Blue (COM)

Violet (NC)

White (NO)

Camera

Controller

(not included)

OR

Rear View
of the K-1200

Green

Red

** Gel-Filled Butt

Connectors (included)

Black

Black

* Ferrite Core

(included)

K-1200 

260878-1

VIKING

Model: 

P/N: 

S/N: XXXXXX

Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016

DEV: 

Q171360

Q171360

100 W  0.5W

100 W  0.5W

CO Line

120V AC

3

Applications

Important:

To operate the

K-1200

during a power failure, a UPS should be installed.

A.  Connecting a Doorstrike to the K-1200 Internal Relay 

The 

K-1200

provides a dry contact output that can be used for operation of a door strike. To use this feature, the

Door Strike Code and Door Strike Time must be set in programming. In this mode, when the Door Strike Code is
detected, the 

K-1200

will energize the relay for the period of time selected in the Door Strike Time (see

Programming

section 

E, G

and 

H

). 

If a Postal Lock is required, connect the normally open contacts of the lock to the two white wires coming from the
two pin connector on the lower portion of the control board. When the postal lock is momentarily actuated, the
door strike will energize for the programmed Door Strike Time.

* Note:

To prevent unwanted radio interference, route the connecting wires through the included ferrite core.

** Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire

with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating.

Rear View
of the K-1200

CO Line

Yellow (N.O.)

Brown (COM)

Green

Red

** Gel-Filled Butt Connectors (included)

Black

Black

* Ferrite Core

(included)

White

White

Postal Lock

Switch (N.O.)

Orange (N.C.)

K-1200 

260878-1

VIKING

Model: 

P/N: 

S/N: XXXXXX

Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016

DEV: 

Q171360

Q171360

100 W  0.5W

100 W  0.5W

120V AC

 Doorstrike / Magnetic Lock

120V AC

B.  Connecting Camera Control to the K-1200 Internal Relay

Another internal relay in the 

K-1200

can be used to trigger a camera controller. When the 

K-1200

makes a call,

it will energize the relay and hold it on until the call is done.

* Note:

To prevent unwanted radio interference, route the connecting wires through the included ferrite core.

** Note:  

The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire

with a maximum insulation of 0.082 inches. Cut off stripped ends prior to terminating.

Summary of Contents for K-1200/EWP

Page 1: ...r speaker Self draining mic mount Faceplate keypad mic and speaker gaskets K 1200 EWP is designed to meet IP66 Ingress Protection Rating see DOD 859 for more info Operates on 12 to 24 volts AC DC 12 speed dial buttons 22 digits each 12 alternate number positions 22 digits each One button operation no call button Hang up on CPC busy silence time out or dial tone Touch tone restriction from micropho...

Page 2: ...crews that mount the directory lens to the front of the K 1200 using the included Allen wrench Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the names with the front panel graphics For your convenience the back of this document has pre printed directory forms Note To print directory forms for the K 1200 go to www vikingelectronics com ...

Page 3: ... door strike will energize for the programmed Door Strike Time Note To prevent unwanted radio interference route the connecting wires through the included ferrite core Note The gel filled water tight butt connectors are designed for insulation displacement on 19 26 gauge wire with a maximum insulation of 0 082 inches Cut off stripped ends prior to terminating Rear View of the K 1200 CO Line Yellow...

Page 4: ...netic Lock 120V AC 120V AC 120V AC D Using the K 1200 with a C 3000 For a No CO installation a Viking C 3000 No CO controller can be used with the K 1200 Note the K 1200 will need to be programmed on a separate CO line or use the Viking DLE 200B The door strike can be controlled by the K 1200 or the internal relay on the C 3000 just be sure to disable the door strike feature in the other unit The ...

Page 5: ...ing programming If this happens check to see that DIP switch 1 is ON so the unit is set to answer incoming calls Then turn DIP switch 4 ON to allow accessing programming without the security code Call the line attached to the K 1200 With the phone ringing press the 0 button on the K 1200 keypad The K 1200 should answer the line and you should hear two beeps indicating that you are in the programmi...

Page 6: ...git Each of the speed dial positions 01 to 12 pertain to the corresponding button on the front of the K 1200 The button 0 uses position 10 the Q uses position 11 and the uses position 12 To program a speed dial position enter programming see section A then enter the desired number followed by the selected position To clear a position only enter a followed by the position number with out any preced...

Page 7: ...occurs enter 33 when in programming This will disable return to dial tone feature and stop the K 1200 from hanging up prematurely To enable this feature enter 32 when in programming N Hang Up on Return to Dial Tone See Operation for a functional description of this feature Tenant Initiated Entry is disabled by default To enable it enter programming see Programming section A Enter 38 Also DIP switc...

Page 8: ...lved Connection to Party Line Service is subject to State Tariffs Contact the state public utility commission public service commission or corporation commission for information WHEN PROGRAMMING EMERGENCY NUMBERS AND OR MAKING TEST CALLS TO EMERGENCY NUMBERS Remain on the line and briefly explain to the dispatcher the reason for the call Perform such activities in the off peak hours such as early ...

Reviews: