4
DO NOT touch any wire during operation as high voltage might be causing
electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to
rain or moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced
if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing
or attempt any repairs yourself. In the unlikely event your unit may require
service, please contact your nearest dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that
the unit is firmly fixed to avoid vibration and slipping while operating.
And make sure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Also always use a
safety cable that can hold 12 times of the weight of the unit when installing the
fixture.
The equipment must be fixed by professionals. And it must be fixed at a place
where is out of the touch of people.
49
7. Trouble shooting
Following are a few common problems that may occur during operation. Here are
some suggestions for easy troubleshooting:
A. The unit does not work, no light and the fan does not work
1. Check the connection of power and main fuse.
2. Measure the mains voltage on the main connector.
3. Check the power on LED.
B. Not responding to DMX controller
1. DMX LED should be on. If not, check DMX connectors, cables to see if link
properly.
2. If the DMX LED is on and no response to the channel, check the address
settings and DMX polarity.
3. If you have intermittent DMX signal problems, check the pins on connectors or on
PCB of the unit or the previous one.
4. Try to use another DMX controller.
5. Check if the DMX cables run near or run alongside to high voltage cables that
may cause damage or interference to DMX interface circuit.
C. One of the channels is not working well
1. The stepper motor might be damaged or the cable connected to the PCB is
broken.
2. The motor’s drive IC on the PCB might be out of condition.