Blue (COM)
Violet (NC)
White (NO)
Camera
Controller
(not included)
OR
Rear View
of the K-1200
Green
Red
** Gel-Filled Butt
Connectors (included)
Black
Black
* Ferrite Core
(included)
K-1200
260878-1
VIKING
Model:
P/N:
S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
DEV:
Q171360
Q171360
100 W 0.5W
100 W 0.5W
CO Line
120V AC
3
Applications
Important:
To operate the
K-1200
during a power failure, a UPS should be installed.
A. Connecting a Doorstrike to the K-1200 Internal Relay
The
K-1200
provides a dry contact output that can be used for operation of a door strike. To use this feature, the
Door Strike Code and Door Strike Time must be set in programming. In this mode, when the Door Strike Code is
detected, the
K-1200
will energize the relay for the period of time selected in the Door Strike Time (see
Programming
section
E, G
and
H
).
If a Postal Lock is required, connect the normally open contacts of the lock to the two white wires coming from the
two pin connector on the lower portion of the control board. When the postal lock is momentarily actuated, the
door strike will energize for the programmed Door Strike Time.
* Note:
To prevent unwanted radio interference, route the connecting wires through the included ferrite core.
** Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire
with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating.
Rear View
of the K-1200
CO Line
Yellow (N.O.)
Brown (COM)
Green
Red
** Gel-Filled Butt Connectors (included)
Black
Black
* Ferrite Core
(included)
White
White
Postal Lock
Switch (N.O.)
Orange (N.C.)
K-1200
260878-1
VIKING
Model:
P/N:
S/N: XXXXXX
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
DEV:
Q171360
Q171360
100 W 0.5W
100 W 0.5W
120V AC
Doorstrike / Magnetic Lock
120V AC
B. Connecting Camera Control to the K-1200 Internal Relay
Another internal relay in the
K-1200
can be used to trigger a camera controller. When the
K-1200
makes a call,
it will energize the relay and hold it on until the call is done.
* Note:
To prevent unwanted radio interference, route the connecting wires through the included ferrite core.
** Note:
The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire
with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating.