background image

Channel mode

Channel 

Function 

       Value 

      Percent

1

 

        Master Dimmer

         

RGB and RGB mix

Strobe speed 0.5 to 25 times / sec

0 -255                            0-100

0 -255                            0-100

0 -255                            0-100

Channel mode

Channel 

Function 

Value 

Percent

1

 

Master Dimmer 

0-255 

0-100

red 

0-255 

0-100

3

 

green 

0-255 

0-100

blue

 

0-255 

0-100

5              

Strobe speed 0.5 to 25 times / sec 

0-255 

0-100

0-255 

0-100

Strobe frequency

 

15-255 

0-100

Marcos

 

0-255 

0-255

Marcos speed

 

0-255 

0-100

17 

Channel mode

Channel 

Function 

Value 

Percent

   

Master Dimmer

   

0-255 

0-100

Seg 1 and seg 2  Red

 

0-255 

0-100

Seg 1 and seg 2  Green

 

0-255 

0-100

Seg 1 and seg 2  Blue

 

0-255 

0-100

Seg 3 and seg 4  Red

 

0-255 

0-100

Seg 3 and seg 4  Green

 

0-255 

0-100

Seg 3 and seg 4  Blue

 

0-255 

0-100

Seg 5 and seg 6  Red

 

0-255 

0-100

Seg 5 and seg 6  Green

 

0-255 

0-100

10 

Seg 5 and seg 6  Blue

 

0-255 

0-100

11 

Seg 7 and seg 8  Red

 

0-255 

0-100

12 

Seg 7 and seg 8  Green

 

0-255 

0-100

13 

Seg 7 and seg 8  Blue

14               

Strobe speed 0.5 to 25 times / sec                   

0-255 

0-100

0-255 

0-100

15 

Strobe frequency

 

15-255 

0-100

16 

Marcos

 

0-255 

0-255

17 

Marcos speed

 

0-255 

0-100

DMX Protocol

 RGB version

Summary of Contents for VK ST8be LED STROBE

Page 1: ...1 with quicklock design VK ST8be LED STROBE USER MANUAL Rev 2 02 RGB White Versions...

Page 2: ...sy use and standalone use The unit can be set to run from DMX or used as a stand alone strobe with operational values set on the LCD rear display Power is via Powercon in and out and DMX is available...

Page 3: ...r or covered use only Do not stare directly into the light Never attempt to bypass the fuse Always replace defective fuses with ones of the specified type and rating Verify that the power feed cable i...

Page 4: ...ire to neutral Connect the green yellow wire to ground earth The device must be grounded earthed and be able to be isolated from AC power The AC power supply must incorporate a fuse or circuit breaker...

Page 5: ...Terminator Do not overload the link Up to 32 devices may be connected on a serial link Terminate the link by installing a termination plug in the output socket of the last fixture The termination plu...

Page 6: ...Menu chart Main Menu Function Function DMX Mode Function Show Mode Function DMX Address Function Channel Mode Function Manual Function System Function DMX Address A 001 Channel Mode 02 Channels Functi...

Page 7: ...hannel Function Value Percent 1 Master Dimmer 0 255 0 100 2 Seg 1 and seg 2 Red 0 255 0 100 3 Seg 1 and seg 2 Green 0 255 0 100 4 Seg 1 and seg 2 Blue 0 255 0 100 5 Seg 3 and seg 4 Red 0 255 0 100 6 S...

Page 8: ...e version Channel Function Value Percent 1 Master Dimmer 0 255 0 100 2 Segment 1 Red 0 255 0 100 3 Segment 1 Green 0 255 0 100 4 Segment 1 Blue 0 255 0 100 5 Segment 2 Red 0 255 0 100 6 Segment 2 Gree...

Page 9: ...00 8 Marco speed 0 255 0 100 Channel Function Value Percent 1 Segment 1 dimmer 0 255 0 100 2 Segment 2 dimmer 0 255 0 100 3 Segment 3 dimmer 0 255 0 100 4 Segment 4 dimmer 0 255 0 100 5 Segment 5 dimm...

Reviews: