11
WOOD/COMPOSITE OVERLAY INSTALLATION
The bottom of a standard hood should 30” (76.2 cm) min to 36” (91.4 cm) max above the ceramic glass surface. This
would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. Refer to the
rangehood installation instructions for additional information. These dimensions provide for safe and efficient
operation of the hood.
66” - 72”
(167.6 cm -
182.9 cm)
66” - 72”
(167.6 cm -
182.9 cm)
36”
(91.4 cm)
ISLAND INSTALLATION
WALL INSTALLATION
36”
(91.4 cm)
Metal Hood
Metal Hood
Wood/Composite Overlay
30” (76.2 cm) min
36” (91.4 cm) max
30” (76.2 cm) min
36” (91.4 cm) max
10
ELECTRICAL CONNECTION
Use a 3-wire power supply cord kit rated for 60 amps -
125/250 volts with closed loop terminals and marked for use
with ranges. Where local codes do not permit grounding
through neutral, use a 4-wire power supply cord. the cord or
conduit must be secured to the range with the strain relief
bracket. The electrical connection is made at the terminal
block, which is located behind the access door on the back of
the range.
3-Wire Power Supply Cord
1. Remove access door.
2. Remove supply cord strain relief bracket and 3-supply cord
mounting screws on the terminal block.
3. Feed supply cord up thru the hole in the bottom of the
range back.
4. Attach the line #1 (red) and line #2 (black) leads to the
outside terminal and the neutral wire (white) to the center
terminal on the terminal block.
5. Reattach supply cord strain relief bracket over supply cord,
pushing supply cord up toward terminal block to relieve
strain before tightening.
6. Reattach access door.
4-Wire Power Supply Cord
1. Remove access door.
2. Remove supply cord strain relief bracket and 3-supply cord
mounting screws on the terminal block.
3. Remove grounding screw; cut-off and discard ground strap.
4. Feed supply cord up thru the hole in the bottom of the
range back.
5. Attach the ground lead (green) with the ground screw that
was removed in step #3.
6. Attach the line #1 (red) and line #2 (black) leads to the
outside terminal and the neutral wire (white) to the center
terminal on the terminal block.
7. Reattach supply cord strain relief bracket over supply cord,
pushing supply cord up toward terminal block to relieve
strain before tightening.
8. Reattach access door.
Countertop
Countertop
Wood/Composite Overlay