Viking 06932B Technical Data Manual Download Page 10

REGULATORY AND HEALTH 

WARNINGS

BULLETIN

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058

Telephone: 269-945-9501  Technical Services: 877-384-5464  Fax: 269-818-1680  Email: [email protected]

Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com

Page 1 of 1

Form No. F_111218    18.11.15     Rev 18.1

New Bulletin

1.  DESCRIPTION

Regulatory and Health Warnings applying to materials used in the manufacture and construction of fire protection products are 

provided herin as they relate to legally mandated jurisdictional regions.

 

WARNING

STATE OF CALIFORNIA, USA

Installing or servicing fire protection products such as sprinklers, valves, piping etc. can expose you to chemicals including, but not li-

mited to, lead, nickel, butadiene, titaninum dioxide, chromium, carbon black, and acrylonitrile which are known to the State of California 

to cause cancer or birth defects or other reproductive harm. 
For more information, go to 

www.P65Warnings.ca.gov

2.  WARRANTY TERMS AND CONDITIONS

For details of warranty, refer to Viking’s current list price schedule at 

www.vikinggroupinc.com 

or contact Viking directly.

Summary of Contents for 06932B

Page 1: ...Casting Brass UNS C84400 Deflector Brass UNS C26000 Bushing Brass UNS C36000 Bulb Glass nominal 3 mm diameter Belleville Spring Sealing Assembly Nickel Alloy coated on both sides with PTFE Tape Screw...

Page 2: ...s the heat sensitive liquid in the glass bulb expands causing the glass to shatter releasing the pip cap and sealing spring assembly Water flowing through the sprinkler orifice strikes the sprinkler d...

Page 3: ...Polyester and Black PTFE Footnotes 1 The sprinkler temperature rating is stamped on the deflector 2 Based on NFPA 13 Other limits may apply depending on fire loading sprinkler location and other requi...

Page 4: ...te Polyester4 and Black Polyester4 2 Brass and Chrome Footnotes 1 Base part number shown For complete part number refer to Viking s current price schedule 2 Metric K factor measurement shown is when p...

Page 5: ...igure 4 Sprinkler Dimensions with the Model E 1 and E 2 Recessed Escutcheons Figure 3 Sprinkler Dimensions with a Standard Escutcheon 1 2 10 mm NPT 2 1 4 57 mm Installed with a standard 1 8 surface mo...

Page 6: ...tall sprinklers onto piping at the floor level Install sprinklers after the piping is in place to prevent mechanical damage DO NOT allow impacts such as hammer blows directly to sprinklers or to fitti...

Page 7: ...CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE Figure 1 Sprinkler shield being removed from a pendent sprinkler Figure 2 Sprinkler cap being removed from a pendent sprinkle...

Page 8: ...these sprinklers NOTE The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed Do not over tighten the sprinkle...

Page 9: ...the corrosion resistant properties of the sprinkler Use care when locating sprinklers near fixtures that can generate heat Do not install sprinklers where they would be exposed to temperatures exceed...

Page 10: ...tion of fire protection products are provided herin as they relate to legally mandated jurisdictional regions WARNING STATE OF CALIFORNIA USA Installing or servicing fire protection products such as s...

Reviews: