Clearance Dimensions
9
Note:
Door handle of oven should be 36”
(91.4 cm) above the floor.
Note:
The grounded electrical socket should
be placed above or below cutout(s).
CAUTION
Burn hazard.
To avoid risk of personal injury;
the use of cabinets for storage
above the appliance may result
in a potential burn hazard. Combustible
items may ignite, metallic items may
become hot and cause burns.
CAUTION
To prevent possible damage to cabinets
and cabinet finishes, use only moisture
resistant materials and finishes that will
withstand temperature up to 190°F
(88°C). When cabinets are covered with
laminates, an appropriate heat-resistant
adhesive must be used. Consult your
manufacturer for proper specifications.
Electrical Requirements
Check your national and local codes
regarding this unit. These ovens require
3-wire, 120 VAC/60 Hz.
See “Connecting
Gas & Electrical” section for grounding
instructions.
Gas Connection
The gas supply (service) line must be the
same size or greater than the inlet line of the
appliance. This oven uses a 1/2” (1.3 cm) ID
NPT (Sch40) inlet. Sealant on all pipe joints
must be resistive to LP gas.
These ovens are designed specifically for
natural gas or liquid propane (LP) gas. It is
shipped from the factory adjusted for use
with natural or propane (LP) gas. Before
beginning installation verify that the
model is compatible with the intended
gas supply.
Manual shut-off valve:
This installer-supplied valve must be installed
in the gas service line before the appliance
in the gas stream and in a location where it
can be reached quickly in the event of
an emergency.
In Massachusetts:
A “T” handle type
manual valve must be installed in the gas
supply line to the appliance.
IMPORTANT: Any conversion required
must be performed by your dealer or a
qualified licensed plumber or gas service
company
. Please provide the service person
with this manual before work begins.
WARNING
Electrical shock hazard.
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned
off at the breaker box and gas supply is
turned off until the oven is installed and
ready to operate, installation by an
authorized installer only.
Electrical & Gas Requirements
Cutout Dimensions
8
24”
(61.0 cm) min.
1-1/2”
(3.8 cm)
3”
(7.6 cm) dia.
14-1/4”
(36.2 c
m)
30-5/8”
(77.8 cm)
Electrical outlet to be located
in shaded area on rear wall
Gas inlet
location
3”
(7.6 cm)
28-5/8”
(72.7 cm)
21-5/16”
(54.1 cm)
17”
(43.2 cm) min.
30”
(76.2 cm)
Recommended
30”W. Cutout