background image

7

WATER SUPPLY REQUIREMENTS

E

ELLE

EC

CT

TR

RIIC

CA

ALL  S

SH

HO

OC

CK

K  H

HA

AZ

ZA

AR

RD

D

S

So

om

me

e  w

waatte

err  m

maayy  rre

em

maaiin

n  iin

n  lliin

ne

e..    E

Elle

eccttrriicc

d

drriillll  m

mu

usstt  b

be

e  g

grro

ou

un

nd

de

ed

d  tto

o  p

prre

evve

en

ntt  sse

evve

erre

e  o

orr

lle

etth

haall  ssh

ho

occkk  iiff  w

waatte

err  iiss  iin

n  lliin

ne

e  aan

nd

d  e

en

ntte

errss  d

drriillll

d

du

urriin

ng

g  u

usse

e..

U

Usse

e  o

on

nllyy  1

1//4

4””  ((6

6  m

mm

m))  cco

op

pp

pe

err  ttu

ub

biin

ng

g  ffo

orr  w

waatte

err  lliin

ne

e..    D

Do

o

N

No

ott  iin

nssttaallll  cco

op

pp

pe

err  ttu

ub

biin

ng

g  iin

n  aarre

eaa  w

wh

he

erre

e  tte

em

mp

pe

erraattu

urre

ess

d

drro

op

p  b

be

ello

ow

w  3

35

5

o

o

F

F  ((1

1..7

7

o

o

C

C))..    B

Be

effo

orre

e  aattttaacch

hiin

ng

g  cco

op

pp

pe

err  ttu

ub

biin

ng

g

tto

o  rre

effrriig

ge

erraatto

orr,,  ffllu

ussh

h  aatt  lle

eaasstt  2

2  q

qu

uaarrttss  ((1

1..9

9  LL))  o

off  w

waatte

err

tth

hrro

ou

ug

gh

h  tth

he

e  cco

op

pp

pe

err  ttu

ub

biin

ng

g  aan

nd

d  iin

ntto

o  aa  b

bu

ucckke

ett  tto

o  rre

em

mo

ovve

e

aan

nyy  p

paarrttiicclle

ess  iin

n  tth

he

e  w

waatte

err  lliin

ne

e..

••V

Viikkiin

ng

g  R

Raan

ng

ge

e  C

Co

orrp

po

orraattiio

on

n  iiss  n

no

ott  rre

essp

po

on

nssiib

blle

e  ffo

orr  p

prro

op

pe

errttyy  d

daam

maag

ge

e  d

du

ue

e  tto

o  iim

mp

prro

op

pe

err  iin

nssttaallllaattiio

on

n  o

orr  w

waatte

err  cco

on

nn

ne

eccttiio

on

n..

•Connect 1/4” (6mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances.
•Length of copper tubing must reach from water supply connection to refrigerator connection with an additional length

to facilitate moving the refrigerator out of enclosure for cleaning or service.  Tubing should be soft instead of rigid and
ends should be free of burrs.

•Copper tubing route must be above 35oF (1.7oC) to prevent water line from freezing.
••D

Do

o  n

no

ott  u

usse

e  p

pllaassttiicc  w

waatte

err  lliin

ne

ess..

••D

Do

o  n

no

ott  u

usse

e  tth

he

e  sse

ellff--p

piie

errcciin

ng

g  ffe

eaattu

urre

e  o

off  aa  ssaad

dd

dlle

e  vvaallvve

e..    The hole made by the piercing lance is too small for the water

flow rate required by the ice maker.  To use a saddle valve, follow the instructions below located under “To rough in
water line” on how to pre-drill a 3/16” (4.5 mm) diameter hole.

•If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and

refrigerator.  Do not locate shut-off valve behind refrigerator.

•The installation of Viking refrigerators with an reverse osmosis system is acceptable aass  llo

on

ng

g  aass  tth

he

e  w

waatte

err  p

prre

essssu

urre

e

rre

em

maaiin

nss  w

wiitth

hiin

n  tth

he

e  aallllo

ow

waab

blle

e  P

PS

SII  aass  ssttaatte

ed

d  b

be

ello

ow

w.. It is important to note that with many reverse osmosis systems, the

pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops.  This must
be considered when checking the water pressure coming into the unit.

•Connect a vertical or horizontal 1/2” (1.2 cm) to 1 1/4” (3.2 cm) COLD water line near refrigerator area.
•Run water line through the floor, back, or side wall. Tubing should lay flat on floor underneath refrigertor.  Clamp

tubing to wall or floor.

•Water pressure must be greater than 20 psi and less than 120 psi.

To rough in water line:

1.

Turn OFF main water supply.  Turn ON nearest faucet long enough to clear line of water.

2.

V

V

ertical cold water line: 

Use grounded electric drill or hand drill to drill 3/16” (4.5 mm) hole

in an easily accessible location in water line.  

