47
46
Page 1: ...111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com F21339 EN 123113 Installation Guide All Refrigerator All Freezer ...
Page 2: ... Tip Dimensions 36 _______________________________________________________ 13 Dimensions Specifications Dual 30 Dual 30 36 ____________________________ 14 Dimensions Specifications Dual 30 Dual 30 36 with flush mount trim _________18 Cutout Dimensions Dual 30 ____________________________________________________ 22 Anti Tip Dimensions Dual 30 ___________________________________________________ 23 C...
Page 3: ...urn power disconnect switch to OFF position before removing top grille Failure to do so can result in death or electrical shock W A R N I N G TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or more people to move and install appliance Failure to do so can...
Page 4: ...it 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 1 amps 5 7 amps Inlet water requirements 1 4 copper tubing inlet waterline minimum 20 psi N A maximum 120 psi Overall interior dimensions Total capacity 15 9 cu ft 450 liters 18 4 cu ft 522 liters Approximate shipping weight 550 lbs 247 5 kg 525 lbs 236 3 kg 36 All Refrigerator All Freezer Description VCFB VCRB Overa...
Page 5: ...wire cord with grounded 3 prong plug attached to product Maximum amp usage 9 1 amps 5 7 amps Inlet water requirements 1 4 copper tubing inlet waterline minimum 20 psi N A maximum 120 psi Overall interior dimensions Total capacity 15 9 cu ft 450 liters 18 4 cu ft 522 liters Approximate shipping weight 550 lbs 247 5 kg 525 lbs 236 3 kg 36 All Refrigerator All Freezer with Flush Mount Trim Descriptio...
Page 6: ...max to bottom of anti tip board 23 58 4 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions 11 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 29 5 8 75 2 cm min to 29 3 4 75 6 cm max 30 76 2 cm Flush Mount only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Shown for All Fr...
Page 7: ...1 1 2 3 8 cm x 3 1 2 8 9 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 3 7 6 cm 29 1 2 74 9 cm 3 1 2 8 9 cm 1 1 2 3 8 cm Anti Tip Dimensions 13 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 35 5 8 90 5 cm min to 35 3 4 90 8 cm max 36 91 4 cm Flush Mount only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Shown for Al...
Page 8: ... 30 30 76 2 cm 76 2 cm 30 76 2 cm 26 1 2 67 3 cm Dimensions 15 24 61 0 cm 1 2 54 cm Between Units 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 22 3 16 56 4 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 29 73 7 cm 29 73 7 cm 30 30 76 2 cm 76 2 cm 30 76 2 cm 30 30 76 2 cm 76 2 cm 30 76 2 cm 26 1 2 67 3 cm Dimensions 14 Dual 30 All Refrigerator All Freezer Dual 30 36 All Refrigerat...
Page 9: ...166 7 cm 71 5 8 181 9 cm Cutout height 82 7 8 210 5 cm min to 84 1 16 213 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 30 Freezer 9 1 amps per unit 30 Refrigerator 5 7 amps per unit 36 Freezer 9 5 amps per unit 36 Refrigerator 6 5 amps per unit Inlet water requirem...
Page 10: ...rim Note Flush Mount Trim is shipped with the refrigerator in a box marked Refrigerator Trim Parts DO NOT DISCARD 24 61 0 cm 1 2 54 cm Between Units 35 88 9 cm 36 36 91 5 cm 91 5 cm 36 91 5 cm 9 5 32 23 3 cm 82 3 4 210 2 cm min to 84 1 16 213 5 cm max 20 3 4 52 7 cm 23 3 8 59 4 cm 29 73 7 cm 75 15 16 192 9 cm 3 19 32 9 1 cm 30 30 76 2 cm 76 2 cm 30 76 2 cm 26 1 2 67 3 cm Dual 30 36 All Refrigerato...
Page 11: ...3 5 cm max Cutout depth 24 61 0 cm min Electrical requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum amp usage 30 Freezer 9 1 amps per unit 30 Refrigerator 5 7 amps per unit 36 Freezer 9 5 amps per unit 36 Refrigerator 6 5 amps per unit Inlet water requirements 1 4 copper tubing inlet waterline minimum 20 psi All Freezer only m...
Page 12: ...58 4 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 23 58 4 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 23 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 59 5 8 151 4 cm 60 152 4 cm Flush Mount only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left R...
Page 13: ... cm x 3 1 2 8 9 cm Flush Mount Anti Tip Location 29 73 7 cm 3 1 2 8 9 cm 3 7 6 cm 23 58 4 cm 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 23 58 4 cm Anti Tip Dimensions 25 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 65 5 8 166 7 cm 66 167 6 cm Flush Mount only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note C...
Page 14: ...3 7 cm 3 1 2 8 9 cm 3 7 6 cm 29 73 7 cm 29 73 7 cm 3 1 2 8 9 cm 1 1 2 3 8 cm 29 73 7 cm Anti Tip Dimensions 27 9 22 9 cm 73 3 8 186 4 cm 82 7 8 210 5 cm min anti tip board opening height 84 1 16 213 5 cm max anti tip board opening height 71 5 8 181 9 cm 72 182 8 cm Flush Mount only 24 61 0 cm Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Re...
Page 15: ... overhang Door Wall 1 13 16 4 6 cm Space if 24 61 0 cm standard cabinet depth is used 3 4 1 9 cm Full end panel 24 61 0 cm Standard cabinet depth 1 3 4 4 4 cm Offset 5 16 0 8 cm Cabinet Information 28 Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 1 3 4 4 4 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the roo...
Page 16: ...61 0 cm Standard cabinet depth 25 63 5 cm countertop depth Wall 3 4 1 9 cm Full end panel Door Wall 1 2 5 cm space if 25 63 5 cm cabinet depth is used 3 4 1 9 cm Full end panel 25 63 5 cm Flush 1 2 5 cm space if 25 63 5 cm cabinet depth is used Flush Cabinet Information With Flush Mount Trim 30 Models with flush mount trim fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion i...
Page 17: ... Mount Trim 33 3 4 1 9 cm End panel 5 32 0 4 cm 3 16 0 5 cm Back filler panel 22 7 16 57 0 cm 22 7 16 57 0 cm 22 1 4 56 5 cm 6 15 2 cm Optional kickplate notch Dimensions determined by cabinets 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 82 7 8 210 5 cm min to 84 1 16 213 5 cm max 6 15 2 cm 22 1 4 56 5 cm Custom Side Panel Dimensions 32 Depending on how high leveling feet are raised and cabinet en...
Page 18: ...rough doorways Floors can support unit s weight plus food weight approximately 1200 pounds 540 kg per unit Floors underneath appliance are level with surrounding finished floor Rear wall is solid and is able to support two horizontally mounted 2 X 4s included bolted to two wall studs The 2 X 4 board bolt heads must be flush with 2 X 4 to prevent obstruction Remove anything attached to rear or side...
Page 19: ...ended 1 4 0 6 cm 4 Remove carton and exterior packaging Save cardboard shipping material to protect floor surface when installing unit Remove anti tip board kickplate and door trim pieces DF models from rear of unit 36 Moving Unit Remove shipping brackets from skid by removing 4 bolts 2 on each side with a 1 2 deep well socket wench and a pair of pliers Note Tilting unit is not required to remove ...
Page 20: ... 3 3 3 10a Plug in power cord to verify operation Note Make sure power switch and showroom switch are in the On Position Place unit within 3 of being flush with cabinets Note To avoid cabinet damage place cardboard between cabinets and unit When moving unit do not crimp kink or crush water supply line 10b 11 Carefully move unit until semi flush with cabinet depending on unit Pull supply tubing for...
Page 21: ...Using a Phillips screwdriver attach the kickplate to the unit and adjust to desired height 14 15 Wall 2 x 4 Refrigerator Screw 16 17 1 2 18 2 3 19 Kickplate Installation 3 1 2 20 1 2 21 110 120 90 Open refrigerator door so door stop and shoulder screw are accessible Note Shoulder screw should be in 110 door opening position Remove shoulder screw and place in 90 or 120 position Door Stop Adjustment...
Page 22: ... tube is properly inserted Verify icemaker bailarm is down Align square door s Verify drain pan is properly installed and there are no leaks in water connection Install kickplate Remove internal packaging and labels and wipe unit down Installer s information Installer s name _____________________________ Installer s company _________________________ Date ________________________________________ 42...
Page 23: ...nt indicator and alarm To exit the Sabbath Mode B Press and hold Activate Controls and then Display Off for 3 seconds The control will beep three times to alert the user the Sabbath Mode has been exited 3 Verify unit is not in Showroom Mode If in Showroom Mode A The Showroom Mode will disable the refrigeration system but all other functions are normal These include lights and control If the refrig...
Page 24: ...47 46 ...