23
1.13.2 Classification
1.13.3 Violation Type
1.13.4 Max Power
1.13.5 Power Inrush
Control
1.13.6 Disable
1.13.7 Enable
1.13.8 Force Power
1.13.9 Select All
1.13.10 Apply
Choose the classification type for selected ports:
“Bypass” for ignoring classification.
“.3AF/AT” for IEEE 802.3af/at classification signature
Choose the violation type for selected ports during delivering state:
“None” for bypassing violation checking.
“Class Based” for limiting power based on the classification results. If
classification is bypassed, then “Class-0” will be used in Normal Mode and
“ILIM/ICUT” values in high power mode.
“User Defined” for limiting power based on user defined value.
Choose the user defined power value. This value is used if the “Violation Type” is
“User Defined”.
Choose the “Power Inrush Control” mode of selected port:
“Normal” for IEEE 802.3af mode.
“High Inrush” for legacy devices, which require more than 15.4W. For the
port to deliver more than 15.4W appropriately, the ILIM/ICUT value needs
to be selected and classification needs to be bypassed.
“Pre 802.3at” for devices supporting 802.3at. Use this mode to deliver
more than 15.4W. Appropriate ILIM/ICUT value should be selected.
Check this box to disable selected ports. Check boxes “Disable”, “Enable” and “Force
Power” are mutually exclusive.
Checking this box will enable selected ports.
Check this box to force the selected port to “Power On”. This will bypass detection,
classification, and power management steps, and no violation will be honored.
Check “Select All” to select all ports. Otherwise, each port number must be
individually selected.
This button must be clicked to load the user selected configuration onto the selected
ports.