double mount housing sold separately
• Optional wire guards (see
CL-WGD4
on page 11)
For complete specifications, see pages 3 - 11.
Using the CTG-2A, CL-RFT and CL Series Clocks:
• Wirelessly synchronize all clocks in your facility to the Atomic clock
• Signal the beginning and end of class periods, breaks and lunch periods
for schools
• Signal the beginning and end of shifts, breaks and lunch periods for
factories/businesses
• Provide trigger controlled emergency alert messages for fire, flood, severe
weather, lock down, etc.
• Provide messages at specific times for store sales, promotions, closing
times, airport loading zones, etc.
• Provide Auxiliary contact activation at specific times for specific durations
for controlling lights, cameras, unlocking doors/gates, etc.
CL-A12 and CL-16 Analog Clocks:
• Built-in repeater receives and retransmits clock sync signal up to 500 ft in
open space
• 915 – 928 MHz frequency-hopping technology
• Internal antenna
• Built-in diagnostic mode for easy maintenance
• 5 yr battery life (standard mode) or 8 yr battery life (economy mode),
(2) “D” cell batteries not included
• Black ABS case and polycarbonate crystal
• Optional double mount housing available (see
CL-DMA12/16