1.16.1 Port Status
1.16.2 Status
1.16.3 Class/Error
Value
1.16.4 Remote PD
Type
1.16.5 Voltage
1.16.6 Current
1.16.7 Power
1.16.8 Temperature
1.17.1 Statistics
1.17.2 Overload
Counter
1.17.3 Short Counter
1.17.4 Power Denied
Counter
1.17.5 Invalid
Detection Counter
1.17.6 Reset Statistics
Check to enable polling of port. Uncheck to disable polling.
This shows the port status. The status is color coded for easy identification.
“Green” for delivering.
“Blue” for searching.
“Gray” for disabled.
“Yellow” for Requesting Power.
“Orange” for Test mode.
“Red” for Fault.
This shows the class being detected in case of normal operation. It also shows the
error value in case of a fault condition.
This shows the type of PD (powered device) detected by the Midspan. If there is no
PD detected, the Midspan will not
automatically apply power.
This shows the output voltage of the port.
This shows the DC current being delivered.
This shows the power being delivered.
This shows the junction temperature of the controller chip of that specific port.
This shows how many times the port has been in overload status.
This shows how many times the port has been shorted.
This shows how many times the port has denied power to loads.
This shows how many times the port has detected an invalid load.
This will reset all port statistics.