Horizontal cold water line: 

Use grounded electric drill or hand drill to drill 3/16” (4.5 mm)

hole in the TOP of the water line.  This will keep sediment from collecting in valve.

3.   Position washer over hole in water line.    Turn saddle valve handle clockwise to expose

piercing lance a maximum of 3/16” (4.5 mm).  Align piercing lance over hole in water line.
Place both halves of saddle valve bracket against water line.  Turn saddle valve handle
clockwise until piercing lance enters hole in water line and is firmly seated.  The saddle valve
is now in the closed position.  Tighten packing nut.  Evenly and firmly tighten bracket screws
so washer will make a water-tight connection.  

Do not overtighten screws: copper tubing

could be crushed.

4.   Check that both ends of copper tubing are cut square.  Slide compression nut and sleeve onto copper tubing.

Insert end of copper tubing completely into valve outlet.  Tighten compression nut to outlet with adjustable
wrench.  

Do not overtighten.  

5.  Turn on main water supply.  Check for leaks.  Turn saddle valve handle counterclockwise and run 2 (1.9 L) quarts of

water through copper tubing and into a bucket.  Turn saddle valve clockwise to shut off water to copper tubing.

6.   Route copper tubing to All Freezer area.
7.   Leave an additional length of copper tubing coil to facilitate moving the All Freezer out of enclosure for cleaning

or service. 

8.   See page 37 for water connection instructions.

WARNING

Summary of Contents for DDBB363

Page 1: ...allation specifications and dimensions properly install unit remove any moldings or decorative panels that prevent the unit from being serviced make sure that you have these materials not provided wit...

Page 2: ...er 5 1 cu ft 14 cu meters Total Capacity 20 3 cu ft 57 cu meters Approximate Shipping Weight 500 lbs 227 3 kg BASIC SPECIFICATIONS AND DIMENSIONS DESIGNER MODELS D DE ES SC CR RI IP PT TI IO ON N D DD...

Page 3: ...Amp Usage 9 9 amps Inlet Water 1 4 copper tubing inlet waterline Requirements minimum 20 psi maximum 120 psi Overall Interior Dimensions Refrigerator 15 2 cu ft 43 cu meters Freezer 5 1 cu ft 14 cu m...

Page 4: ...ATOR 1 Electronic Controls 2 Spillproof Shelves 5 3 Moisture Control Produce Drawers 2 4 Meat SavorTM Produce Drawer 1 5 Ice Bucket 1 6 Dairy Compartments 2 7 Door Bins 5 8 Wire Freezer Baskets 2 7 7...

Page 5: ...2 2 9 90 0 2 2 c cm m 2 29 9 7 73 3 7 7 c cm m 7 73 3 3 3 8 8 1 18 86 6 4 4 c cm m 8 82 2 7 7 8 8 2 21 10 0 5 5 c cm m m mi in n a an nt ti i t ti ip p b bo oa ar rd d a an nd d o op pe en ni in ng g...

Page 6: ...m deep cabinet openings They can be installed in standard 24 61 0 cm deep openings The door faces and top grille will protrude 3 4 1 9 cm into the room 1 1 1 1 2 2 3 3 8 8 c cm m 7 73 3 3 3 8 8 1 18 8...

Page 7: ...le valve is not used place a separate shut off valve in an easily accessible location between water supply and refrigerator Do not locate shut off valve behind refrigerator The installation of Viking...

Page 8: ...ance is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle Do not use an...

Page 9: ...n n no ot t c co om mp pl le et te el ly y i in ns st ta al ll le ed d K Ke ee ep p d do oo or rs s c cl lo os se ed d u un nt ti il l a ap pp pl li ia an nc ce e i is s c co om mp pl le et te el ly y...

Page 10: ...10 DOOR SWING CONSIDERATIONS DESIGNER MODEL FULL OVERLAY MODEL...

Page 11: ...11 TIPPING CONSIDERATIONS PROFESSIONAL MODELS DESIGNER AND FULL OVERLAY MODELS 82 5 8 209 9 cm 86 1 16 218 6 cm...

Page 12: ...OVERALL DIMENSIONS PROFESSIONAL MODEL S S S S S S 35 1 2 90 2 cm 22 3 16 56 4 cm 24 3 4 62 9 cm 5 16 0 8 cm 9 32 0 7 cm 11 32 0 9 cm D DO OO OR R Side Trim T TO OP P 35 1 2 90 2 cm 35 88 9 cm S SI ID...

Page 13: ...PROFESSIONAL MODELS Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional 2 1 2...

Page 14: ...14 CABINET INFORMATION PROFESSIONAL MODELS Cont d...

Page 15: ...15 CUSTOM SIDE PANEL DIMENSIONS PROFESSIONAL MODELS FOR 3 4 1 9 cm SIDE PANELS...

Page 16: ...16 BOTTOM MOUNT REFRIGERATOR OVERALL DIMENSIONS DESIGNER MODELS T TO OP P S SI ID DE E 36 91 5 cm D DO OO OR R F FR RO ON NT T 36 91 5 cm 35 88 9 cm...

Page 17: ...17 CABINET AND PANEL INFORMATION DESIGNER MODELS Designer models fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 5 1 cm curved handle depth...

Page 18: ...ODELS Full overlay models with 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 63 5 cm deep countertop depth cabinet openings with no protrusion into room except custom han...

Page 19: ...MATION FULL OVERLAY MODELS Full overlay models with 3 4 1 9 cm thick panels and custom handles locally supplied fit flush in 25 63 5 cm deep countertop depth cabinet openings with no protrusion into r...

Page 20: ...RLAY MODELS Cont d Full overlay models can be installed in standard 24 61 0 cm deep openings However the door faces and top ventilation grille will protrude 3 4 1 9 cm into the room This is ideal for...

Page 21: ...21 CUSTOM PANEL DIMENSIONS...

Page 22: ...ns to the right Notch for left hinge door Figure A Front side of 3 4 1 9 cm panel 7 8 2 2 cm 5 8 1 6 cm B Ba ac ck ks si id de e o of f 3 3 4 4 1 1 9 9 c cm m p pa an ne el l w wi it th ho ou ut t t t...

Page 23: ...ap to door trim and Z brackets 5 Install handle side door trim with screws Install door trim inserts supplied on all four sides of door by starting in one corner and pushing the strip in place 6 Insta...

Page 24: ...24 Z BRACKET INSTALLATION...

Page 25: ...t th he e p pr ro od du uc ct t f fo or r e ea ac ch h s si id de e p pa an ne el l u us se ed d N NO OT TE E R Re eq qu ui ir re es s s si id de e p pa an ne el l h ha ar rd dw wa ar re e k ki it t...

Page 26: ...lication see template in Custom Air Grille Panel Dimensions on pages 31 32 Right hinge application Item Qty Description Size A 2 End 3 x 3 3 4 x 3 4 B 2 Top Bottom See page 28 C 2 Insert End 1 1 2 x 2...

Page 27: ...NAL CUSTOM AIR GRILLE DUCT LIP EDGE LOCATIONS F FR RO ON NT T V VI IE EW W 35 1 2 90 2 cm 34 86 4 cm 3 4 1 9 cm TYP 1 1 2 3 8 cm 3 7 6 cm 3 3 4 9 5 cm TOP OF CUSTOM AIR GRILLE Bracket Custom Air Grill...

Page 28: ...cm 3 8 0 95 cm 1 2 1 3 cm 3 4 1 9 cm 3 3 4 9 5 cm TOP VIEW RIGHT VIEW LEFT FRONT VIEW 1 2 1 3 cm 3 4 1 9 cm 3 3 4 9 5 cm 1 8 0 3 cm 3 7 6 cm Bottom View R1 4 Route a 1 2 1 3cm wide by 1 2 1 3 cm deep...

Page 29: ...29 HINGE COVER DIMENSIONS 1 2 1 3 cm 3 1 8 7 9 cm 1 4 0 6 cm 26o 23 32 1 8 cm Hinge cover protrudes 9 32 0 7 cm beyond wood grille 35 1 2 90 2 cm INSERT DIMENSIONS TOP VIEW FRONT VIEW Right View...

Page 30: ...unit from skid Use excess packaging to protect decorative trim Verify that leveling legs are up 0 adjustment see Figure 5 6 To avoid floor damage use protective material see Figure 6 U Us se e t tw wo...

Page 31: ...0 cm beyond rear ledge attach 1 2x4 to wall Item B attach 1 2x4 to rear ledge of cabinet Item C and attach L bracket assembly to 2x4 mounted on wall Item A E El le ec ct tr ri ic ca al l S Sh ho oc ck...

Page 32: ...unit side N NO OT TE E W Wh he en n m mo ov vi in ng g t th he e u un ni it t i in nt to o p po os si it ti io on n b be e c ca ar re ef fu ul l n no ot t t to o c cr ri im mp p k ki in nk k o or r c...

Page 33: ...the water level of the reverse osmosis storage area drops This must be considered when checking the water pressure coming into the unit The 1 4 brass compression union is located in the literature pac...

Page 34: ...with an 8 20 3 cm long magnetic 1 4 6 cm nut driver Pull assembly forward 3 Open refrigerator door so door stop arm and shoulder screw are accessible Shoulder screws should be in 110o door opening pos...

Page 35: ...is appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle DO NOT CUT OR REMOVE...

Page 36: ...VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 Specifications subject to change without notice F20353 PS0705VR...

Reviews: